Works for 3.3V eMMC in 4 line mode.
Not implemented:
- DDR mode for SD cards (UHS-I) also need voltage to be switched to 1.8V.
- 8-line DDR mode for eMMC to be implemented later.
This introduces the following changes in the example test scripts :
* Dependency on python requests library removed in favor of httplib
* Bug fixed in the logic responsible for receiving and processing http chunked responses
* Default timeouts increased Note : Due to connectivity issues (between runner host and DUT) in the runner environment, some of the advanced_tests are being ignored. These tests are intended for verifying the expected limits of the http_server capabilities, and implement sending and receiving of large HTTP packets and malformed requests, running multiple parallel sessions, etc. It is advised that all these tests be run locally, when making changes or adding new features to this component.
It is possible to utilize some of the routines related to otadata
partition validation, after firmware image is downloaded to RAM. Hence
these routines should be part of app cpu cache, so that they do not
get overwritten by firmware.
Signed-off-by: Mahavir Jain <mahavir@espressif.com>
Allows OTA updates to be secured via signature checks, without requiring the overhead or complexity
of a full secure boot implementation.
Uses same signing mechanisms (build system and/or espsecure.py as Secure Boot).
Requires:
* [ ] More testing
* [ ] Documentation
Fixes mismatches where default Python interpreter may not match the most recently
installed sphinx-build wrapper script (if sphinx 2 & 3 both installed, pip will
clobber any previous copy of /bin/sphinx-build when it installs the new one.)
res was declared as “bool” so expression
((count == 0) ? A2D_SET_ONE_BIT : A2D_SET_MULTL_BIT)
always evaluated to “true”, and was implicitly converted to
A2D_SET_ONE_BIT.
Avoids growing the result of hardware bignum operations
(particularly for multiplication)
Fixes bugs where some Elliptic Curve operations fail or corrupt memory,
as they assume length of the number is never greater than the number of
non-zero limbs.
Includes some general refactoring to standardize terminology.
Closes https://github.com/espressif/esp-idf/issues/1556
Fixes TW12984
Adds test cases for both these issues.
1. after memory release MR merged, due to the get acl number condition is not completed, it will cause get acl number value incorrect
2. It may cause set Security Mode (BR/EDR) enable failed