OVMS3/Reference/ZOE/EVC_Tests.csv

3.1 KiB

100Device and failure type ODB codding
201General Electrical Failure
302General signal failure
403FM (Frequency Modulated) / PWM (Pulse Width Modulated) Failures
504System Internal Failures
605System Programming Failures
706Algorithm Based Failures
807Mechanical Failures
908Bus Signal / Message Failures
1009Component Failures
110ANot compatible
1211circuit short to ground
1312circuit short to battery
1413circuit open
1514circuit short to ground or open
1615circuit short to battery or open
1716circuit voltage below threshold
1817circuit voltage above threshold
1918circuit current below threshold
2019circuit current above threshold
211Acircuit resistance below threshold
221Bcircuit resistance above threshold
231Ccircuit voltage out of range
241Dcircuit current out of range
251Ecircuit resistance out of range
261Fcircuit intermittent
2720test
2821signal amplitude < minimum
2922signal amplitude > maximum
3023signal stuck low
3124signal stuck high
3225signal shape / waveform failure
3326signal rate of change below threshold
3427signal rate of change above threshold
3528signal bias level out of range / zero adjustment failure
3629signal signal invalid
372Fsignal erratic
3831no signal
3932signal low time < minimum
4033signal low time > maximum
4134signal high time < minimum
4235signal high time > maximum
4336signal frequency too low
4437signal frequency too high
4538signal frequency incorrect
4639incorrect has too few pulses
473Aincorrect has too many pulses
4841general checksum failure
4942general memory failure
5043special memory failure
5144data memory failure
5245program memory failure
5346calibration / parameter memory failure
5447watchdog / safety µC failure
5548supervision software failure
5649internal electronic failure
574Aincorrect component installed
584Bover temperature
5951not programmed
6052not activated
6153deactivated
6254missing calibration
6355not configured
6461signal calculation failure
6562signal compare failure
6663circuit / component protection time-out
6764signal plausibility failure
6865signal has too few transitions / events
6966signal has too many transitions / events
7067signal incorrect after event
7168event information
7271actuator stuck
7372actuator stuck open
7473actuator stuck closed
7574actuator slipping
7675emergency position not reachable
7776wrong mounting position
7877commanded position not reachable
7978alignment or adjustment incorrect
8079mechanical linkage failure
817Afluid leak or seal failure
827Blow fluid level
8381invalid serial data received
8482alive / sequence counter incorrect / not updated
8583value of signal protection calculation incorrect
8684signal below allowable range
8785signal above allowable range
8886signal invalid
8987missing message
9088bus off
918Ferratic
9291parametric
9392performance or incorrect operation
9493no operation
9594unexpected operation
9695incorrect assembly
9796component internal failure
9897Component or system operation obstructed or blocked
9998component or system over temperature
100F1Safety Case 1
101F2Safety Case 2
102F3Multiple Failure
103F4Temperature too Low
104F5Negative Loop Error
105F6Positive Loop Error
106F7Initialisation not valid
107F8Overspeed
108F9Limp Home
109FASpecific Supplier
110FB-
111FC--
112FDDrift low
113FEDrift high