|
3b70fa6dcc
|
Add bcm iginition readout
|
2022-04-21 19:55:59 +02:00 |
|
|
8e2807d8aa
|
Disable tpms alert logging, but still not tested
|
2022-04-21 19:49:36 +02:00 |
|
|
06595b54a2
|
Remove iginition detection because not working too
|
2022-04-21 19:48:26 +02:00 |
|
|
c440602ada
|
Debug hood detection
|
2022-04-21 19:46:23 +02:00 |
|
|
304d2219fe
|
Fix charge power calculation and add pf measurements
|
2022-04-21 19:45:39 +02:00 |
|
|
63dd1e92c8
|
Fix web config
|
2022-04-21 01:11:06 +02:00 |
|
|
79741acc0f
|
Readd charge efficiency
|
2022-04-21 01:03:56 +02:00 |
|
|
214638eb9d
|
Fix web, fix user soc
|
2022-04-21 00:51:04 +02:00 |
|
|
869138633f
|
Add switch bedween user and lbc SOC
|
2022-04-21 00:15:39 +02:00 |
|
|
061746588f
|
Change pollstate naming
|
2022-04-20 23:57:48 +02:00 |
|
|
6a6bffced2
|
Add powerfactor to charge log for debug
|
2022-04-20 23:53:02 +02:00 |
|
|
3eeddf0db4
|
Change charge logging
|
2022-04-20 23:49:17 +02:00 |
|
|
6300314851
|
Add powerfactor, testing needed
|
2022-04-20 23:45:03 +02:00 |
|
|
6195129baa
|
Add ambient air pressure
|
2022-04-20 23:26:00 +02:00 |
|
|
a7d3c42791
|
Implement BMS trip energy calculation
|
2022-04-20 22:56:03 +02:00 |
|
|
ede1e57238
|
Add metrics for using BMS as trip energy counter
|
2022-04-20 21:46:05 +02:00 |
|
|
5b510f7c50
|
Fix metric namings
|
2022-04-20 21:36:52 +02:00 |
|
|
fcd3f12b5b
|
Cleap up, remove other vehicles because I am not maintaining it
|
2022-04-20 21:21:34 +02:00 |
|
|
6f87132aee
|
Fix batt usage calc, wrong sign
|
2022-04-20 07:55:28 +00:00 |
|
|
53e66b9547
|
Accidentally changed wrong file in the past
|
2022-04-20 07:31:39 +00:00 |
|
|
d4bfaff4d2
|
Web: remove extern variable
|
2022-04-20 01:18:26 +02:00 |
|
|
987427243c
|
Fix complie
|
2022-04-20 01:16:16 +02:00 |
|
|
df9ac30333
|
Fix est calc
|
2022-04-20 01:08:54 +02:00 |
|
|
56f716bbae
|
Add TDB reference
|
2022-04-20 00:46:24 +02:00 |
|
|
a1cd7dd61f
|
Fix ConfigChange, Debug Est Range
|
2022-04-20 00:39:20 +02:00 |
|
|
0323fc19fe
|
Fix web settings
|
2022-04-19 23:34:11 +02:00 |
|
|
449874caa7
|
Init standard metrics to supress push not. at boot up
|
2022-04-19 23:14:39 +02:00 |
|
|
bfe984bb78
|
Change compressor hd pressure to BAR, remove debug msg
|
2022-04-19 23:01:03 +02:00 |
|
|
86a08180e5
|
Optimize Pollrates
|
2022-04-19 22:57:33 +02:00 |
|
|
c7995e9bcf
|
BCM remove debug from working PIDs
Change ignition on PID
|
2022-04-19 22:49:07 +02:00 |
|
|
262ba88322
|
Debug trip counter from cluster
|
2022-04-19 22:44:31 +02:00 |
|
|
1fa767a5f1
|
Fix energy counter
|
2022-04-19 22:43:20 +02:00 |
|
|
19106cdd89
|
Fix pollstates
|
2022-04-19 02:19:55 +02:00 |
|
|
313ca651b4
|
fix minor issues
|
2022-04-18 23:31:52 +02:00 |
|
|
9a01e75f02
|
Fix readouts
|
2022-04-18 22:42:43 +02:00 |
|
|
5eb8a6fbf0
|
Fix Estimated
|
2022-04-18 20:58:15 +02:00 |
|
|
80791a2b9b
|
Bugfix
|
2022-04-18 20:48:43 +02:00 |
|
|
5207fec284
|
Add cluster trip
|
2022-04-18 20:26:15 +02:00 |
|
|
0a9eee465c
|
Bugfixes
|
2022-04-18 19:21:09 +02:00 |
|
|
5734e81f03
|
Try readouts for doors
|
2022-04-18 17:41:15 +02:00 |
|
|
1ec01ca1ac
|
Web radio button (fix needed)
|
2022-04-18 14:32:33 +02:00 |
|
|
9b189303a1
|
Try CAN_UINT for Key Lock
|
2022-04-18 13:39:11 +02:00 |
|
|
7b6e8e3e03
|
Fix TPMS readout
|
2022-04-18 13:25:47 +02:00 |
|
|
0e32024133
|
Add battery capacity web chooser, minor fixes, add trip counter
|
2022-04-18 03:13:01 +02:00 |
|
|
c8cbbfe5a0
|
Add hvac compressor PIDs
|
2022-04-18 02:16:56 +02:00 |
|
|
6a2e6dd765
|
Fix pollstates
|
2022-04-18 01:18:02 +02:00 |
|
|
f4c78f831e
|
Change env_on behavior, later use CAN direct
|
2022-04-18 01:15:42 +02:00 |
|
|
3a7340ecf8
|
Cosmetic set 12v current to zero on shutdown
|
2022-04-18 01:11:40 +02:00 |
|
|
61e3bfbced
|
Add lock and door states
|
2022-04-18 01:07:32 +02:00 |
|
|
aabe4897a2
|
Remove custom mains current metric, because StandardMetric
|
2022-04-18 00:37:30 +02:00 |
|
|
a9422155c2
|
Slow down battery pack polls
|
2022-04-18 00:33:45 +02:00 |
|
|
df0642b78f
|
Implement vehicle running aka on over BCM, testing needed
|
2022-04-18 00:32:13 +02:00 |
|
|
e451ec9c79
|
Add TPMS alerts
|
2022-04-18 00:27:30 +02:00 |
|
|
ed04762d08
|
Fix cabin temp readout
|
2022-04-17 23:17:42 +02:00 |
|
|
c812cea7a5
|
Fix readouts
|
2022-04-17 14:25:03 +02:00 |
|
|
3350c0ff1c
|
Disable logging BMS
|
2022-04-17 14:14:33 +02:00 |
|
|
eb00521257
|
Faster poll rate
|
2022-04-17 13:53:23 +02:00 |
|
|
2ac9a78008
|
Fix values after test run
|
2022-04-17 13:48:30 +02:00 |
|
|
dfd8158a13
|
Fix adress of controllers
|
2022-04-17 13:15:50 +02:00 |
|
|
cc757e4c66
|
Add charging statistics and efficiency
|
2022-04-17 11:17:54 +02:00 |
|
|
e3f32ce7e6
|
Add AC charger values
|
2022-04-17 10:33:20 +02:00 |
|
|
78388403b4
|
Change HVAC poll rate, fix logging BCM
|
2022-04-17 10:09:40 +02:00 |
|
|
e1b674192c
|
Add TPMS readout
|
2022-04-17 10:07:38 +02:00 |
|
|
2685cd972a
|
Fix device adresses
|
2022-04-17 10:02:49 +02:00 |
|
|
41d76bc136
|
Disable logging of raw CAN packets
|
2022-04-17 09:53:08 +02:00 |
|
|
ef2fb35e05
|
Add calc for battery power
|
2022-04-17 09:43:20 +02:00 |
|
|
25afba9d8f
|
Change motor rpm from INV to EVC because
of strange values
|
2022-04-17 09:31:26 +02:00 |
|
|
1e33812c92
|
Change LBC battery stats for later calculations
|
2022-04-17 09:07:18 +02:00 |
|
|
1c9048a4e9
|
Implement charge type
|
2022-04-17 09:03:11 +02:00 |
|
|
4d94ee7bcd
|
Implement vehicle speed
|
2022-04-17 08:54:24 +02:00 |
|
|
fdb314b2f5
|
Poll charge state when off, because freeframes unreliable
and important PID
|
2022-04-17 08:49:10 +02:00 |
|
|
937ea9c3ae
|
Change cable plug behavior
|
2022-04-17 08:25:32 +02:00 |
|
|
749fe7d79a
|
Disable logging for succesful PIDs
|
2022-04-17 08:21:37 +02:00 |
|
|
5c29f7e2e8
|
Fix INV power calculation
|
2022-04-17 08:08:25 +02:00 |
|
|
b1baa96d2b
|
Fix driving by using inverter status
|
2022-04-17 01:22:14 +02:00 |
|
|
2b4d5f5294
|
Fix tpms, fix double phrases
|
2022-04-17 01:16:40 +02:00 |
|
|
6c5bbda6a0
|
TPMS implement OVMS-way
|
2022-04-17 01:12:01 +02:00 |
|
|
6da38c3b9b
|
Add one tpms pressure sensor
|
2022-04-17 01:08:27 +02:00 |
|
|
9f993bfc4d
|
Change charge on off behavior
|
2022-04-17 01:03:46 +02:00 |
|
|
c4bda8ee68
|
Remove unecessary polls
|
2022-04-17 00:54:10 +02:00 |
|
|
4b28894b3a
|
Poll odometer, because Freeframes are unreliable
|
2022-04-17 00:46:34 +02:00 |
|
|
d483b1818f
|
Add EVC messages for replacing Free Frames.
Change to EXTFRAME for other Devices.
|
2022-04-17 00:44:39 +02:00 |
|
|
bb6c1a04f0
|
Lower polling rate for debug
|
2022-04-17 00:21:20 +02:00 |
|
|
3a042c4656
|
Fix bms cell voltage numbering
|
2022-04-17 00:18:26 +02:00 |
|
|
02fc67a5fe
|
Stop Poll after bootup
|
2022-04-17 00:02:50 +02:00 |
|
|
a5ce9c2d2d
|
bms temp count
|
2022-04-17 00:02:03 +02:00 |
|
|
cf5f1572c6
|
Log BMS because no values shown
|
2022-04-16 23:34:54 +02:00 |
|
|
3432b69207
|
Change charge commands because status is showing not charging
|
2022-04-16 23:11:29 +02:00 |
|
|
e77d36e85b
|
Fix compile errors
|
2022-04-16 22:34:58 +02:00 |
|
|
e3b9cb8883
|
Set ISOTP STD
|
2022-04-16 22:28:37 +02:00 |
|
|
c1dc4a5c9b
|
Fix PIDs again
|
2022-04-16 22:28:00 +02:00 |
|
|
c6d61ebaa8
|
Try to read UCM with ISOTP STD
|
2022-04-16 22:07:54 +02:00 |
|
|
8cbac77377
|
Try to initiate Debug session to get BCM to read out
|
2022-04-16 21:54:07 +02:00 |
|
|
a3df502cad
|
Fix EVC and INV pids. Add OBD Debug session for HVAC and UCM
|
2022-04-16 21:43:38 +02:00 |
|
|
6877d46549
|
Fix LBC temperatures
|
2022-04-16 21:32:07 +02:00 |
|
|
afce8ca44b
|
Fix LBC debug messages and remove packet debug
|
2022-04-16 21:22:38 +02:00 |
|
|
7deadbd711
|
Fix LBC debug messages and remove packet debug
|
2022-04-16 21:22:20 +02:00 |
|
|
982f1d4e0e
|
Fix mt_bus_awake
|
2022-04-16 20:40:40 +02:00 |
|
|
c5aa9c4d93
|
Log fix
|
2022-04-16 20:06:22 +02:00 |
|
|
379c0d11de
|
Add logging of bus state because of realibility problems of car state
|
2022-04-16 19:55:43 +02:00 |
|
|
a2f5a09069
|
Fix startup bus activity and LBC logging
|
2022-04-16 19:44:44 +02:00 |
|
|
3fbcb7015f
|
Fix car states
|
2022-04-16 16:39:31 +02:00 |
|
|
7418f08f6f
|
Fix temp PIDs and BMS logging
|
2022-04-16 15:32:15 +02:00 |
|
|
7d3889fbcc
|
Implement car on of driving charging method depending on some free frames
|
2022-04-16 14:41:36 +02:00 |
|
|
464a2e4b39
|
Remove bus awake from poll
|
2022-04-16 13:41:45 +02:00 |
|
|
87d2b7ef53
|
Fix BMS web page
|
2022-04-16 06:00:59 +02:00 |
|
|
5e37f0d2ba
|
FIx server in Init assistant
|
2022-04-16 05:51:01 +02:00 |
|
|
cf81cf2419
|
Fix cert
|
2022-04-16 05:40:19 +02:00 |
|
|
91147a1cba
|
Fix own ca and server
|
2022-04-16 05:18:28 +02:00 |
|
|
dbfdc04aac
|
Fix PIDs and add cell voltage and temperature and BMS webpage
|
2022-04-16 04:51:35 +02:00 |
|
|
d49ad6f5ed
|
Add other vehicle module because of crashing
|
2022-04-16 02:47:00 +02:00 |
|
|
71eaf7e713
|
Start from scratch becaus of crashing
|
2022-04-15 16:17:12 +02:00 |
|
|
4794b21784
|
Clean up and restruct files
|
2022-04-15 00:35:23 +02:00 |
|
|
3aae5c16a8
|
Fix calculation on PIDs
|
2022-04-14 22:54:52 +02:00 |
|
|
81319297ec
|
Fix EVC pids
|
2022-04-14 17:55:06 +02:00 |
|
|
3e086fc99b
|
Clean up and fix inverter pids
|
2022-04-14 17:41:40 +02:00 |
|
|
d81f43481b
|
minor fixes
|
2022-04-14 02:06:36 +02:00 |
|
|
4a36ac21e2
|
Set bus state to enable on bootup
|
2022-04-14 01:48:06 +02:00 |
|
|
1475aacf45
|
Add more pids from hvac
|
2022-04-14 01:38:32 +02:00 |
|
|
01df5e29bb
|
Remove navigation
|
2022-04-14 01:11:52 +02:00 |
|
|
8356269dd6
|
Add PIDs for battery and inverter
|
2022-04-14 01:11:37 +02:00 |
|
|
f2ca6c0f18
|
Add units
|
2022-04-13 23:43:05 +02:00 |
|
|
6d6e4cc398
|
Add inverter temperature
|
2022-04-13 23:35:46 +02:00 |
|
|
17149d7b7c
|
Fix inverter status
|
2022-04-13 22:47:27 +02:00 |
|
|
4904453b00
|
Fix battery statistics
|
2022-04-13 22:46:21 +02:00 |
|
|
67b8238b29
|
Add battery average temperature
|
2022-04-13 22:37:45 +02:00 |
|
|
0387bf2d6f
|
Fix temperature readings, misinterpreted DDT2000 XML
|
2022-04-13 22:31:01 +02:00 |
|
|
b0f76d800b
|
Implement Car On Off behavior
|
2022-04-13 22:16:04 +02:00 |
|
|
ac65f65172
|
Remove unused devices
|
2022-04-12 23:37:59 +02:00 |
|
|
66548a1e80
|
Fix hyphen
|
2022-04-12 23:36:26 +02:00 |
|
|
d904badf77
|
Correct and add more PIDs
|
2022-04-12 23:30:29 +02:00 |
|
|
9548b95ee0
|
Fixing PIDs
|
2022-04-12 22:06:20 +02:00 |
|
|
85356d65d9
|
Log format typo
|
2022-04-12 21:33:26 +02:00 |
|
|
8d9fc71f58
|
More debugging messages
|
2022-04-12 21:28:46 +02:00 |
|
|
087b39197b
|
Add UCC with volume for further debugging, because not EXTFRAME request gets processed
|
2022-04-12 20:37:40 +02:00 |
|
|
2ea9645a3a
|
Modify polltimes and throttle for easier debugging
|
2022-04-12 20:01:59 +02:00 |
|
|
418ed4be9b
|
Log every packet in verbose
|
2022-04-12 19:57:30 +02:00 |
|
|
925f8a5163
|
Revert back to unit16 PID like original, misinterpreted addresses
|
2022-04-12 19:53:42 +02:00 |
|
|
b393183b4a
|
Fix PID addresses
|
2022-04-12 19:19:55 +02:00 |
|
|
00cfe30856
|
Revert back to Extframe
|
2022-04-12 02:32:56 +02:00 |
|
|
0dfdbe9595
|
Change obd session and isotp addressing.
|
2022-04-12 02:21:29 +02:00 |
|
|
5c3623b77b
|
Set static awake because of polling only.
|
2022-04-12 01:58:08 +02:00 |
|
|
3aae954833
|
Formatting fix
|
2022-04-12 01:43:58 +02:00 |
|
|
8c921e45d1
|
Fix typo
|
2022-04-12 01:42:50 +02:00 |
|
|
a7dba9845b
|
Add OBD2 Extended Diag Session
|
2022-04-12 01:41:19 +02:00 |
|
|
04794f2f86
|
Fix compile ph2 vehicle module and speed up build by disabling other modules
|
2022-04-12 01:26:13 +02:00 |
|
|
f6c805db1a
|
First try some PIDs
|
2022-04-12 00:09:57 +02:00 |
|
|
2298cf235c
|
Add ph2 to default sdkconfig
|
2022-04-10 22:43:29 +02:00 |
|
|
655176c238
|
Clean up
|
2022-04-10 20:30:54 +02:00 |
|
|
0f7622646c
|
Typo fix
|
2022-04-09 05:02:50 +02:00 |
|