369 lines
19 KiB
Python
369 lines
19 KiB
Python
#!/usr/bin/env python3
|
|
|
|
"""
|
|
A class to put a battery service on the dbus, according to victron standards, with constantly updating
|
|
paths.
|
|
|
|
"""
|
|
from gi.repository import GLib
|
|
import platform
|
|
import argparse
|
|
import logging
|
|
import sys
|
|
import os
|
|
import dbus
|
|
import itertools
|
|
import math
|
|
|
|
from time import time
|
|
from datetime import datetime
|
|
import struct
|
|
from argparse import ArgumentParser
|
|
|
|
from batrium import *
|
|
|
|
|
|
# Victron energy libraries
|
|
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '/opt/victronenergy/dbus-systemcalc-py/ext/velib_python'))
|
|
from vedbus import VeDbusService
|
|
from ve_utils import exit_on_error
|
|
from settingsdevice import SettingsDevice
|
|
|
|
VERSION = '1.0'
|
|
|
|
def handle_changed_setting(setting, oldvalue, newvalue):
|
|
logging.debug('setting changed, setting: %s, old: %s, new: %s' % (setting, oldvalue, newvalue))
|
|
|
|
|
|
class DbusBatteryService:
|
|
def __init__(self, servicename, deviceinstance, productname='Batrium BMS', connection='can0'):
|
|
self.minUpdateDone = 0
|
|
self.secUpdateDone = 0
|
|
self.dailyResetDone = 0
|
|
self.lastUpdated = 0
|
|
self.cell_balanced = 0
|
|
self.ChargedEnergy = 0
|
|
self.DischargedEnergy = 0
|
|
self.maxChargeVoltage = 0
|
|
self._bat = BatriumBattery(connection=connection)
|
|
self.notifier = can.Notifier(self._bat._ci, [self._bat])
|
|
|
|
try:
|
|
self._dbusservice = VeDbusService(servicename+'.socketcan_'+connection+'_di'+str(deviceinstance))
|
|
except:
|
|
exit
|
|
|
|
# Create the management objects, as specified in the Venus OS dbus-api document https://github.com/victronenergy/venus/wiki/dbus-api
|
|
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
|
|
self._dbusservice.add_path('/Mgmt/ProcessVersion', VERSION + ' running on Python ' + platform.python_version())
|
|
self._dbusservice.add_path('/Mgmt/Connection', connection)
|
|
|
|
# Create the mandatory objects
|
|
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
|
|
self._dbusservice.add_path('/ProductId', 0xB038)
|
|
self._dbusservice.add_path('/ProductName', productname)
|
|
self._dbusservice.add_path('/FirmwareVersion', 'unknown')
|
|
self._dbusservice.add_path('/HardwareVersion', 'unknown')
|
|
self._dbusservice.add_path('/Connected', 0)
|
|
# Create battery specific objects
|
|
self._dbusservice.add_path('/Status', 0, writeable=False)
|
|
self._dbusservice.add_path('/Dc/0/Temperature', None, writeable=True)
|
|
self._dbusservice.add_path('/Info/BatteryLowVoltage', None, writeable=True)
|
|
self._dbusservice.add_path('/Alarms/CellImbalance', None, writeable=True)
|
|
self._dbusservice.add_path('/Alarms/LowVoltage', None, writeable=True)
|
|
self._dbusservice.add_path('/Alarms/HighVoltage', None, writeable=True)
|
|
self._dbusservice.add_path('/Alarms/HighDischargeCurrent', None, writeable=True)
|
|
self._dbusservice.add_path('/Alarms/HighChargeCurrent', None, writeable=True)
|
|
self._dbusservice.add_path('/Alarms/LowSoc', None, writeable=True)
|
|
self._dbusservice.add_path('/Alarms/LowTemperature', None, writeable=True)
|
|
self._dbusservice.add_path('/Alarms/HighTemperature', None, writeable=True)
|
|
self._dbusservice.add_path('/Balancing', None, writeable=True)
|
|
self._dbusservice.add_path('/System/HasTemperature', 1)
|
|
self._dbusservice.add_path('/System/NrOfBatteries', 1)
|
|
self._dbusservice.add_path('/System/NrOfModulesOnline', None, writeable=True)
|
|
self._dbusservice.add_path('/System/NrOfModulesOffline', 0)
|
|
self._dbusservice.add_path('/System/NrOfModulesBlockingDischarge', 0)
|
|
self._dbusservice.add_path('/System/NrOfModulesBlockingCharge', 0)
|
|
self._dbusservice.add_path('/System/NrOfBatteriesBalancing', None, writeable=True)
|
|
self._dbusservice.add_path('/System/BatteriesSeries', None, writeable=True)
|
|
self._dbusservice.add_path('/System/MinVoltageCellId', None, writeable=True)
|
|
self._dbusservice.add_path('/System/MaxVoltageCellId', None, writeable=True)
|
|
self._dbusservice.add_path("/System/MinTemperatureCellId", None, writeable=True)
|
|
self._dbusservice.add_path("/System/MaxTemperatureCellId", None, writeable=True)
|
|
|
|
self._settings = SettingsDevice(
|
|
bus=dbus.SystemBus() if (platform.machine() == 'armv7l') else dbus.SessionBus(),
|
|
supportedSettings={
|
|
'AvgDischarge': ['/Settings/Batrium/AvgerageDischarge', 0.0,0,0],
|
|
'TotalAhDrawn': ['/Settings/Batrium/TotalAhDrawn', 0.0,0,0],
|
|
'TimeLastFull': ['/Settings/Batrium/TimeLastFull', 0.0,0,0],
|
|
'MinCellVoltage': ['/Settings/Batrium/MinCellVoltage', 0.0,0.0,0.0],
|
|
'MaxCellVoltage': ['/Settings/Batrium/MaxCellVoltage', 0.0,0.0,0.0],
|
|
'TargetChargeVoltage': ['/Settings/Batrium/TargetChargeVoltage', 0.0,0.0,0.0],
|
|
'interval': ['/Settings/Batrium/Interval', 200, 200, 200]
|
|
},
|
|
eventCallback=handle_changed_setting)
|
|
|
|
self._summeditems = {
|
|
'/System/MaxCellVoltage': {'gettext': '%.3F V'},
|
|
'/System/MinCellVoltage': {'gettext': '%.3F V'},
|
|
'/Dc/0/Voltage': {'gettext': '%.2F V'},
|
|
'/Dc/0/Current': {'gettext': '%.2F A'},
|
|
'/Dc/0/Power': {'gettext': '%.0F W'},
|
|
'/Soc': {'gettext': '%.0F%%'},
|
|
'/Soh': {'gettext': '%.0F%%'},
|
|
'/History/TotalAhDrawn': {'gettext': '%.0F Ah'},
|
|
'/History/DischargedEnergy': {'gettext': '%.2F kWh'},
|
|
'/History/ChargedEnergy': {'gettext': '%.2F kWh'},
|
|
'/History/AverageDischarge': {'gettext': '%.2F kWh'},
|
|
'/TimeToGo': {'gettext': '%.0F s'},
|
|
'/ConsumedAmphours': {'gettext': '%.1F Ah'},
|
|
'/System/MinCellTemperature': {'gettext': '%.1F °C'},
|
|
'/System/MaxCellTemperature': {'gettext': '%.1F °C'},
|
|
'/Capacity': {'gettext': '%.1F Ah'},
|
|
'/InstalledCapacity': {'gettext': '%.1F Ah'},
|
|
'/Info/MaxChargeVoltage': {'gettext': '%.1F V'},
|
|
'/Info/MaxChargeCurrent': {'gettext': '%.1F A'},
|
|
'/Info/MaxDischargeCurrent': {'gettext': '%.1F A'}
|
|
}
|
|
|
|
for path in self._summeditems.keys():
|
|
self._dbusservice.add_path(path, value=None, gettextcallback=self._gettext)
|
|
|
|
## Load settings from Venus OS config xml ##
|
|
self._dbusservice['/History/AverageDischarge'] = self._settings['AvgDischarge']
|
|
self._dbusservice['/History/TotalAhDrawn'] = self._settings['TotalAhDrawn']
|
|
self._dbusservice.add_path('/History/TimeSinceLastFullCharge', 0)
|
|
self._dbusservice.add_path('/History/MinCellVoltage', self._settings['MinCellVoltage'])
|
|
self._dbusservice.add_path('/History/MaxCellVoltage', self._settings['MaxCellVoltage'])
|
|
|
|
## Set variables I will use later to standard values ##
|
|
self._dbusservice['/Soh'] = 100
|
|
self._dbusservice['/ConsumedAmphours'] = 0
|
|
## Set CCL to 1 amp temporarily, it will overwritte immediately after first message, suppresing BMS missing after script crash ##
|
|
self._dbusservice['/Info/MaxChargeCurrent'] = 1
|
|
## Set SOC according to Batrium as init values, if Cerbo or script is restarted at 100% SOC
|
|
if self._bat.soc <= 99:
|
|
self._dbusservice['/Soc'] = self._bat.soc
|
|
else:
|
|
self._dbusservice['/Soc'] = 100
|
|
|
|
## Log values written to history/XML ##
|
|
logging.debug("History cell voltage min: %.3f, max: %.3f, totalAhDrawn: %d", self._settings['MinCellVoltage'], self._settings['MaxCellVoltage'], self._settings['TotalAhDrawn'])
|
|
|
|
GLib.timeout_add( self._settings['interval'], exit_on_error, self._update)
|
|
|
|
def _gettext(self, path, value):
|
|
item = self._summeditems.get(path)
|
|
if item is not None:
|
|
return item['gettext'] % value
|
|
return str(value)
|
|
|
|
def __del__(self):
|
|
self._safe_history()
|
|
logging.info('Stopping dbus-batrium-native integration')
|
|
|
|
def _safe_history(self):
|
|
logging.debug('Saving history to localsettings')
|
|
self._settings['AvgDischarge'] = self._dbusservice['/History/AverageDischarge']
|
|
self._settings['TotalAhDrawn'] = self._dbusservice['/History/TotalAhDrawn']
|
|
self._settings['MinCellVoltage'] = self._dbusservice['/History/MinCellVoltage']
|
|
self._settings['MaxCellVoltage'] = self._dbusservice['/History/MaxCellVoltage']
|
|
self._settings['TargetChargeVoltage'] = self._dbusservice['/Info/MaxChargeVoltage']
|
|
|
|
def _daily_stats(self):
|
|
## Update daily statistics and reset energy counters
|
|
if (self._dbusservice['/History/DischargedEnergy'] == 0): return
|
|
logging.debug("Updating stats, SOC: %d, Discharged: %.2f, Charged: %.2f ",self._bat.soc, self._dbusservice['/History/DischargedEnergy'], self._dbusservice['/History/ChargedEnergy'])
|
|
self._dbusservice['/History/AverageDischarge'] = (6*self._dbusservice['/History/AverageDischarge'] + self._dbusservice['/History/DischargedEnergy'])/7 #rolling week
|
|
self._dbusservice['/History/ChargedEnergy'] = 0
|
|
self.ChargedEnergy = 0
|
|
self._dbusservice['/History/DischargedEnergy'] = 0
|
|
self.DischargedEnergy = 0
|
|
self.dailyResetDone = datetime.now().day
|
|
|
|
def _update(self):
|
|
time = datetime.now()
|
|
self.lastUpdated = time.timestamp()
|
|
|
|
## Monitor communication ##
|
|
if (self._bat.updated != -1 and self.lastUpdated == 0) or ((self.lastUpdated - self._bat.updated) < 10):
|
|
self._dbusservice['/Connected'] = 1
|
|
else:
|
|
self._dbusservice['/Connected'] = 0
|
|
|
|
## Call daily statistics and reset energy counters function
|
|
if datetime.now().hour == 6 and datetime.now().minute == 0 and datetime.now().day != self.dailyResetDone :
|
|
self._daily_stats()
|
|
|
|
## Alarms ##
|
|
if self._bat.alarm_high_temperature:
|
|
self._dbusservice['/Alarms/HighTemperature'] = 2
|
|
else:
|
|
self._dbusservice['/Alarms/HighTemperature'] = 0
|
|
if self._bat.alarm_low_temperature:
|
|
self._dbusservice['/Alarms/LowTemperature'] = 2
|
|
else:
|
|
self._dbusservice['/Alarms/LowTemperature'] = 0
|
|
if self._bat.alarm_low_voltage:
|
|
self._dbusservice['/Alarms/LowVoltage'] = 2
|
|
else:
|
|
self._dbusservice['/Alarms/LowVoltage'] = 0
|
|
if self._bat.alarm_high_voltage:
|
|
self._dbusservice['/Alarms/HighVoltage'] = 2
|
|
else:
|
|
self._dbusservice['/Alarms/HighVoltage'] = 0
|
|
if self._bat.alarm_high_charge_current:
|
|
self._dbusservice['/Alarms/HighChargeCurrent'] = 2
|
|
else:
|
|
self._dbusservice['/Alarms/HighChargeCurrent'] = 0
|
|
if self._bat.alarm_high_discharge_current:
|
|
self._dbusservice['/Alarms/HighDischargeCurrent'] = 2
|
|
else:
|
|
self._dbusservice['/Alarms/HighDischargeCurrent'] = 0
|
|
|
|
## State of Charge, Batrium couting SoC above 100, stay at 99 till all cells are balanced, then set timestamp and SoC to 100 ##
|
|
if self._bat.soc <= 99:
|
|
self._dbusservice['/Soc'] = self._bat.soc
|
|
dt = datetime.now() - datetime.fromtimestamp( float(self._settings['TimeLastFull']) )
|
|
self._dbusservice['/History/TimeSinceLastFullCharge'] = (dt.seconds + dt.days * 24 * 3600)
|
|
elif (self._bat.soc > 99) and (self.cell_balanced):
|
|
self._dbusservice['/Soc'] = 100
|
|
self._dbusservice['/ConsumedAmphours'] = 0
|
|
self._settings['TimeLastFull'] = time()
|
|
|
|
## Cells are balancing or not ##
|
|
if self._bat.NumberInBypass != 0:
|
|
self._dbusservice['/Balancing'] = 1
|
|
else:
|
|
self._dbusservice['/Balancing'] = 0
|
|
|
|
## Write Batrium values direct to Venus OS registers ##
|
|
self._dbusservice['/Dc/0/Current'] = self._bat.current
|
|
self._dbusservice['/Dc/0/Voltage'] = self._bat.voltage
|
|
power = self._bat.voltage * self._bat.current
|
|
self._dbusservice['/Dc/0/Power'] = power
|
|
self._dbusservice['/Dc/0/Temperature'] = self._bat.maxCellTemperature
|
|
self._dbusservice['/Info/MaxChargeCurrent'] = self._bat.maxChargeCurrent
|
|
self._dbusservice['/Info/MaxDischargeCurrent'] = self._bat.maxDischargeCurrent
|
|
self._dbusservice['/System/NrOfModulesOnline'] = self._bat.numberOfModules
|
|
self._dbusservice['/System/NrOfBatteriesBalancing'] = self._bat.NumberInBypass
|
|
self._dbusservice['/System/BatteriesSeries'] = self._bat.numberOfModules
|
|
self._dbusservice['/InstalledCapacity'] = self._bat.capacity
|
|
self._dbusservice['/Capacity'] = self._bat.capacity
|
|
|
|
## Set Charge Voltage Limit according to Batrium, if charging is disabled, Batrium sent 0.0V. Stay at last CVL and save it to Venus OS config xml, to workaround if restarted with charge off ##
|
|
if self._bat.maxChargeVoltage != 0:
|
|
self._dbusservice['/Info/MaxChargeVoltage'] = self._bat.maxChargeVoltage
|
|
self.maxChargeVoltage = self._bat.maxChargeVoltage
|
|
# If all cells are balanced, lower CVL 0.1V to spare cells mons
|
|
elif self.maxChargeVoltage != 0:
|
|
self._dbusservice['/Info/MaxChargeVoltage'] = self.maxChargeVoltage - 0.1
|
|
elif self.maxChargeVoltage == 0 and self._bat.maxChargeVoltage == 0:
|
|
self._dbusservice['/Info/MaxChargeVoltage'] = self._settings['TargetChargeVoltage']
|
|
|
|
## Calculation every minute ##
|
|
now = datetime.now().time()
|
|
if now.minute != self.minUpdateDone:
|
|
self.minUpdateDone = now.minute
|
|
|
|
## Display min and max cell temperatures every minute, because of better readability
|
|
self._dbusservice['/System/MinCellTemperature'] = self._bat.minCellTemperature
|
|
self._dbusservice['/System/MaxCellTemperature'] = self._bat.maxCellTemperature
|
|
self._dbusservice['/System/MinTemperatureCellId'] = self._bat.minCellTemperatureId
|
|
self._dbusservice['/System/MaxTemperatureCellId'] = self._bat.maxCellTemperatureId
|
|
|
|
## Same for cell voltages and saving to history
|
|
self._dbusservice['/System/MaxCellVoltage'] = self._bat.maxCellVoltage
|
|
if (self._bat.maxCellVoltage > self._dbusservice['/History/MaxCellVoltage'] ):
|
|
self._dbusservice['/History/MaxCellVoltage'] = self._bat.maxCellVoltage
|
|
logging.debug("New maximum cell voltage: %f", self._bat.maxCellVoltage)
|
|
|
|
self._dbusservice['/System/MinCellVoltage'] = self._bat.minCellVoltage
|
|
if (0 < self._bat.minCellVoltage < self._dbusservice['/History/MinCellVoltage'] ):
|
|
self._dbusservice['/History/MinCellVoltage'] = self._bat.minCellVoltage
|
|
logging.debug("New minimum cell voltage: %f", self._bat.minCellVoltage)
|
|
|
|
self._dbusservice['/System/MaxVoltageCellId'] = self._bat.maxCellVoltageId
|
|
self._dbusservice['/System/MinVoltageCellId'] = self._bat.minCellVoltageId
|
|
|
|
# Time remaining to full and to empty, show None if under 1 amp and under 5 days left for nicer looking readings
|
|
if self._bat.current > 1:
|
|
#charging
|
|
if self._bat.TimeToFull < 432000:
|
|
self._dbusservice['/TimeToGo'] = self._bat.TimeToFull
|
|
else:
|
|
self._dbusservice['/TimeToGo'] = None
|
|
elif self._bat.current < -1:
|
|
#discharging
|
|
self._dbusservice['/ConsumedAmphours'] += abs(self._bat.current * 0.016667) #Ah
|
|
self._dbusservice['/History/TotalAhDrawn'] += abs(self._bat.current * 0.016667) #Ah
|
|
if self._bat.TimeToEmpty < 432000:
|
|
self._dbusservice['/TimeToGo'] = self._bat.TimeToEmpty
|
|
else:
|
|
self._dbusservice['/TimeToGo'] = None
|
|
else :
|
|
self._dbusservice['/TimeToGo'] = None
|
|
|
|
## Check if all cells are balancing
|
|
if self._bat.NumberInBypass == self._bat.numberOfModules:
|
|
self.cell_balanced = True
|
|
elif self._bat.NumberInBypass == 0:
|
|
self.cell_balanced = False
|
|
|
|
## Call history save function to write history items to Venus OS config xml
|
|
self._safe_history()
|
|
|
|
## Calculation every second ##
|
|
if now.second != self.secUpdateDone:
|
|
self.secUpdateDone = now.second
|
|
# Calculated charged and discharged energy and save it to history, because Batrium not sending
|
|
if power > 0:
|
|
self.ChargedEnergy += (power / 3600.0) / 1000
|
|
if power < 0:
|
|
self.DischargedEnergy += (power / 3600.0) / 1000
|
|
self._dbusservice['/History/ChargedEnergy'] = abs(self.ChargedEnergy)
|
|
self._dbusservice['/History/DischargedEnergy'] = abs(self.DischargedEnergy)
|
|
|
|
return True
|
|
|
|
def main():
|
|
## Cli parser to set interface and for debbuging purposes
|
|
parser = ArgumentParser(description='dbus-batrium-native integration', add_help=True)
|
|
parser.add_argument('-d', '--debug', help='enable debug logging', action='store_true')
|
|
parser.add_argument('-i', '--interface', help='CAN interface')
|
|
parser.add_argument('-p', '--print', help='print only')
|
|
|
|
args = parser.parse_args()
|
|
|
|
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
|
|
datefmt='%Y-%m-%d %H:%M:%S',
|
|
level=(logging.DEBUG if args.debug else logging.INFO),
|
|
handlers=[
|
|
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
|
|
logging.StreamHandler()
|
|
])
|
|
|
|
if not args.interface:
|
|
logging.info('No CAN interface specified, using default can0')
|
|
args.interface = 'can0'
|
|
|
|
logging.info('Starting dbus-batrium-native integration %s on %s ' % (VERSION, args.interface))
|
|
|
|
from dbus.mainloop.glib import DBusGMainLoop
|
|
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
|
|
DBusGMainLoop(set_as_default=True)
|
|
|
|
battery_output = DbusBatteryService(
|
|
servicename='com.victronenergy.battery',
|
|
connection = args.interface,
|
|
deviceinstance = 0,
|
|
)
|
|
|
|
logging.debug('Connected to dbus, and switching over to GLib.MainLoop() (= event based)')
|
|
mainloop = GLib.MainLoop()
|
|
mainloop.run()
|
|
|
|
if __name__ == "__main__":
|
|