163 lines
No EOL
7.6 KiB
Python
163 lines
No EOL
7.6 KiB
Python
#!/usr/bin/env python
|
|
|
|
try:
|
|
import gobject # Python 2.x
|
|
except:
|
|
from gi.repository import GLib as gobject # Python 3.x
|
|
import platform
|
|
import logging
|
|
import sys
|
|
import os
|
|
import requests # for http GET
|
|
try:
|
|
import thread # for daemon = True / Python 2.x
|
|
except:
|
|
import _thread as thread # for daemon = True / Python 3.x
|
|
|
|
# our own packages
|
|
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '../ext/velib_python'))
|
|
from vedbus import VeDbusService
|
|
|
|
path_UpdateIndex = '/UpdateIndex'
|
|
|
|
|
|
class NodeRedMeterEinspeisung:
|
|
def __init__(self, servicename, deviceinstance, paths, productname='Einspeisung', connection='NodeRED local'):
|
|
self._dbusservice = VeDbusService(servicename)
|
|
self._paths = paths
|
|
|
|
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
|
|
|
|
# Create the management objects, as specified in the ccgx dbus-api document
|
|
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
|
|
self._dbusservice.add_path('/Mgmt/Connection', connection)
|
|
|
|
# Create the mandatory objects
|
|
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
|
|
self._dbusservice.add_path('/ProductId', 0xB017) # like a EM24
|
|
self._dbusservice.add_path('/DeviceType', 72) # like a EM24
|
|
self._dbusservice.add_path('/ProductName', productname)
|
|
self._dbusservice.add_path('/FirmwareVersion', 1.0)
|
|
self._dbusservice.add_path('/HardwareVersion', 0)
|
|
self._dbusservice.add_path('/Connected', 1)
|
|
|
|
for path, settings in self._paths.items():
|
|
self._dbusservice.add_path(
|
|
path, settings['initial'], writeable=True, onchangecallback=self._handlechangedvalue)
|
|
|
|
gobject.timeout_add(1000, self._update) # pause 1000ms before the next request
|
|
|
|
def _update(self):
|
|
try:
|
|
self._dbusservice['/ErrorCode'] = 0
|
|
nodered_url = "http://localhost:1880/meters"
|
|
nodered_r = requests.get(url=nodered_url) # request data from the Fronius PV inverter
|
|
nodered_data = nodered_r.json() # convert JSON data
|
|
self._dbusservice['/Ac/Power'] = nodered_data['einspeisung']['total_power']
|
|
self._dbusservice['/Ac/Current'] = nodered_data['einspeisung']['total_current']
|
|
self._dbusservice['/Ac/Energy/Forward'] = nodered_data['einspeisung']['total_import']
|
|
self._dbusservice['/Ac/Energy/Reverse'] = nodered_data['einspeisung']['total_export']
|
|
self._dbusservice['/Ac/L1/Voltage'] = nodered_data['einspeisung']['l1_voltage']
|
|
self._dbusservice['/Ac/L2/Voltage'] = nodered_data['einspeisung']['l2_voltage']
|
|
self._dbusservice['/Ac/L3/Voltage'] = nodered_data['einspeisung']['l3_voltage']
|
|
self._dbusservice['/Ac/L1/Current'] = nodered_data['einspeisung']['l1_current']
|
|
self._dbusservice['/Ac/L2/Current'] = nodered_data['einspeisung']['l2_current']
|
|
self._dbusservice['/Ac/L3/Current'] = nodered_data['einspeisung']['l3_current']
|
|
self._dbusservice['/Ac/L1/Power'] = nodered_data['einspeisung']['l1_power']
|
|
self._dbusservice['/Ac/L2/Power'] = nodered_data['einspeisung']['l2_power']
|
|
self._dbusservice['/Ac/L3/Power'] = nodered_data['einspeisung']['l3_power']
|
|
self._dbusservice['/Ac/L1/Energy/Forward'] = nodered_data['einspeisung']['l1_import']
|
|
self._dbusservice['/Ac/L2/Energy/Forward'] = nodered_data['einspeisung']['l2_import']
|
|
self._dbusservice['/Ac/L3/Energy/Forward'] = nodered_data['einspeisung']['l3_import']
|
|
self._dbusservice['/Ac/L1/Energy/Reverse'] = nodered_data['einspeisung']['l1_export']
|
|
self._dbusservice['/Ac/L2/Energy/Reverse'] = nodered_data['einspeisung']['l2_export']
|
|
self._dbusservice['/Ac/L3/Energy/Reverse'] = nodered_data['einspeisung']['l3_export']
|
|
|
|
logging.debug("House Consumption (/Ac/Power): %s" % (self._dbusservice['/Ac/Power']))
|
|
logging.debug("House Forward (/Ac/Energy/Forward): %s" % (self._dbusservice['/Ac/Energy/Forward']))
|
|
logging.debug("House Reverse (/Ac/Energy/Revers): %s" % (self._dbusservice['/Ac/Energy/Reverse']))
|
|
logging.debug("---");
|
|
|
|
index = self._dbusservice[path_UpdateIndex] + 1 # increment index
|
|
if index > 255: # maximum value of the index
|
|
index = 0 # overflow from 255 to 0
|
|
self._dbusservice[path_UpdateIndex] = index
|
|
|
|
except Exception as e:
|
|
logging.critical("WARNING: Could not read from Node Red, check if Node Red service is running")
|
|
logging.critical('Error at %s', '_update', exc_info=e)
|
|
self._dbusservice['/ErrorCode'] = 1
|
|
self._dbusservice['/Ac/Power'] = 0
|
|
self._dbusservice['/Ac/Current'] = 0
|
|
self._dbusservice['/Ac/L1/Voltage'] = 0
|
|
self._dbusservice['/Ac/L2/Voltage'] = 0
|
|
self._dbusservice['/Ac/L3/Voltage'] = 0
|
|
self._dbusservice['/Ac/L1/Current'] = 0
|
|
self._dbusservice['/Ac/L2/Current'] = 0
|
|
self._dbusservice['/Ac/L3/Current'] = 0
|
|
self._dbusservice['/Ac/L1/Power'] = 0
|
|
self._dbusservice['/Ac/L2/Power'] = 0
|
|
self._dbusservice['/Ac/L3/Power'] = 0
|
|
|
|
return True
|
|
|
|
def _handlechangedvalue(self, path, value):
|
|
logging.debug("someone else updated %s to %s" % (path, value))
|
|
return True # accept the change
|
|
|
|
def main():
|
|
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
|
|
datefmt='%Y-%m-%d %H:%M:%S',
|
|
level=logging.DEBUG,
|
|
handlers=[
|
|
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
|
|
logging.StreamHandler()
|
|
])
|
|
thread.daemon = True # allow the program to quit
|
|
try:
|
|
from dbus.mainloop.glib import DBusGMainLoop
|
|
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
|
|
DBusGMainLoop(set_as_default=True)
|
|
_kwh = lambda p, v: (str(round(v, 2)) + ' KWh')
|
|
_A = lambda p, v: (str(round(v, 1)) + ' A')
|
|
_W = lambda p, v: (str(round(v, 1)) + ' W')
|
|
_V = lambda p, v: (str(round(v, 1)) + ' V')
|
|
|
|
|
|
pvac_output = NodeRedMeterEinspeisung(
|
|
servicename='com.victronenergy.grid',
|
|
deviceinstance=40,
|
|
paths={
|
|
'/ErrorCode': {'initial': 0},
|
|
'/Ac/Power': {'initial': 0, 'textformat': _W},
|
|
'/Ac/Current': {'initial': 0, 'textformat': _A},
|
|
'/Ac/L1/Voltage': {'initial': 0, 'textformat': _V},
|
|
'/Ac/L2/Voltage': {'initial': 0, 'textformat': _V},
|
|
'/Ac/L3/Voltage': {'initial': 0, 'textformat': _V},
|
|
'/Ac/L1/Current': {'initial': 0, 'textformat': _A},
|
|
'/Ac/L2/Current': {'initial': 0, 'textformat': _A},
|
|
'/Ac/L3/Current': {'initial': 0, 'textformat': _A},
|
|
'/Ac/L1/Power': {'initial': 0, 'textformat': _W},
|
|
'/Ac/L2/Power': {'initial': 0, 'textformat': _W},
|
|
'/Ac/L3/Power': {'initial': 0, 'textformat': _W},
|
|
'/Ac/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/Energy/Reverse': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/L1/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/L2/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/L3/Energy/Forward': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/L1/Energy/Reverse': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/L2/Energy/Reverse': {'initial': 0, 'textformat': _kwh},
|
|
'/Ac/L3/Energy/Reverse': {'initial': 0, 'textformat': _kwh},
|
|
|
|
path_UpdateIndex: {'initial': 0},
|
|
})
|
|
|
|
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
|
|
mainloop = gobject.MainLoop()
|
|
mainloop.run()
|
|
|
|
except Exception as e:
|
|
logging.critical('Error at %s', 'main', exc_info=e)
|
|
|
|
if __name__ == "__main__":
|
|
main() |