Zoe was charging while locked and I stopped charging with my wallbox.
No polling was active at this state. Interesting....
Try1:
I (20114294) v-zoe-ph2-obd: PID:18daf1db DATA: 07 62 92 43 00 32 5d c9
0x9243 Cumulated energy in charge (Zxx_kwh_chg)
Data: 0x00325dc9 --> 3300809 x 0.001 -> 3300,809 kWh
I (20114894) v-zoe-ph2-obd: PID:18daf1db DATA: 05 62 90 01 1c 30 aa aa
0x9001 Battery SOC(Zxx_bsoc_avg)
Data: 0x1c30 --> 7216 --> 72,16%
I (20115494) v-zoe-ph2-obd: PID:18daf1db DATA: 05 62 91 bc 03 e8 aa aa
I (20116094) v-zoe-ph2-obd: PID:18daf1db DATA: 05 62 91 bd 03 e8 aa aa
I (20150984) v-zoe-ph2-obd: PID:18daf1da DATA: 06 62 20 06 00 4d d4 aa
Try2:
I (21594984) v-zoe-ph2-obd: PID:18daf1da DATA: 06 62 20 06 00 4d d4 aa
I (21634064) v-zoe-ph2-obd: PID:18daf1db DATA: 07 62 92 43 00 32 5d c9
I (21634664) v-zoe-ph2-obd: PID:18daf1db DATA: 05 62 90 01 1c 2b aa aa
I (21635264) v-zoe-ph2-obd: PID:18daf1db DATA: 05 62 91 bc 03 e8 aa aa
I (21635864) v-zoe-ph2-obd: PID:18daf1db DATA: 05 62 91 bd 03 e8 aa aa
Wirehshark Dump with ISOTP and UDS decoding:
DataRead.Parking history (T°Max/BSOC)(Zxx_prk_mtrx)
Data Identifier: 0x91d2
Data Record: 0000000000000000000000020004000200000000005b00a100b0001d000000bd015801ba…
It is a heatmap on whic temperature the akku pack stays in which temperature. Look at screenshot /DDT/LBC/LBC Stats.png