OVMS3/Reference/ZOE_Ph2/FCAM_Tests.csv

2.8 KiB

100Device and failure type ODB codding
201General Electrical Failure
302General signal failure
403FM (Frequency Modulated) / PWM (Pulse Width Modulated) Failures
504System Internal Failures
605System Programming Failures
706Algorithm Based Failures
807Mechanical Failures
908Bus Signal / Message Failures
1009Component Failures
1111circuit short to ground
1212circuit short to battery
1313circuit open
1414circuit short to ground or open
1515circuit short to battery or open
1616circuit voltage below threshold
1717circuit voltage above threshold
1818circuit current below threshold
1919circuit current above threshold
201Acircuit resistance below threshold
211Bcircuit resistance above threshold
221Ccircuit voltage out of range
231Dcircuit current out of range
241Ecircuit resistance out of range
251Fcircuit intermittent
2621signal amplitude < minimum
2722signal amplitude > maximum
2823signal stuck low
2924signal stuck high
3025signal shape / waveform failure
3126signal rate of change below threshold
3227signal rate of change above threshold
3328signal bias level out of range / zero adjustment failure
3429signal signal invalid
352Fsignal erratic
3631no signal
3732signal low time < minimum
3833signal low time > maximum
3934signal high time < minimum
4035signal high time > maximum
4136signal frequency too low
4237signal frequency too high
4338signal frequency incorrect
4439incorrect has too few pulses
453Aincorrect has too many pulses
4641general checksum failure
4742general memory failure
4843special memory failure
4944data memory failure
5045program memory failure
5146calibration / parameter memory failure
5247watchdog / safety µC failure
5348supervision software failure
5449internal electronic failure
554Aincorrect component installed
564Bover temperature
5751not programmed
5852not activated
5953deactivated
6054missing calibration
6155not configured
6261signal calculation failure
6362signal compare failure
6463circuit / component protection time-out
6564signal plausibility failure
6665signal has too few transitions / events
6766signal has too many transitions / events
6867signal incorrect after event
6968event information
7071actuator stuck
7172actuator stuck open
7273actuator stuck closed
7374actuator slipping
7475emergency position not reachable
7576wrong mounting position
7677commanded position not reachable
7778alignment or adjustment incorrect
7879mechanical linkage failure
797Afluid leak or seal failure
807Blow fluid level
8181invalid serial data received
8282alive / sequence counter incorrect / not updated
8383value of signal protection calculation incorrect
8484signal below allowable range
8585signal above allowable range
8686signal invalid
8787missing message
8888bus off
898Ferratic
9091parametric
9192performance or incorrect operation
9293no operation
9394unexpected operation
9495incorrect assembly
9596component internal failure
9697Component or system operation obstructed or blocked
9798component or system over temperature