---- ✂️ ---- ⚡📉 Health warning: voltage The voltage on MikroTik jumped more than 10%. old value: 16.2V new value: 12.4V ---- ✂️ ---- 🔥 Health warning: temperature The temperature on MikroTik is above threshold: 51°C ---- ✂️ ---- ✅ Health recovery: temperature The temperature on MikroTik dropped below threshold: 47°C ---- ✂️ ---- ❌ Health warning: psu1-state The power supply unit 'psu1-state' on MikroTik failed! ---- ✂️ ---- ✅ Health recovery: psu1-state The power supply unit 'psu1-state' on MikroTik recovered! ---- ✂️ ----
66 lines
2 KiB
Markdown
66 lines
2 KiB
Markdown
Notify about health state
|
||
=========================
|
||
|
||
[◀ Go back to main README](../README.md)
|
||
|
||
> ℹ️ **Info**: This script can not be used on its own but requires the base
|
||
> installation. See [main README](../README.md) for details.
|
||
|
||
Description
|
||
-----------
|
||
|
||
This script is run from scheduler periodically, sending notification on
|
||
health related events:
|
||
|
||
* voltage jumps up or down more than configured threshold or drops below limit
|
||
* power supply failed or recovered
|
||
* temperature is above or below threshold
|
||
|
||
Note that bad initial state will not trigger an event.
|
||
|
||
Only sensors available in hardware can be checked. See what your
|
||
hardware supports:
|
||
|
||
/system/health/print;
|
||
|
||
### Sample notifications
|
||
|
||
#### Voltage
|
||
|
||
![check-health notification voltage](check-health.d/notification-01-voltage.avif)
|
||
|
||
#### Temperature
|
||
|
||
![check-health notification](check-health.d/notification-02-temperature-high.avif)
|
||
![check-health notification](check-health.d/notification-03-temperature-ok.avif)
|
||
|
||
#### PSU state
|
||
|
||
![check-health notification](check-health.d/notification-04-psu-fail.avif)
|
||
![check-health notification](check-health.d/notification-05-psu-ok.avif)
|
||
|
||
Requirements and installation
|
||
-----------------------------
|
||
|
||
Just install the script and create a scheduler:
|
||
|
||
$ScriptInstallUpdate check-health;
|
||
/system/scheduler/add interval=1m name=check-health on-event="/system/script/run check-health;" start-time=startup;
|
||
|
||
Configuration
|
||
-------------
|
||
|
||
The configuration goes to `global-config-overlay`, these are the parameters:
|
||
|
||
* `CheckHealthTemperature`: an array specifying temperature thresholds for sensors
|
||
* `CheckHealthVoltageLow`: value (in volt*10) giving a hard lower limit
|
||
* `CheckHealthVoltagePercent`: percentage value to trigger voltage jumps
|
||
|
||
Also notification settings are required for
|
||
[e-mail](mod/notification-email.md),
|
||
[matrix](mod/notification-matrix.md) and/or
|
||
[telegram](mod/notification-telegram.md).
|
||
|
||
---
|
||