FIRMWARES | ||
RDFlasher.exe | ||
Readme.md |
New options in "Quick Settings" (Shift + Down)
- "GreenTerm=>Out" - If ENABLE then the GREEN terminal will work as an output over relay (NOTE! In this mode the battery detection is disabled, so no charger mode).
- "UCP" - Under Current Protection. Disables the output if the current falls below the set value. (Working only in Power Supply mode, no affect in charger mode)
- "UCP Trigger" - If enabled, the "UCP" option will be activated only after the current reaches the set value.
- In option "External LED" added new item "VG/CY/OxP", what means: CV-Green, CC-Yellow, OxP (any protection Blinking RED)
- The "UCP" and "UCP Trigger" options are also available in the "--- Power Settings ---"