Update Detailed Control Menu

Ray Jones 2019-01-23 09:13:19 +00:00
parent 6411ec4806
commit b549fd7b4d

@ -35,12 +35,14 @@ Once the body temperature rises over about 65 degrees or so, the glow plug is sh
The heater runs in this state for quite a few minutes getting the internals nice and hot. The heater runs in this state for quite a few minutes getting the internals nice and hot.
![ScreenDetailedIgnitedGlowOff](uploads/e3eef473f0547203b173befd5a4b5ca7/ScreenDetailedIgnitedGlowOff.jpg) ![ScreenDetailedIgnitedGlowOff](uploads/e3eef473f0547203b173befd5a4b5ca7/ScreenDetailedIgnitedGlowOff.jpg)
After running at full speed for a while, the heater transitions to the running state, and now obeys the desired setting being ewither a thermostat setting, or a fixed heat demand. After running at full speed for a while, the heater transitions to the running state, and now obeys the desired setting being either a thermostat setting, or a fixed heat demand.
This happens about 5 minutes after the initial start was demanded: This happens about 5 minutes after the initial start was demanded:
![ScreenDetailedRunning](uploads/a2c11dbf0a7e39b00feabb583b80102c/ScreenDetailedRunning.jpg) ![ScreenDetailedRunning](uploads/a2c11dbf0a7e39b00feabb583b80102c/ScreenDetailedRunning.jpg)
To toggle from Thermostat or Fixed demand modes, hold the down key. To toggle from Thermostat or Fixed demand modes, hold the down key.
The changed operating mode is reflected in the units reported below the target icon. DegC for thermostat, Hz for fixed demand: The changed operating mode is reflected in the units reported below the target icon.
DegC for thermostat, Hz for fixed demand.
The set temperature indicator also disappears from the left hand side thermometer when in fixed demand mode:
![ScreenDetailedFixedHz](uploads/14f7975a7e8751fd35313fc5343e5004/ScreenDetailedFixedHz.jpg) ![ScreenDetailedFixedHz](uploads/14f7975a7e8751fd35313fc5343e5004/ScreenDetailedFixedHz.jpg)
## Stopping the heater ## Stopping the heater
@ -52,7 +54,8 @@ The pump speed is quickly lowered and eventually shut off, the glow plug is gent
![ScreenDetailedShutdownLowPump](uploads/6c7390ad2fdb47585f775406c0a166ba/ScreenDetailedShutdownLowPump.jpg) ![ScreenDetailedShutdownLowPump](uploads/6c7390ad2fdb47585f775406c0a166ba/ScreenDetailedShutdownLowPump.jpg)
![ScreenDetailedShutdownPumpOff](uploads/a811eb45c5fa2dee814cdd65130bff4e/ScreenDetailedShutdownPumpOff.jpg) ![ScreenDetailedShutdownPumpOff](uploads/a811eb45c5fa2dee814cdd65130bff4e/ScreenDetailedShutdownPumpOff.jpg)
About a minute later the glow plug is un-powered and the heater then transitions to cooldown mode: About a minute later the glow plug is un-powered and the heater then transitions to cooldown mode.
Only the fan is now running:
![ScreenDetailedCooling](uploads/e191cc96a957d7d33b26b4983609bab4/ScreenDetailedCooling.jpg) ![ScreenDetailedCooling](uploads/e191cc96a957d7d33b26b4983609bab4/ScreenDetailedCooling.jpg)
It stays in cooldown mode until the heat exchanger is observed to have dropped below 55 degC, at which point it then returns to the initial idle state. It stays in cooldown mode until the heat exchanger is observed to have dropped below 55 degC, at which point it then returns to the initial idle state.