Frequently Asked Questions

General Questions

Why I do not get a reply from the remote device when I perform get operation immediately after set operation has been performed?

  • Any Client Model operation needs to wait for the completion event of an ongoing operation. Once the completion event is received the next command can be executed. If a command is executed before the completion event is received, a timeout error will occur.

When I use the API esp_ble_mesh_client_model_send_msg, why does it crash with the log messages Invalid client value when sent client msg or Invalid client value when sent client msg?

  • You should initialize a structure of the type esp_ble_mesh_client_t and set its value as the user data of client model.