tcp_transport/ws_client: websockets now correctly handle messages longer than buffer
Closes IDF-1084 and IDF-1083
See merge request espressif/esp-idf!6740
For SoftAP provisioning, if we start Wi-Fi connection as soon as the
apply config request is received, it has been observed that the clients
(Phone apps mostly) do not get the response for this as we switch the
Wi-Fi channel, causing a momentary disconnection.
Delaying the connection calls helps mitigate the issue.
Signed-off-by: Piyush Shah <piyush@espressif.com>
transport_ws can now be read multiple times in a row to read frames larger than the buffer.
Added reporting of total payload length and offset to the user in websocket_client.
Added local example test for long messages.
Closes IDF-1083
DISABLED_FOR_TARGETS macros are used
Partly revert "ci: disable unavailable tests for esp32s2beta"
This partly reverts commit 76a3a5fb48.
Partly revert "ci: disable UTs for esp32s2beta without runners"
This partly reverts commit eb158e9a22.
Partly revert "fix unit test and examples for s2beta"
This partly reverts commit 9baa7826be.
Partly revert "efuse: Add support for esp32s2beta"
This partly reverts commit db84ba868c.
The upper transport layer is using big endian ordering. The
PreviousAddress field of a Friend Request message should therefore
be converted to native endianess using sys_cpu_to_be16().
If the duration to publish is roughly the same as the period, we might
end up with elapsed == period, which returns 0 and cancel the periodic
publication. Instead 1 should be returned, just like when the elapsed
time is greater than the period.
Previously the FastPeriodDivisor value was introduced to the model
publication struct. Based on the way it was grouped it seems the
intention was to fit it within the same octet as other bit fields,
but it actually makes the octet overflow by one bit. This ends up
creating another u8_t variable which in turn adds 24 bits of padding
after it.
To keep the size of the struct as compact as possible, group the flag
together with the key index, since that only requires 12 bits. Some
care is needed here, since the mesh stack does have special internal
key index values that require more than 12 bits such as
BLE_MESH_KEY_UNUSED and BLE_MESH_KEY_DEV. In this case restricting
ourselves to 12 bits is fine since the value in the model publication
struct follows 1:1 the value received in the Config Model Publication
Set message, and there the parameter is defined to be exactly 12 bits.
For Low Power node and Proxy Server, the two features
depend on BLE_MESH_NODE in Kconfig.in, here in the
stack there is no need to judge if CONFIG_BLE_MESH_NODE
is enabled.