Add inverter temperature

This commit is contained in:
Carsten Schmiemann 2022-04-13 23:35:46 +02:00
parent 17149d7b7c
commit 6d6e4cc398

View file

@ -86,6 +86,7 @@ static const OvmsVehicle::poll_pid_t renault_zoe_polls[] = {
//Motor Inverter
//{ 0x18dadff1, 0x18daf1df, VEHICLE_POLL_TYPE_OBDIISESSION, SESSION_EXTDIAG, { 60, 60, 60, 60 }, 0, ISOTP_EXTFRAME }, // OBD Extended Diagnostic Session
{ 0x18dadff1, 0x18daf1df, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x700C, { 0, 10, 3, 10 }, 0, ISOTP_EXTFRAME }, // Inverter temperature
{ 0x18dadff1, 0x18daf1df, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x700F, { 0, 10, 3, 10 }, 0, ISOTP_EXTFRAME }, // Stator Temperature 1
{ 0x18dadff1, 0x18daf1df, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x7010, { 0, 10, 3, 10 }, 0, ISOTP_EXTFRAME }, // Stator Temperature 2
@ -230,13 +231,18 @@ void OvmsVehicleRenaultZoePh2::IncomingPollReply(canbus* bus, uint16_t type, uin
*/
void OvmsVehicleRenaultZoePh2::IncomingINV(uint16_t type, uint16_t pid, const char* data, uint16_t len) {
switch (pid) {
case 0x700F: { // Motor temperature
case 0x700C: { // Inverter temperature
StandardMetrics.ms_v_inv_temp->SetValue(float((CAN_UINT(0) - 40)), Celcius);
ESP_LOGD(TAG, "700C INV ms_v_inv_temp: %f", float((CAN_UINT(0) - 40)));
break;
}
case 0x700F: { // Motor, Stator1 temperature
StandardMetrics.ms_v_mot_temp->SetValue(float((CAN_UINT(0) - 40)), Celcius);
mt_mot_temp_stator1->SetValue(float((CAN_UINT(0) - 40)), Celcius);
ESP_LOGD(TAG, "700F INV ms_v_mot_temp: %f", float((CAN_UINT(0) - 40)));
break;
}
case 0x7010: {
case 0x7010: { // Stator 2 temperature
mt_mot_temp_stator2->SetValue(float((CAN_UINT(0) - 40)), Celcius);
ESP_LOGD(TAG, "7010 INV mt_mot_temp_stator2: %f", float((CAN_UINT(0) - 40)));
break;
@ -299,8 +305,8 @@ void OvmsVehicleRenaultZoePh2::IncomingEVC(uint16_t type, uint16_t pid, const ch
ESP_LOGD(TAG, "7ec inv temp: %d", CAN_BYTE(0) - 40);
break;
}
case 0xF446: { //Ambient temperature
StandardMetrics.ms_v_env_temp->SetValue((float) (CAN_UINT(0) - 40) * 0.01);
case 0xF446: { // Ambient temperature
StandardMetrics.ms_v_env_temp->SetValue((float) (CAN_UINT(0) - 40) * 0.01, Celcius);
ESP_LOGD(TAG, "F446 EVC ms_v_env_temp: %f", (CAN_UINT(0) - 40) * 0.01);
break;
}
@ -374,7 +380,7 @@ void OvmsVehicleRenaultZoePh2::IncomingLBC(uint16_t type, uint16_t pid, const ch
break;
}
case 0x9012: { //Battery average temperature
StandardMetrics.ms_v_bat_temp->SetValue((float) ((CAN_UINT(0) - 40));
StandardMetrics.ms_v_bat_temp->SetValue((float) (CAN_UINT(0) - 40));
ESP_LOGD(TAG, "9012 LBC ms_v_bat_temp: %f", ((CAN_UINT(0) - 40));
break;
}