OVMS3/Reference/ZOE/UCH_Tests.csv

2.9 KiB

144data memory failure
262signal compare failure
363circuit / component protection time-out
464signal plausibility failure
565signal has too few transitions / events
661signal calculation failure
767signal incorrect after event
851not programmed
971actuator stuck
1072actuator stuck open
1145program memory failure
1255not configured
1354missing calibration
1452not activated
154Bover temperature
164Aincorrect component installed
1749internal electronic failure
1848supervision software failure
1947watchdog / safety µC failure
2046calibration / parameter memory failure
2173actuator stuck closed
2287missing message
2353deactivated
2443special memory failure
2598component or system over temperature
2697Component or system operation obstructed or blocked
2796component internal failure
2895incorrect assembly
2994unexpected operation
3093no operation
3192performance or incorrect operation
3291parametric
338Ferratic
3488bus off
3585signal above allowable range
3686signal invalid
3774actuator slipping
3884signal below allowable range
3983value of signal protection calculation incorrect
4082alive / sequence counter incorrect / not updated
4181invalid serial data received
427Blow fluid level
437Afluid leak or seal failure
4479mechanical linkage failure
4578alignment or adjustment incorrect
4677commanded position not reachable
4776wrong mounting position
4875emergency position not reachable
4966signal has too many transitions / events
500FVehicle manufacturer / System supplier specific
511Bcircuit resistance above threshold
521Acircuit resistance below threshold
5319circuit current above threshold
5418circuit current below threshold
5517circuit voltage above threshold
5616circuit voltage below threshold
5715circuit short to battery or open
5814circuit short to ground or open
5913circuit open
601Ccircuit voltage out of range
6111circuit short to ground
6209Component Failures
6308Bus Signal / Message Failures
6406Algorithm Based Failures
6505System Programming Failures
6604System Internal Failures
6703FM (Frequency Modulated) / PWM (Pulse Width Modulated) Failures
6802General signal failure
6901General Electrical Failure
7000Device and failure type ODB codding/ General Failure Information
7142general memory failure
7268event information
7312circuit short to battery
7435signal high time > maximum
7541general checksum failure
763Aincorrect has too many pulses
7707Mechanical Failures
781Dcircuit current out of range
7939incorrect has too few pulses
8038signal frequency incorrect
8136signal frequency too low
8234signal high time < minimum
8333signal low time > maximum
8432signal low time < minimum
8531no signal
8625signal shape / waveform failure
8721signal amplitude < minimum
8837signal frequency too high
892Fsignal erratic
901Fcircuit intermittent
9123signal stuck low
9224signal stuck high
9322signal amplitude > maximum
941Ecircuit resistance out of range
9526signal rate of change below threshold
9627signal rate of change above threshold
9728signal bias level out of range / zero adjustment failure
9829signal signal invalid