2.8 KiB
2.8 KiB
1 | 00 | Device and failure type ODB codding |
---|---|---|
2 | 01 | General Electrical Failure |
3 | 02 | General signal failure |
4 | 03 | FM / PWM (Pulse Width Modulated) Failures |
5 | 04 | System Internal Failures |
6 | 05 | System Programming Failures |
7 | 06 | Algorithm Based Failures |
8 | 07 | Mechanical Failures |
9 | 08 | Bus Signal / Message Failures |
10 | 09 | Component Failures |
11 | 11 | circuit short to ground |
12 | 12 | circuit short to battery |
13 | 13 | circuit open |
14 | 14 | circuit short to ground or open |
15 | 15 | circuit short to battery or open |
16 | 16 | circuit voltage below threshold |
17 | 17 | circuit voltage above threshold |
18 | 18 | circuit current below threshold |
19 | 19 | circuit current above threshold |
20 | 1A | circuit resistance below threshold |
21 | 1B | circuit resistance above threshold |
22 | 1C | circuit voltage out of range |
23 | 1D | circuit current out of range |
24 | 1E | circuit resistance out of range |
25 | 1F | circuit intermittent |
26 | 21 | signal amplitude < minimum |
27 | 22 | signal amplitude > maximum |
28 | 23 | signal stuck low |
29 | 24 | signal stuck high |
30 | 25 | signal shape / waveform failure |
31 | 26 | signal rate of change below threshold |
32 | 27 | signal rate of change above threshold |
33 | 28 | signal bias level out of range / zero adj. failure |
34 | 29 | signal signal invalid |
35 | 2F | signal erratic |
36 | 31 | no signal |
37 | 32 | signal low time < minimum |
38 | 33 | signal low time > maximum |
39 | 34 | signal high time < minimum |
40 | 35 | signal high time > maximum |
41 | 36 | signal frequency too low |
42 | 37 | signal frequency too high |
43 | 38 | signal frequency incorrect |
44 | 39 | incorrect has too few pulses |
45 | 3A | incorrect has too many pulses |
46 | 41 | general checksum failure |
47 | 42 | general memory failure |
48 | 43 | special memory failure |
49 | 44 | data memory failure |
50 | 45 | program memory failure |
51 | 46 | calibration / parameter memory failure |
52 | 47 | watchdog / safety µC failure |
53 | 48 | supervision software failure |
54 | 49 | internal electronic failure |
55 | 4A | incorrect component installed |
56 | 4B | over temperature |
57 | 51 | not programmed |
58 | 52 | not activated |
59 | 53 | deactivated |
60 | 54 | missing calibration |
61 | 55 | not configured |
62 | 61 | signal calculation failure |
63 | 62 | signal compare failure |
64 | 63 | circuit / component protection time-out |
65 | 64 | signal plausibility failure |
66 | 65 | signal has too few transitions / events |
67 | 66 | signal has too many transitions / events |
68 | 67 | signal incorrect after event |
69 | 68 | event information |
70 | 71 | actuator stuck |
71 | 72 | actuator stuck open |
72 | 73 | actuator stuck closed |
73 | 74 | actuator slipping |
74 | 75 | emergency position not reachable |
75 | 76 | wrong mounting position |
76 | 77 | commanded position not reachable |
77 | 78 | alignment or adjustment incorrect |
78 | 79 | mechanical linkage failure |
79 | 7A | fluid leak or seal failure |
80 | 7B | low fluid level |
81 | 81 | invalid serial data received |
82 | 82 | alive / sequence counter incorrect / not updated |
83 | 83 | value of signal protection calculation incorrect |
84 | 84 | signal below allowable range |
85 | 85 | signal above allowable range |
86 | 86 | signal invalid |
87 | 87 | missing message |
88 | 88 | bus off |
89 | 8F | erratic |
90 | 91 | parametric |
91 | 92 | performance or incorrect operation |
92 | 93 | no operation |
93 | 94 | unexpected operation |
94 | 95 | incorrect assembly |
95 | 96 | component internal failure |
96 | 97 | Component or sys. operation obstructed or blocked |
97 | 98 | component or system over temperature |