VictronGX_Custom_Sensors/dbus-node-red-temp-outside/temp_outside.py

159 lines
5.6 KiB
Python

#!/usr/bin/env python
# import normal packages
import platform
import logging
import sys
import os
import sys
if sys.version_info.major == 2:
import gobject
else:
from gi.repository import GLib as gobject
import sys
import time
import requests # for http GET
# our own packages from victron
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '/opt/victronenergy/dbus-systemcalc-py/ext/velib_python'))
from vedbus import VeDbusService
class NodeRedMeterTemperature:
def __init__(self, servicename, deviceinstance, paths, productname='External temp sensor', connection='Node RED HTTP JSON service'):
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
self._paths = paths
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
# Create the management objects, as specified in the ccgx dbus-api document
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Python ' + platform.python_version())
self._dbusservice.add_path('/Mgmt/Connection', connection)
# Create the mandatory objects
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
self._dbusservice.add_path('/ProductId', 0xA162) #from dbus spy with wire attached sensor
self._dbusservice.add_path('/FilterLength', 10)
self._dbusservice.add_path('/Offset', 0)
self._dbusservice.add_path('/Scale', 1)
self._dbusservice.add_path('/ProductName', productname)
self._dbusservice.add_path('/CustomName', "Temperatur Außen")
self._dbusservice.add_path('/TemperatureType', 2) # 0=battery; 1=fridge; 2=generic
self._dbusservice.add_path('/FirmwareVersion', 1.0)
self._dbusservice.add_path('/HardwareVersion', 0)
self._dbusservice.add_path('/Connected', 1)
self._dbusservice.add_path('/Serial', 1337)
self._dbusservice.add_path('/UpdateIndex', 0)
# add path values to dbus
for path, settings in self._paths.items():
self._dbusservice.add_path(
path, settings['initial'], gettextcallback=settings['textformat'], writeable=True, onchangecallback=self._handlechangedvalue)
# last update
self._lastUpdate = 0
# add _update function 'timer'
gobject.timeout_add(2000, self._update) # pause 2000ms before the next request
# add __Status 'timer' to get feedback in log every 5minutes
gobject.timeout_add(self._get_StatusInterval()*60*1000, self.__Status)
def _get_StatusInterval(self):
value = 1
if not value:
value = 0
return int(value)
def _getNodeRedData(self):
URL = "http://localhost:1880/temps"
temperature_r = requests.get(url = URL)
# check for response
if not temperature_r:
raise ConnectionError("No response from NodeRed - %s" % (URL))
meter_data = temperature_r.json()
# check for Json
if not meter_data:
raise ValueError("Converting response to JSON failed")
return meter_data
def __Status(self):
logging.info("Last _update: %s" % (self._lastUpdate))
logging.info("Last '/Temperature': %s" % (self._dbusservice['/Temperature']))
return True
def _update(self):
try:
#get data from NodeRed 3em
meter_data = self._getNodeRedData()
#send data to DBus
self._dbusservice['/Temperature'] = meter_data['outside']
#logging
logging.debug("Temperature Outside (/Temperature): %s" % (self._dbusservice['/Temperature']))
logging.debug("---");
# increment UpdateIndex - to show that new data is available
index = self._dbusservice['/UpdateIndex'] + 1 # increment index
if index > 255: # maximum value of the index
index = 0 # overflow from 255 to 0
self._dbusservice['/UpdateIndex'] = index
#update lastupdate vars
self._lastUpdate = time.time()
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
# return true, otherwise add_timeout will be removed from GObject - see docs http://library.isr.ist.utl.pt/docs/pygtk2reference/gobject-functions.html#function-gobject--timeout-add
return True
def _handlechangedvalue(self, path, value):
logging.debug("someone else updated %s to %s" % (path, value))
return True # accept the change
def main():
#configure logging
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
datefmt='%Y-%m-%d %H:%M:%S',
level=logging.INFO,
handlers=[
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
logging.StreamHandler()
])
try:
logging.info("Start");
from dbus.mainloop.glib import DBusGMainLoop
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
#formatting
_celcius = lambda p, v: (str(round(v, 2)) + ' °C')
#start our main-service
pvac_output = NodeRedMeterTemperature(
servicename='com.victronenergy.temperature',
deviceinstance=18,
paths={
'/Temperature': {'initial': 0, 'textformat': _celcius},
})
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
mainloop = gobject.MainLoop()
mainloop.run()
except Exception as e:
logging.critical('Error at %s', 'main', exc_info=e)
if __name__ == "__main__":
main()