PowerStationMonitor/openhab2/items/dc_supply.items

23 lines
3.5 KiB
Plaintext

Group gDC_Supply "DC Labornetzgerät, Riden RD6018, 60V 18A"
Number DC_Supply_Voltage "Spannung [%.2f V]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:voltage_actual:number", expire="1m,0"}
Number DC_Supply_Current "Strom [%.2f A]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:current_actual:number", expire="1m,0"}
Number DC_Supply_Input_Voltage "Eingangsspannung [%.2f V]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:voltage_input:number", expire="1m,0"}
Number DC_Supply_Protection "Sicherheitsabschaltung [MAP(dc_supply_protection.map):%s]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:protection:number", expire="1m,0"}
Number DC_Supply_Amperehours "Amperestunden [%.3f Ah]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_sec:ampere_hours:number", expire="1m,0"}
Number DC_Supply_Watthours "Wattstunden [%.3f Wh]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_sec:watt_hours:number", expire="1m,0"}
Number DC_Supply_Power "Leistung [%.1f W]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:power:number", expire="1m,0"}
Number DC_Supply_Mode "Modus [MAP(dc_supply_mode.map):%s]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:mode:number", expire="1m,0"}
Number DC_Supply_Voltage_Setpoint "Spannungs Sollwert [%.2f V]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:voltage_setpoint:number", expire="1m,0"}
Number DC_Supply_Current_Setpoint "Strom Sollwert [%.2f A]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:current_setpoint:number", expire="1m,0"}
Number DC_Supply_PowerOnOff "Lastausgang schalten" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:output_enable:number", expire="1m,0"}
Number DC_Supply_Temp_Internal "Temperatur Intern [%.0f °C]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_main:temperature_internal:number", expire="1m,0"}
Number DC_Supply_Temp_External "Temperatur Extern [%.0f °C]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_sec:temperature_external:number", expire="1m,0"}
Number DC_Supply_Temp_External_Active (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_sec:temperature_external_active:number", expire="1m,0"}
Number DC_Supply_Batt_Active "Batterielademodus [MAP(dc_supply_battmode.map):%s]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_sec:battery_mode_active:number", expire="1m,0"}
Number DC_Supply_Batt_Voltage "Batteriespannung [%.2f V]" (gDC_Supply) {channel="modbus:data:dcsupply:dcsupply_sec:voltage_battery:number", expire="1m,0"}
Number DC_Supply_Timer "Timer [%.0f s]" (gDC_Supply)
Switch DC_Supply_Set_Reset "Zähler zurücksetzen" (gDC_Supply)