# coding: utf8
|
||
|
# This file is part of Scapy
|
||
|
# Scapy is free software: you can redistribute it and/or modify
|
||
|
# it under the terms of the GNU General Public License as published by
|
||
|
# the Free Software Foundation, either version 2 of the License, or
|
||
|
# any later version.
|
||
|
#
|
||
|
# Scapy is distributed in the hope that it will be useful,
|
||
|
# but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||
|
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||
|
# GNU General Public License for more details.
|
||
|
#
|
||
|
# You should have received a copy of the GNU General Public License
|
||
|
# along with Scapy. If not, see <http://www.gnu.org/licenses/>.
|
||
|
|
||
|
# Copyright (C) 2016 Gauthier Sebaux
|
||
|
|
||
|
# scapy.contrib.description = ProfinetIO RTC (+Profisafe) layer
|
||
|
# scapy.contrib.status = loads
|
||
|
import copy
|
||
|
from scapy.compat import raw
|
||
|
from scapy.error import Scapy_Exception
|
||
|
from scapy.config import conf
|
||
|
from scapy.packet import Packet, bind_layers
|
||
|
from scapy.layers.l2 import Ether
|
||
|
from scapy.layers.inet import UDP
|
||
|
from scapy.fields import (
|
||
|
XShortEnumField, BitEnumField, XBitField,
|
||
|
BitField, StrField, PacketListField,
|
||
|
StrFixedLenField, ShortField,
|
||
|
FlagsField, ByteField, XIntField, X3BytesField
|
||
|
)
|
||
|
from scapy.modules import six
|
||
|
|
||
|
PNIO_FRAME_IDS = {
|
||
|
0x0020: "PTCP-RTSyncPDU-followup",
|
||
|
0x0080: "PTCP-RTSyncPDU",
|
||
|
0xFC01: "Alarm High",
|
||
|
0xFE01: "Alarm Low",
|
||
|
0xFEFC: "DCP-Hello-Req",
|
||
|
0xFEFD: "DCP-Get-Set",
|
||
|
0xFEFE: "DCP-Identify-ReqPDU",
|
||
|
0xFEFF: "DCP-Identify-ResPDU",
|
||
|
0xFF00: "PTCP-AnnouncePDU",
|
||
|
0xFF20: "PTCP-FollowUpPDU",
|
||
|
0xFF40: "PTCP-DelayReqPDU",
|
||
|
0xFF41: "PTCP-DelayResPDU-followup",
|
||
|
0xFF42: "PTCP-DelayFuResPDU",
|
||
|
0xFF43: "PTCP-DelayResPDU",
|
||
|
}
|
||
|
|
||
|
|
||
|
def i2s_frameid(x):
|
||
|
""" Get representation name of a pnio frame ID
|
||
|
|
||
|
:param x: a key of the PNIO_FRAME_IDS dictionary
|
||
|
:returns: str
|
||
|
"""
|
||
|
try:
|
||
|
return PNIO_FRAME_IDS[x]
|
||
|
except KeyError:
|
||
|
pass
|
||
|
if 0x0100 <= x < 0x1000:
|
||
|
return "RT_CLASS_3 (%4x)" % x
|
||
|
if 0x8000 <= x < 0xC000:
|
||
|
return "RT_CLASS_1 (%4x)" % x
|
||
|
if 0xC000 <= x < 0xFC00:
|
||
|
return "RT_CLASS_UDP (%4x)" % x
|
||
|
if 0xFF80 <= x < 0xFF90:
|
||
|
return "FragmentationFrameID (%4x)" % x
|
||
|
return x
|
||
|
|
||
|
|
||
|
def s2i_frameid(x):
|
||
|
""" Get pnio frame ID from a representation name
|
||
|
|
||
|
Performs a reverse look-up in PNIO_FRAME_IDS dictionary
|
||
|
|
||
|
:param x: a value of PNIO_FRAME_IDS dict
|
||
|
:returns: integer
|
||
|
"""
|
||
|
try:
|
||
|
return {
|
||
|
"RT_CLASS_3": 0x0100,
|
||
|
"RT_CLASS_1": 0x8000,
|
||
|
"RT_CLASS_UDP": 0xC000,
|
||
|
"FragmentationFrameID": 0xFF80,
|
||
|
}[x]
|
||
|
except KeyError:
|
||
|
pass
|
||
|
try:
|
||
|
return next(key for key, value in six.iteritems(PNIO_FRAME_IDS)
|
||
|
if value == x)
|
||
|
except StopIteration:
|
||
|
pass
|
||
|
return x
|
||
|
|
||
|
|
||
|
#################
|
||
|
# PROFINET IO #
|
||
|
#################
|
||
|
|
||
|
class ProfinetIO(Packet):
|
||
|
""" Basic PROFINET IO dispatcher """
|
||
|
fields_desc = [
|
||
|
XShortEnumField("frameID", 0, (i2s_frameid, s2i_frameid))
|
||
|
]
|
||
|
|
||
|
def guess_payload_class(self, payload):
|
||
|
# For frameID in the RT_CLASS_* range, use the RTC packet as payload
|
||
|
if self.frameID in [0xfefe, 0xfeff, 0xfefd]:
|
||
|
from scapy.contrib.pnio_dcp import ProfinetDCP
|
||
|
return ProfinetDCP
|
||
|
elif (
|
||
|
(0x0100 <= self.frameID < 0x1000) or
|
||
|
(0x8000 <= self.frameID < 0xFC00)
|
||
|
|
||
|
|
||
|
):
|
||
|
return PNIORealTimeCyclicPDU
|
||
|
return super(ProfinetIO, self).guess_payload_class(payload)
|
||
|
|
||
|
|
||
|
bind_layers(Ether, ProfinetIO, type=0x8892)
|
||
|
bind_layers(UDP, ProfinetIO, dport=0x8892)
|
||
|
|
||
|
|
||
|
#####################################
|
||
|
# PROFINET Real-Time Data Packets #
|
||
|
#####################################
|
||
|
|
||
|
conf.contribs["PNIO_RTC"] = {}
|
||
|
|
||
|
|
||
|
class PNIORealTime_IOxS(Packet):
|
||
|
""" IOCS and IOPS packets for PROFINET Real-Time payload """
|
||
|
name = "PNIO RTC IOxS"
|
||
|
fields_desc = [
|
||
|
# IOxS.DataState -- IEC-61158 - 6 - 10 / FDIS ED 3, Table 181
|
||
|
BitEnumField("dataState", 1, 1, ["bad", "good"]),
|
||
|
# IOxS.Instance -- IEC-61158 - 6 - 10 / FDIS ED 3, Table 180
|
||
|
BitEnumField("instance", 0, 2,
|
||
|
["subslot", "slot", "device", "controller"]),
|
||
|
# IOxS.reserved -- IEC-61158 - 6 - 10 / FDIS ED 3, line 2649
|
||
|
XBitField("reserved", 0, 4),
|
||
|
# IOxS.Extension -- IEC-61158-6-10/FDIS ED 3, Table 179
|
||
|
BitField("extension", 0, 1),
|
||
|
]
|
||
|
|
||
|
@classmethod
|
||
|
def is_extension_set(cls, _pkt, _lst, p, _remain):
|
||
|
ret = cls if isinstance(p, type(None)) or p.extension != 0 else None
|
||
|
return ret
|
||
|
|
||
|
@classmethod
|
||
|
def get_len(cls):
|
||
|
return sum(type(fld).i2len(None, 0) for fld in cls.fields_desc)
|
||
|
|
||
|
def guess_payload_class(self, p):
|
||
|
return conf.padding_layer
|
||
|
|
||
|
|
||
|
class PNIORealTimeCyclicDefaultRawData(Packet):
|
||
|
name = "PROFINET IO Real Time Cyclic Default Raw Data"
|
||
|
fields_desc = [
|
||
|
# 4 is the sum of the size of the CycleCounter + DataStatus
|
||
|
# + TransferStatus trailing from PNIORealTimeCyclicPDU
|
||
|
StrField("data", '', remain=4)
|
||
|
]
|
||
|
|
||
|
def guess_payload_class(self, payload):
|
||
|
return conf.padding_layer
|
||
|
|
||
|
|
||
|
class PNIORealTimeCyclicPDU(Packet):
|
||
|
""" PROFINET cyclic real-time """
|
||
|
__slots__ = ["_len", "_layout"]
|
||
|
name = "PROFINET Real-Time"
|
||
|
|
||
|
fields_desc = [
|
||
|
# C_SDU ^ CSF_SDU -- IEC-61158-6-10/FDIS ED 3, Table 163
|
||
|
PacketListField(
|
||
|
"data", [],
|
||
|
next_cls_cb=lambda pkt, lst, p, remain: pkt.next_cls_cb(
|
||
|
lst, p, remain)
|
||
|
),
|
||
|
# RTCPadding -- IEC - 61158 - 6 - 10 / FDIS ED 3, Table 163
|
||
|
StrFixedLenField("padding", '',
|
||
|
length_from=lambda p: p.get_padding_length()),
|
||
|
# APDU_Status -- IEC-61158-6-10/FDIS ED 3, Table 164
|
||
|
ShortField("cycleCounter", 0),
|
||
|
FlagsField("dataStatus", 0x35, 8, [
|
||
|
"primary",
|
||
|
"redundancy",
|
||
|
"validData",
|
||
|
"reserved_1",
|
||
|
"run",
|
||
|
"no_problem",
|
||
|
"reserved_2",
|
||
|
"ignore",
|
||
|
]),
|
||
|
ByteField("transferStatus", 0)
|
||
|
]
|
||
|
|
||
|
def pre_dissect(self, s):
|
||
|
# Constraint from IEC-61158-6-10/FDIS ED 3, line 690
|
||
|
self._len = min(1440, len(s))
|
||
|
return s
|
||
|
|
||
|
def get_padding_length(self):
|
||
|
if hasattr(self, "_len"):
|
||
|
pad_len = (
|
||
|
self._len -
|
||
|
sum(len(raw(pkt)) for pkt in self.getfieldval("data")) -
|
||
|
2 - # Cycle Counter size (ShortField)
|
||
|
1 - # DataStatus size (FlagsField over 8 bits)
|
||
|
1 # TransferStatus (ByteField)
|
||
|
)
|
||
|
else:
|
||
|
pad_len = len(self.getfieldval("padding"))
|
||
|
|
||
|
# Constraints from IEC-61158-6-10/FDIS ED 3, Table 163
|
||
|
assert(0 <= pad_len <= 40)
|
||
|
q = self
|
||
|
while not isinstance(q, UDP) and hasattr(q, "underlayer"):
|
||
|
q = q.underlayer
|
||
|
if isinstance(q, UDP):
|
||
|
assert(0 <= pad_len <= 12)
|
||
|
return pad_len
|
||
|
|
||
|
def next_cls_cb(self, _lst, _p, _remain):
|
||
|
if hasattr(self, "_layout") and isinstance(self._layout, list):
|
||
|
try:
|
||
|
return self._layout.pop(0)
|
||
|
except IndexError:
|
||
|
self._layout = None
|
||
|
return None
|
||
|
|
||
|
ether_layer = None
|
||
|
q = self
|
||
|
while not isinstance(q, Ether) and hasattr(q, "underlayer"):
|
||
|
q = q.underlayer
|
||
|
if isinstance(q, Ether):
|
||
|
ether_layer = q
|
||
|
|
||
|
pnio_layer = None
|
||
|
q = self
|
||
|
while not isinstance(q, ProfinetIO) and hasattr(q, "underlayer"):
|
||
|
q = q.underlayer
|
||
|
if isinstance(q, ProfinetIO):
|
||
|
pnio_layer = q
|
||
|
|
||
|
self._layout = [PNIORealTimeCyclicDefaultRawData]
|
||
|
if not (ether_layer is None and pnio_layer is None):
|
||
|
# Get from config the layout for these hosts and frameid
|
||
|
layout = type(self).get_layout_from_config(
|
||
|
ether_layer.src,
|
||
|
ether_layer.dst,
|
||
|
pnio_layer.frameID)
|
||
|
if not isinstance(layout, type(None)):
|
||
|
self._layout = layout
|
||
|
|
||
|
return self._layout.pop(0)
|
||
|
|
||
|
@staticmethod
|
||
|
def get_layout_from_config(ether_src, ether_dst, frame_id):
|
||
|
try:
|
||
|
return copy.deepcopy(
|
||
|
conf.contribs["PNIO_RTC"][(ether_src, ether_dst, frame_id)]
|
||
|
)
|
||
|
except KeyError:
|
||
|
return None
|
||
|
|
||
|
@staticmethod
|
||
|
def build_fixed_len_raw_type(length):
|
||
|
return type(
|
||
|
"FixedLenRawPacketLen{}".format(length),
|
||
|
(conf.raw_layer,),
|
||
|
{
|
||
|
"name": "FixedLenRawPacketLen{}".format(length),
|
||
|
"fields_desc": [StrFixedLenField("data", '', length=length)],
|
||
|
"get_data_length": lambda _: length,
|
||
|
"guess_payload_class": lambda self, p: conf.padding_layer,
|
||
|
}
|
||
|
)
|
||
|
|
||
|
|
||
|
# From IEC 61784-3-3 Ed. 3 PROFIsafe v.2.6, Figure 20
|
||
|
profisafe_control_flags = [
|
||
|
"iPar_EN", "OA_Req", "R_cons_nr", "Use_TO2",
|
||
|
"activate_FV", "Toggle_h", "ChF_Ack", "Loopcheck"
|
||
|
]
|
||
|
# From IEC 61784-3-3 Ed. 3 PROFIsafe v.2.6, Figure 19
|
||
|
profisafe_status_flags = [
|
||
|
"iPar_OK", "Device_Fault/ChF_Ack_Req", "CE_CRC",
|
||
|
"WD_timeout", "FV_activated", "Toggle_d", "cons_nr_R", "reserved"
|
||
|
]
|
||
|
|
||
|
|
||
|
class PROFIsafeCRCSeed(Packet):
|
||
|
__slots__ = ["_len"] + Packet.__slots__
|
||
|
|
||
|
def guess_payload_class(self, p):
|
||
|
return conf.padding_layer
|
||
|
|
||
|
def get_data_length(self):
|
||
|
""" Must be overridden in a subclass to return the correct value """
|
||
|
raise Scapy_Exception(
|
||
|
"This method must be overridden in a specific subclass"
|
||
|
)
|
||
|
|
||
|
def get_mandatory_fields_len(self):
|
||
|
# 5 is the len of the control/status byte + the CRC length
|
||
|
return 5
|
||
|
|
||
|
@staticmethod
|
||
|
def get_max_data_length():
|
||
|
# Constraints from IEC-61784-3-3 ED 3, Figure 18
|
||
|
return 13
|
||
|
|
||
|
|
||
|
class PROFIsafeControlCRCSeed(PROFIsafeCRCSeed):
|
||
|
name = "PROFISafe Control Message with F_CRC_Seed=1"
|
||
|
fields_desc = [
|
||
|
StrFixedLenField("data", '',
|
||
|
length_from=lambda p: p.get_data_length()),
|
||
|
FlagsField("control", 0, 8, profisafe_control_flags),
|
||
|
XIntField("crc", 0)
|
||
|
]
|
||
|
|
||
|
|
||
|
class PROFIsafeStatusCRCSeed(PROFIsafeCRCSeed):
|
||
|
name = "PROFISafe Status Message with F_CRC_Seed=1"
|
||
|
fields_desc = [
|
||
|
StrFixedLenField("data", '',
|
||
|
length_from=lambda p: p.get_data_length()),
|
||
|
FlagsField("status", 0, 8, profisafe_status_flags),
|
||
|
XIntField("crc", 0)
|
||
|
]
|
||
|
|
||
|
|
||
|
class PROFIsafe(Packet):
|
||
|
__slots__ = ["_len"] + Packet.__slots__
|
||
|
|
||
|
def guess_payload_class(self, p):
|
||
|
return conf.padding_layer
|
||
|
|
||
|
def get_data_length(self):
|
||
|
""" Must be overridden in a subclass to return the correct value """
|
||
|
raise Scapy_Exception(
|
||
|
"This method must be overridden in a specific subclass"
|
||
|
)
|
||
|
|
||
|
def get_mandatory_fields_len(self):
|
||
|
# 4 is the len of the control/status byte + the CRC length
|
||
|
return 4
|
||
|
|
||
|
@staticmethod
|
||
|
def get_max_data_length():
|
||
|
# Constraints from IEC-61784-3-3 ED 3, Figure 18
|
||
|
return 12
|
||
|
|
||
|
@staticmethod
|
||
|
def build_PROFIsafe_class(cls, data_length):
|
||
|
assert(cls.get_max_data_length() >= data_length)
|
||
|
return type(
|
||
|
"{}Len{}".format(cls.__name__, data_length),
|
||
|
(cls,),
|
||
|
{
|
||
|
"get_data_length": lambda _: data_length,
|
||
|
}
|
||
|
)
|
||
|
|
||
|
|
||
|
class PROFIsafeControl(PROFIsafe):
|
||
|
name = "PROFISafe Control Message with F_CRC_Seed=0"
|
||
|
fields_desc = [
|
||
|
StrFixedLenField("data", '',
|
||
|
length_from=lambda p: p.get_data_length()),
|
||
|
FlagsField("control", 0, 8, profisafe_control_flags),
|
||
|
X3BytesField("crc", 0)
|
||
|
]
|
||
|
|
||
|
|
||
|
class PROFIsafeStatus(PROFIsafe):
|
||
|
name = "PROFISafe Status Message with F_CRC_Seed=0"
|
||
|
fields_desc = [
|
||
|
StrFixedLenField("data", '',
|
||
|
length_from=lambda p: p.get_data_length()),
|
||
|
FlagsField("status", 0, 8, profisafe_status_flags),
|
||
|
X3BytesField("crc", 0)
|
||
|
]
|