1. configs are not functional
* decorator will be executed when search case, need to set default config before search case.
2. fix DUT encode/decode errors
* python3 serial don't support write string/unicode, need to convert to bytes first.
* python2 string could failed to encode/decode non-acsii chars
3. fix bug that log folder not created
4. fix bug that test suite name is not correctly passed:
* the keyward arg should be `test_suite_name` not `test_name`
5. fix bug that test stopped on failed case
6. fix DUT `read` don't return all data cache
* `_DataCache.get_data` should first copy all data from queue to data cache and then return to user.
7. fix bug that `expect_all` failed even all expected item passed
8. optimize error info for expect
* print pattern for regular expression when match failed
9. fix bug that set default config doesn't work
1. Attenuator: control programmable attenuator
2. PowerControl: control APC PDU to power on/off devices
3. LineChart: use matplotlib to draw line chart
This fixes errors logged on the console: sdmmc_req:
handle_idle_state_events unhandled: 00000004 00000000
The issue happens if "data done" event occurs before "command done".
State machine code did not check *which* event occurred in
SENDING_CMD state, and went to IDLE or SENDING_DATA state on any
non-error event. In this case, we can't process "data done" event
until command has completed. This change introduces "unhandled event"
mask, which is carried over from one run of process_events to the
other. This allows waiting for the "command done" event to complete,
and then process "data done" event.
Ref TW17126.
CMD53 in byte mode supports transfers of any number of bytes between 1
and 512. This change removes limitation that the number of bytes must
be divisible by 4. Host quirk, that such transfers must be split into
two commands (one for the aligned part and the other one for
unaligned) is taken into account.
When two CPUs read the area of the DPORT and the area of the APB, the result is corrupted for the CPU that read the APB area.
And another CPU has valid data.
The method of eliminating this error.
Before reading the registers of the DPORT, make a preliminary reading of the APB register.
In this case, the joint access of the two CPUs to the registers of the APB and the DPORT is successful.
As of now, when Bluetooth debugs are enabled, all the messages are
mapped to BT_PRINTF which is mapped to ESP_LOGE. Hence, make monitor
shows all logs in red color which might lead to missing the actual
errors
This patch maps the Bluetooth messages to appropriate ESP_LOG* messages
and improves readability.
Also, make the BT trace level be configurable in menuconfig, so that
each layer of bt trace can be enabled/disabled.
Finally, add debug log control for BTC, OSI, BLUFI and clear up
Bluetooth debug logs.
So, with this the method of enabling Bluetooth logs is as follows:
1. make menuconfig -> Component config -> Bluetooth -> Bluedroid Enable
-> BT DEBUG LOG LEVEL -> set trace level for every layer of BT
Signed-off-by: Hrishikesh Dhayagude <hrishi@espressif.com>
If the allocated interrupt list is not empty and the new item will be inserted
as the header of the list, insert_vector_desc() causes crash because pre is
null. This commit fix this issue.
1. Fix the duty fade check issue reported from https://github.com/espressif/esp-idf/issues/1914
2. Fix the duty overflow issue when duty_scale is set to 1.
3. Fix the duty fade error when a fade operation is under way. We must configure a new duty setting after the previous fade operation has finished due to hardware limit.
4. Add thread-safe version APIs to set duty and fade.
5. Correct the duty range in driver.