#!rsc
|
|
# RouterOS script: check-health
|
|
# Copyright (c) 2019-2020 Christian Hesse <mail@eworm.de>
|
|
# https://git.eworm.de/cgit/routeros-scripts/about/COPYING.md
|
|
#
|
|
# check for RouterOS health state
|
|
# https://git.eworm.de/cgit/routeros-scripts/about/doc/check-health.md
|
|
|
|
:global CheckHealthLast;
|
|
:global CheckHealthTemperature;
|
|
:global CheckHealthVoltagePercent;
|
|
:global Identity;
|
|
|
|
:global LogPrintExit;
|
|
:global SendNotification;
|
|
|
|
:local FormatVoltage do={
|
|
:local Voltage [ :tonum $1 ];
|
|
:return (($Voltage / 10) . "." . ($Voltage % ($Voltage / 10 * 10)) . "V");
|
|
}
|
|
|
|
:local CheckHealthCurrent [ / system health get ];
|
|
|
|
:foreach Voltage in={ "battery"; "psu1-voltage"; "psu2-voltage"; "voltage" } do={
|
|
:if ([ :typeof ($CheckHealthLast->$Voltage) ] = "num" && \
|
|
[ :typeof ($CheckHealthCurrent->$Voltage) ] = "num") do={
|
|
:if ($CheckHealthLast->$Voltage * (100 + $CheckHealthVoltagePercent) < $CheckHealthCurrent->$Voltage * 100 || \
|
|
$CheckHealthLast->$Voltage * 100 > $CheckHealthCurrent->$Voltage * (100 + $CheckHealthVoltagePercent)) do={
|
|
$SendNotification ("Health warning: " . $Voltage) \
|
|
("The " . $Voltage . " on " . $Identity . " jumped more than " . $CheckHealthVoltagePercent . "%.\n\n" . \
|
|
"old value: " . [ $FormatVoltage ($CheckHealthLast->$Voltage) ] . "\n" . \
|
|
"new value: " . [ $FormatVoltage ($CheckHealthCurrent->$Voltage) ]);
|
|
}
|
|
}
|
|
}
|
|
|
|
:foreach PSU in={ "psu1"; "psu2" } do={
|
|
:if ([ :typeof ($CheckHealthLast->($PSU . "-state")) ] = "str" && \
|
|
[ :typeof ($CheckHealthCurrent->($PSU . "-state")) ] = "str") do={
|
|
:if ($CheckHealthLast->($PSU . "-state") = "ok" && \
|
|
$CheckHealthCurrent->($PSU . "-state") != "ok") do={
|
|
$SendNotification ("Health warning: \E2\9D\8C " . $PSU . " state") \
|
|
("The power supply unit '" . $PSU . "' on " . $Identity . " failed!");
|
|
}
|
|
:if ($CheckHealthLast->($PSU . "-state") != "ok" && \
|
|
$CheckHealthCurrent->($PSU . "-state") = "ok") do={
|
|
$SendNotification ("Health recovery: \E2\9C\85 " . $PSU . " state") \
|
|
("The power supply unit '" . $PSU . "' on " . $Identity . " recovered!");
|
|
}
|
|
}
|
|
}
|
|
|
|
:foreach Temperature in={ "temperature"; "cpu-temperature"; "board-temperature1"; "board-temperature2" } do={
|
|
:if ([ :typeof ($CheckHealthLast->$Temperature) ] = "num" && \
|
|
[ :typeof ($CheckHealthCurrent->$Temperature) ] = "num") do={
|
|
:if ([ :typeof ($CheckHealthTemperature->$Temperature) ] != "num" ) do={
|
|
$LogPrintExit warning ("No threshold given for " . $Temperature . ", assuming 50C.") false;
|
|
:set ($CheckHealthTemperature->$Temperature) 50;
|
|
}
|
|
:if ($CheckHealthLast->$Temperature <= $CheckHealthTemperature->$Temperature && \
|
|
$CheckHealthCurrent->$Temperature > $CheckHealthTemperature->$Temperature) do={
|
|
$SendNotification ("Health warning: \F0\9F\94\A5 " . $Temperature) \
|
|
("The " . $Temperature . " on " . $Identity . " is above threshold: " . \
|
|
$CheckHealthCurrent->$Temperature . "\C2\B0" . "C");
|
|
}
|
|
:if ($CheckHealthLast->$Temperature > $CheckHealthTemperature->$Temperature && \
|
|
$CheckHealthCurrent->$Temperature <= $CheckHealthTemperature->$Temperature) do={
|
|
$SendNotification ("Health recovery: \E2\9C\85 " . $Temperature) \
|
|
("The " . $Temperature . " on " . $Identity . " dropped below threshold: " . \
|
|
$CheckHealthCurrent->$Temperature . "\C2\B0" . "C");
|
|
}
|
|
}
|
|
}
|
|
|
|
:set CheckHealthLast $CheckHealthCurrent;
|