#!/usr/bin/env python # import normal packages import platform import logging import sys import os import sys if sys.version_info.major == 2: import gobject else: from gi.repository import GLib as gobject import sys import time import requests # for http GET # our own packages from victron sys.path.insert(1, os.path.join(os.path.dirname(__file__), '/opt/victronenergy/dbus-systemcalc-py/ext/velib_python')) from vedbus import VeDbusService class NodeRedMeterTemperature: def __init__(self, servicename, deviceinstance, paths, productname='External temp sensor', connection='Node RED HTTP JSON service'): self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance)) self._paths = paths logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance)) # Create the management objects, as specified in the ccgx dbus-api document self._dbusservice.add_path('/Mgmt/ProcessName', __file__) self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Python ' + platform.python_version()) self._dbusservice.add_path('/Mgmt/Connection', connection) # Create the mandatory objects self._dbusservice.add_path('/DeviceInstance', deviceinstance) self._dbusservice.add_path('/ProductId', 0xA162) #from dbus spy with wire attached sensor self._dbusservice.add_path('/FilterLength', 10) self._dbusservice.add_path('/Offset', 0) self._dbusservice.add_path('/Scale', 1) self._dbusservice.add_path('/ProductName', productname) self._dbusservice.add_path('/CustomName', "Temperatur Außen") self._dbusservice.add_path('/TemperatureType', 2) # 0=battery; 1=fridge; 2=generic self._dbusservice.add_path('/FirmwareVersion', 1.0) self._dbusservice.add_path('/HardwareVersion', 0) self._dbusservice.add_path('/Connected', 1) self._dbusservice.add_path('/Serial', 1337) self._dbusservice.add_path('/UpdateIndex', 0) # add path values to dbus for path, settings in self._paths.items(): self._dbusservice.add_path( path, settings['initial'], gettextcallback=settings['textformat'], writeable=True, onchangecallback=self._handlechangedvalue) # last update self._lastUpdate = 0 # add _update function 'timer' gobject.timeout_add(2000, self._update) # pause 2000ms before the next request # add _Status 'timer' to get feedback in log every 5minutes gobject.timeout_add(self._getStatusInterval()*60*1000, self._Status) def _getStatusInterval(self): value = 1 if not value: value = 0 return int(value) def _getNodeRedData(self): URL = "http://localhost:1880/temps" temperature_r = requests.get(url = URL) # check for response if not temperature_r: raise ConnectionError("No response from NodeRed - %s" % (URL)) meter_data = temperature_r.json() # check for Json if not meter_data: raise ValueError("Converting response to JSON failed") return meter_data def _Status(self): logging.info("Last _update: %s" % (self._lastUpdate)) logging.info("Last '/Temperature': %s" % (self._dbusservice['/Temperature'])) return True def _update(self): try: #get data from NodeRed 3em meter_data = self._getNodeRedData() #send data to DBus self._dbusservice['/Temperature'] = meter_data['outside'] #logging logging.debug("Temperature Outside (/Temperature): %s" % (self._dbusservice['/Temperature'])) logging.debug("---"); # increment UpdateIndex - to show that new data is available index = self._dbusservice['/UpdateIndex'] + 1 # increment index if index > 255: # maximum value of the index index = 0 # overflow from 255 to 0 self._dbusservice['/UpdateIndex'] = index #update lastupdate vars self._lastUpdate = time.time() except Exception as e: logging.critical('Error at %s', '_update', exc_info=e) # return true, otherwise add_timeout will be removed from GObject - see docs http://library.isr.ist.utl.pt/docs/pygtk2reference/gobject-functions.html#function-gobject--timeout-add return True def _handlechangedvalue(self, path, value): logging.debug("someone else updated %s to %s" % (path, value)) return True # accept the change def main(): #configure logging logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.INFO, handlers=[ logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))), logging.StreamHandler() ]) try: logging.info("Start"); from dbus.mainloop.glib import DBusGMainLoop # Have a mainloop, so we can send/receive asynchronous calls to and from dbus DBusGMainLoop(set_as_default=True) #formatting _celcius = lambda p, v: (str(round(v, 2)) + ' °C') #start our main-service pvac_output = NodeRedMeterTemperature( servicename='com.victronenergy.temperature', deviceinstance=18, paths={ '/Temperature': {'initial': 0, 'textformat': _celcius}, }) logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)') mainloop = gobject.MainLoop() mainloop.run() except Exception as e: logging.critical('Error at %s', 'main', exc_info=e) if __name__ == "__main__": main()