OVMS3/Reference/DDT/INV/INV_0220_A50_V1.0_20200115T151643.xml

7727 lines
379 KiB
XML

<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="http://www-diag.intra.renault.fr/DDT2000/DDTECUPreview.xsl"?>
<xml xmlns:ddt="http://www-diag.renault.com/2002/ECU">
<Generator name="DDT2000 XML library" version="2.2.0.0" date="2020-01-09T16:29"/>
<ddt:Target Name="INV_0220_A50_V1.0" xmlns="http://www-diag.renault.com/2002/ECU" xmlns:ds="http://www-diag.renault.com/2002/screens" email="blaize.mathew-extern@rntbci.com" href="INV_0220_A50_V1.0_20200115T151643.xml" upload="1/15/2020" group="INV"><Description><![CDATA[Auteur: Adina JOITA
a_dg_dgt_dat_magdia2_inv_xx_e_a(24.1).xls
DTC list: a_dg_dft_cfg_failxxx_inv_xx_e_a(11.0).xls
History
---------------------------------
INV_0220_A50_V1.0(MBL):
Added Vdiag $07 - 0220_A500;
Added project XFK;
Added DTC
- STTR_TEMP_EL HMB $A2A LB $01 with description " Stator temperature sensors "
- STTR_TEMP_FAIL HMB $A2A LB $91 with description " Stator temperature sensors "
Updated description of the DID $70F1;
INV_0220_A40_V1.1(SMA):
-Modified Auto ident 0220_A40 VDiag $07_change GL4 to BGP because of changing of supplier.
INV_0220_A40_V1.0(CDI):
-Added Auto ident 0220_A40 VDiag $07
-Update DIDs: $70A2, $70F0;
-Added DIDs: $2000; $2060; $7000; $7020; $702A; $702C; $7040; $7060; $7080; $7090; $70A0; $70C0; $70E0; $70EF;
INV_0220_A32_V1.0 (AJO):
Added Auto ident 0220_A32 VDiag $07
INV_0220_A32_V1.0 (AJO):
Added Auto ident 0220_A32 VDiag $16
Added DIDs $70F0 $70F1 $70F2 $70F3
Added screen "Conditions for mesures Ratio capteur"
INV_0220_A21_V2.0 (AJO):
-Added name DTC $0908-"CAN communication with battery"
INV_0220_A21_V1.0 (AJO):
Added DTC $0908 FT $61
Updated DTCFailureType.ManufacturerOrSupplier
INV_0220_700_V1.0->INV_0220_A16_V1.0 (AJO)
-Added DIDs: $70E8 $70E9 $70EA $70EB $70EC $70ED $70EE
INV_0220_A15_V1.0 (AJO)
->Auto Ident for 0220_A150/A160/A170/A180/A190/A200/A210/A300/A310 VDIAG $16
->Added DIDs $70D5, $70D6, $70D7, $70D8, $70E7
->Added X10ph2
-----Tool to ECU extended -> 18DADFF1
---- ECU to Tool extended -> 18DAF1DF
2021-9-23 Identification added by tool (CORP\ay11058) => DiagVersion=17, Supplier=BGP, Soft=0220, Version=A600
]]></Description>
<Projects xmlns=""><x10Ph2/><xFK/></Projects><Checks Version="V1.10" Date="20200115T151222">
<Ctrl Type="DDT2000" Warning="501" Error="0"/>
<Ctrl Type="CPDD" Warning="225" Error="0"/>
<Ctrl Type="DAIMLER-ODX" Warning="499" Error="0"/>
<Ctrl Type="ALLIANCE-ODX" Warning="3" Error="0"/>
</Checks>
<Function Name="INV-ME_29b" Address="223"/>
<Language Name="Français" Reference="1"/>
<DateOfficialisation>17-12-2019 11:55:35</DateOfficialisation>
<Failures Name="DTC Failures" Id="3"/>
<PowerSupply>
<Ground/>
<Vbat/>
<AfterContact/>
</PowerSupply>
<CAN BaudRate="10400" Multipoint="1">
<SendId>
<CANId Value="416997361" Extended="1"/>
</SendId>
<ReceiveId>
<CANId Value="417001951" Extended="1"/>
</ReceiveId>
</CAN>
<AutoIdents>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A150"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A160"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A170"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A180"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A190"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A200"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A210"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A300"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A310"/>
<AutoIdent DiagVersion="22" Supplier="GL4" Soft="0220" Version="A320"/>
<AutoIdent DiagVersion="7" Supplier="GL4" Soft="0220" Version="A320"/>
<AutoIdent DiagVersion="7" Supplier="BGP" Soft="0220" Version="A400"/>
<AutoIdent DiagVersion="7" Supplier="BGP" Soft="0220" Version="A500"/>
<AutoIdent DiagVersion="17" Supplier="BGP" Soft="0220" Version="A600"/></AutoIdents>
<Datas>
<Data Name="StatusOfDTC">
<Mnemonic>DTCASR_SODTC</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="DTCStatus.testFailed">
<Mnemonic>TF</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No"/>
<Item Value="1" Text="Yes"/>
</List>
</Bits>
</Data>
<Data Name="DTCStatus.testFailedThisMonitoringCycle">
<Mnemonic>TFTMC</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No"/>
<Item Value="1" Text="Yes"/>
</List>
</Bits>
</Data>
<Data Name="DTCStatus.pendingDTC">
<Mnemonic>PDTC</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No"/>
<Item Value="1" Text="Yes"/>
</List>
</Bits>
</Data>
<Data Name="DTCStatus.confirmedDTC">
<Mnemonic>CDTC</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No"/>
<Item Value="1" Text="Yes"/>
</List>
</Bits>
</Data>
<Data Name="DTCStatus.testNotCompletedSinceLastClear">
<Mnemonic>TNCSLC</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No"/>
<Item Value="1" Text="Yes"/>
</List>
</Bits>
</Data>
<Data Name="DTCStatus.testFailedSinceLastClear">
<Mnemonic>TFSLC</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No"/>
<Item Value="1" Text="Yes"/>
</List>
</Bits>
</Data>
<Data Name="DTCStatus.testNotCompletedThisMonitoringCycle">
<Mnemonic>TNCTMC</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No"/>
<Item Value="1" Text="Yes"/>
</List>
</Bits>
</Data>
<Data Name="DTCStatus.warningIndicatorRequested">
<Mnemonic>WIR</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No"/>
<Item Value="1" Text="Yes"/>
</List>
</Bits>
</Data>
<Data Name="DTCFailureType.Category">
<Bits count="4">
<List>
<Item Value="0" Text="General Failure Information"/>
<Item Value="1" Text="General Electrical Failures"/>
<Item Value="2" Text="General Signal Failures"/>
<Item Value="3" Text="FM (Frequency Modulated) / PWM (Pulse Width Modulated) Failures"/>
<Item Value="4" Text="System Internal Failures"/>
<Item Value="5" Text="System Programming Failures"/>
<Item Value="6" Text="Algorithm Based Failures"/>
<Item Value="7" Text="Mechanical Failures"/>
<Item Value="8" Text="Bus Signal / Message Failures"/>
<Item Value="9" Text="Component Failures"/>
<Item Value="15" Text="Vehicle manufacturer / System supplier specific"/>
</List>
</Bits>
</Data>
<Data Name="DTCFailureType">
<Bits>
<List>
<Item Value="0" Text="Device and failure type ODB codding"/>
<Item Value="1" Text="General Electrical Failure"/>
<Item Value="2" Text="General signal failure"/>
<Item Value="3" Text="FM (Frequency Modulated) / PWM (Pulse Width Modulated) Failures"/>
<Item Value="4" Text="System Internal Failures"/>
<Item Value="5" Text="System Programming Failures"/>
<Item Value="6" Text="Algorithm Based Failures"/>
<Item Value="7" Text="Mechanical Failures"/>
<Item Value="8" Text="Bus Signal / Message Failures"/>
<Item Value="9" Text="Component Failures"/>
<Item Value="17" Text="circuit short to ground"/>
<Item Value="18" Text="circuit short to battery"/>
<Item Value="19" Text="circuit open"/>
<Item Value="20" Text="circuit short to ground or open"/>
<Item Value="21" Text="circuit short to battery or open"/>
<Item Value="22" Text="circuit voltage below threshold"/>
<Item Value="23" Text="circuit voltage above threshold"/>
<Item Value="24" Text="circuit current below threshold"/>
<Item Value="25" Text="circuit current above threshold"/>
<Item Value="26" Text="circuit resistance below threshold"/>
<Item Value="27" Text="circuit resistance above threshold"/>
<Item Value="28" Text="circuit voltage out of range"/>
<Item Value="29" Text="circuit current out of range"/>
<Item Value="30" Text="circuit resistance out of range"/>
<Item Value="31" Text="circuit intermittent"/>
<Item Value="33" Text="signal amplitude &lt; minimum"/>
<Item Value="34" Text="signal amplitude &gt; maximum"/>
<Item Value="35" Text="signal stuck low"/>
<Item Value="36" Text="signal stuck high"/>
<Item Value="37" Text="signal shape / waveform failure"/>
<Item Value="38" Text="signal rate of change below threshold"/>
<Item Value="39" Text="signal rate of change above threshold"/>
<Item Value="40" Text="signal bias level out of range / zero adjustment failure"/>
<Item Value="41" Text="signal signal invalid"/>
<Item Value="47" Text="signal erratic"/>
<Item Value="49" Text="no signal"/>
<Item Value="50" Text="signal low time &lt; minimum"/>
<Item Value="51" Text="signal low time &gt; maximum"/>
<Item Value="52" Text="signal high time &lt; minimum"/>
<Item Value="53" Text="signal high time &gt; maximum"/>
<Item Value="54" Text="signal frequency too low"/>
<Item Value="55" Text="signal frequency too high"/>
<Item Value="56" Text="signal frequency incorrect"/>
<Item Value="57" Text="incorrect has too few pulses"/>
<Item Value="58" Text="incorrect has too many pulses"/>
<Item Value="65" Text="general checksum failure"/>
<Item Value="66" Text="general memory failure"/>
<Item Value="67" Text="special memory failure"/>
<Item Value="68" Text="data memory failure"/>
<Item Value="69" Text="program memory failure"/>
<Item Value="70" Text="calibration / parameter memory failure"/>
<Item Value="71" Text="watchdog / safety µC failure"/>
<Item Value="72" Text="supervision software failure"/>
<Item Value="73" Text="internal electronic failure"/>
<Item Value="74" Text="incorrect component installed"/>
<Item Value="75" Text="over temperature"/>
<Item Value="81" Text="not programmed"/>
<Item Value="82" Text="not activated"/>
<Item Value="83" Text="deactivated"/>
<Item Value="84" Text="missing calibration"/>
<Item Value="85" Text="not configured"/>
<Item Value="97" Text="signal calculation failure"/>
<Item Value="98" Text="signal compare failure"/>
<Item Value="99" Text="circuit / component protection time-out"/>
<Item Value="100" Text="signal plausibility failure"/>
<Item Value="101" Text="signal has too few transitions / events"/>
<Item Value="102" Text="signal has too many transitions / events"/>
<Item Value="103" Text="signal incorrect after event"/>
<Item Value="104" Text="event information"/>
<Item Value="113" Text="actuator stuck"/>
<Item Value="114" Text="actuator stuck open"/>
<Item Value="115" Text="actuator stuck closed"/>
<Item Value="116" Text="actuator slipping"/>
<Item Value="117" Text="emergency position not reachable"/>
<Item Value="118" Text="wrong mounting position"/>
<Item Value="119" Text="commanded position not reachable"/>
<Item Value="120" Text="alignment or adjustment incorrect"/>
<Item Value="121" Text="mechanical linkage failure"/>
<Item Value="122" Text="fluid leak or seal failure"/>
<Item Value="123" Text="low fluid level"/>
<Item Value="129" Text="invalid serial data received"/>
<Item Value="130" Text="alive / sequence counter incorrect / not updated"/>
<Item Value="131" Text="value of signal protection calculation incorrect"/>
<Item Value="132" Text="signal below allowable range"/>
<Item Value="133" Text="signal above allowable range"/>
<Item Value="134" Text="signal invalid"/>
<Item Value="135" Text="missing message"/>
<Item Value="136" Text="bus off"/>
<Item Value="143" Text="erratic"/>
<Item Value="145" Text="parametric"/>
<Item Value="146" Text="performance or incorrect operation"/>
<Item Value="147" Text="no operation"/>
<Item Value="148" Text="unexpected operation"/>
<Item Value="149" Text="incorrect assembly"/>
<Item Value="150" Text="component internal failure"/>
<Item Value="151" Text="Component or system operation obstructed or blocked"/>
<Item Value="152" Text="component or system over temperature"/>
<Item Value="251" Text="-"/>
<Item Value="252" Text="--"/>
</List>
</Bits>
</Data>
<Data Name="DTCDeviceIdentifier">
<Bits count="16">
<List>
<Item Value="48" Text="+APC"/>
<Item Value="773" Text="Lithium Battery Controler"/>
<Item Value="774" Text="Charger Controler"/>
<Item Value="779" Text="Boost PWM (between rectifier and inverter modules)"/>
<Item Value="780" Text="BCM (Body Control Module)"/>
<Item Value="781" Text="EVC"/>
<Item Value="782" Text="EVC relays"/>
<Item Value="2049" Text="Inverter"/>
<Item Value="2050" Text="Inverter current sensor"/>
<Item Value="2051" Text="High voltage sensor"/>
<Item Value="2052" Text="Inverter temperature sensor"/>
<Item Value="2053" Text="Inverter temperature"/>
<Item Value="2054" Text="Water temperature"/>
<Item Value="2055" Text="Hardware over voltage protection"/>
<Item Value="2056" Text="Inverter phase"/>
<Item Value="2057" Text="Inverter non traction safety watch"/>
<Item Value="2058" Text="Inverter auto diagnosis"/>
<Item Value="2059" Text="Inverter DFLASH memory corruption"/>
<Item Value="2060" Text="Inverter Reset failure"/>
<Item Value="2064" Text="Inverter driver (high arm)"/>
<Item Value="2065" Text="Inverter driver (low arm)"/>
<Item Value="2066" Text="Inverter driver ready (high arm)"/>
<Item Value="2067" Text="Inverter driver ready (low arm)"/>
<Item Value="2080" Text="Excitation"/>
<Item Value="2081" Text="Excitation current sensor"/>
<Item Value="2082" Text="Excitation temperature sensor"/>
<Item Value="2096" Text="Excitation driver (high arm)"/>
<Item Value="2097" Text="Excitation driver (low arm)"/>
<Item Value="2098" Text="Excitation driver ready"/>
<Item Value="2112" Text="Rotor position speed"/>
<Item Value="2113" Text="Rotor position sensor"/>
<Item Value="2114" Text="PWM Electric Engine command"/>
<Item Value="2115" Text="Safety rotor temperature estimation"/>
<Item Value="2117" Text="Stator temperature sensor 1"/>
<Item Value="2118" Text="Stator temperature sensor 2"/>
<Item Value="2119" Text="Electric engine temperature"/>
<Item Value="2120" Text="Electric engine FAN"/>
<Item Value="2121" Text="Electric engine phase"/>
<Item Value="2122" Text="Rotor position offset learning"/>
<Item Value="2123" Text="Rotor resistance leaning"/>
<Item Value="2128" Text="DCDC High voltage side"/>
<Item Value="2129" Text="DCDC low voltage side"/>
<Item Value="2130" Text="DCDC driver"/>
<Item Value="2132" Text="DCDC"/>
<Item Value="2144" Text="ECU monitoring (Watchdog)"/>
<Item Value="2145" Text="ECU monitoring (Safety torque estimation)"/>
<Item Value="2146" Text="SPI communication"/>
<Item Value="2147" Text="Supply monitoring"/>
<Item Value="2148" Text="Main controler temperature sensor"/>
<Item Value="2149" Text="PCB controler temperature sensor"/>
<Item Value="2151" Text="Power supply 2.1"/>
<Item Value="2152" Text="Driver board temperature sensor"/>
<Item Value="2160" Text="High voltage network"/>
<Item Value="2176" Text="Voltage supply A11"/>
<Item Value="2312" Text="CAN communication with battery"/>
<Item Value="2602" Text="Stator temperature sensors"/>
</List>
</Bits>
</Data>
<Data Name="DTCDeviceAndFailureTypeOBD">
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="DTCFailureType.ManufacturerOrSupplier">
<Bits count="4">
<List>
<Item Value="1" Text="Safety Case 1"/>
<Item Value="2" Text="Safety Case 2"/>
<Item Value="3" Text="Multiple Failure"/>
<Item Value="4" Text="Temperature too Low"/>
<Item Value="5" Text="Negative Loop Error"/>
<Item Value="6" Text="Positive Loop Error"/>
<Item Value="7" Text="Initialisation not valid"/>
<Item Value="8" Text="Overspeed"/>
<Item Value="9" Text="Limp Home"/>
<Item Value="10" Text="Specific Supplier"/>
<Item Value="13" Text="Drift low"/>
<Item Value="14" Text="Drift high"/>
</List>
</Bits>
</Data>
<Data Name="DTCStatusAvailabilityMask">
<Mnemonic>DTCSAM</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="DTCMaskRecord">
<Mnemonic>DTCMREC_DTC</Mnemonic>
<Bytes count="3"/>
</Data>
<Data Name="DTCRecord">
<Mnemonic>DTCASR_DTC</Mnemonic>
<Bytes count="3"/>
</Data>
<Data Name="DTCExtendedData.AgingCounter">
<Comment><![CDATA[Description of the extendedData AgingCounter (use by Failure Page to decode data)]]></Comment>
<Mnemonic>AGINGCOUNTER</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="DTCExtendedDataRecordNumber">
<Mnemonic>DTCEDRN</Mnemonic>
<Bits>
<List>
<Item Value="128" Text="Mileage"/>
<Item Value="129" Text="AgingCounter"/>
<Item Value="130" Text="DTCOccurrenceCounter"/>
<Item Value="132" Text="DTCOccurrenceCounter_2"/>
<Item Value="133" Text="DTCLastDiseappearMileage"/>
<Item Value="134" Text="DTCTravelledDistanceFailurePresent"/>
<Item Value="135" Text="DTCFirstAppearMileage"/>
</List>
</Bits>
</Data>
<Data Name="DTCExtendedData.DTCOccurrenceCounter">
<Comment><![CDATA[Description of the extendedData DTCOccurenceCounter (use by Failure Page to decode data)]]></Comment>
<Mnemonic>DTCOCCURENCECOUNTER</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="DTCExtendedData.DTCOccurrenceCounter_2">
<Comment><![CDATA[Description of the extendedData DTCOccurenceCounter (use by Failure Page to decode data)]]></Comment>
<Mnemonic>DTCOCCURENCECOUNTER:Stx_frq_dyn</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="DTCExtendedData.DTCLastDiseappearMileage">
<Comment><![CDATA[Description of the extendedData Mileage (use by Failure Page to decode data)]]></Comment>
<Mnemonic>MILEAGE:Stx_km_pass_dyn</Mnemonic>
<Bits count="24">
<Scaled Unit="km"/>
</Bits>
</Data>
<Data Name="DTCExtendedData.DTCTravelledDistanceFailurePresent">
<Comment><![CDATA[Description of the extendedData Mileage (use by Failure Page to decode data)]]></Comment>
<Mnemonic>MILEAGE:Stx_dist_fail_dyn</Mnemonic>
<Bits count="24">
<Scaled Unit="km"/>
</Bits>
</Data>
<Data Name="DTCExtendedData.DTCFirstAppearMileage">
<Comment><![CDATA[Description of the extendedData Mileage (use by Failure Page to decode data)]]></Comment>
<Mnemonic>MILEAGE:Stx_km_mf_dyn</Mnemonic>
<Bits count="24">
<Scaled Unit="km"/>
</Bits>
</Data>
<Data Name="CalibrationNumber">
<Comment><![CDATA[Numero de calibration en Hexa]]></Comment>
<Mnemonic>NCAL</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="DiagnosticIdentificationCode">
<Comment><![CDATA[Diag evolution number]]></Comment>
<Mnemonic>VDIAG</Mnemonic>
<Bytes count="1"/>
</Data>
<Data Name="SoftwareNumber">
<Comment><![CDATA[Software identification number]]></Comment>
<Mnemonic>NPGRGM</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="SupplierNumber.ITG">
<Comment><![CDATA[Supplier ITG code]]></Comment>
<Mnemonic>NFOUR</Mnemonic>
<Bytes count="3" ascii="1"/>
</Data>
<Data Name="EditionNumber">
<Comment><![CDATA[Software version(edition) number]]></Comment>
<Mnemonic>NVERS</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="PartNumber.BasicPartList">
<Bits>
<List>
<Item Value="0" Text="N/A"/>
<Item Value="1" Text="292A6"/>
<Item Value="2" Text="29170"/>
</List>
</Bits>
</Data>
<Data Name="HardwareNumber.BasicPartList">
<Bits>
<List>
<Item Value="0" Text="N/A"/>
<Item Value="1" Text="292A6"/>
</List>
</Bits>
</Data>
<Data Name="ApprovalNumber.BasicPartList">
<Bits>
<List>
<Item Value="0" Text="N/A"/>
<Item Value="1" Text="HMLGT"/>
</List>
</Bits>
</Data>
<Data Name="PartNumber.LowerPart">
<Bytes count="5" ascii="1"/>
</Data>
<Data Name="HardwareNumber.LowerPart">
<Bytes count="5" ascii="1"/>
</Data>
<Data Name="ManufacturerIdentificationCode">
<Bits>
<List>
<Item Value="0" Text="Renault R1"/>
<Item Value="128" Text="Nissan N1"/>
<Item Value="129" Text="Nissan N2"/>
<Item Value="130" Text="Nissan N3"/>
<Item Value="136" Text="5DIGITS"/>
<Item Value="255" Text="Renault R3"/>
</List>
</Bits>
</Data>
<Data Name="ApprovalNumber.LowerPart">
<Bytes count="5" ascii="1"/>
</Data>
<Data Name="ProgrammingSiteReference">
<Bytes count="5" ascii="1"/>
</Data>
<Data Name="ProgrammingToolReference">
<Bytes count="5" ascii="1"/>
</Data>
<Data Name="NumberOfReprogrammings">
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="DateOfReprogramming">
<Comment><![CDATA[date of the reprogramming yy.mm.dd]]></Comment>
<Bytes count="3"/>
</Data>
<Data Name="SaveMarking">
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="CrcOfLogSave">
<Bytes count="2"/>
</Data>
<Data Name="TimeOfReprogramming">
<Comment><![CDATA[Hour, Minute of the reprogramming]]></Comment>
<Bytes count="2"/>
</Data>
<Data Name="RoutineEntryOption">
<Comment><![CDATA[= "Routine" input parameters]]></Comment>
<Mnemonic>RENTOPT1</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Start"/>
<Item Value="1" Text="Status"/>
</List>
</Bits>
</Data>
<Data Name="RoutineEntryStatus">
<Mnemonic>RENTSTAT1</Mnemonic>
<Bits>
<List>
<Item Value="1" Text="In progress"/>
<Item Value="2" Text="Complete and OK"/>
<Item Value="3" Text="Complete and not OK"/>
</List>
</Bits>
</Data>
<Data Name="Output Temporary Control List">
<Bits>
<List>
<Item Value="65" Text="PEC fan"/>
</List>
</Bits>
</Data>
<Data Name="Output Control Command">
<Comment><![CDATA[Control option parameter definition]]></Comment>
<Bits>
<List>
<Item Value="0" Text="Start Temporary"/>
<Item Value="1" Text="Status request"/>
<Item Value="17" Text="Stop Control"/>
</List>
</Bits>
</Data>
<Data Name="Output Temporary Control List-answer">
<Bits>
<List>
<Item Value="65" Text="PEC fan"/>
</List>
</Bits>
</Data>
<Data Name="Output Control Status">
<Bits>
<List>
<Item Value="1" Text="Running"/>
<Item Value="2" Text="Stopped"/>
<Item Value="17" Text="Manually Stopped"/>
<Item Value="18" Text="Stopped abnormally"/>
<Item Value="32" Text="Conditions not fulfilled"/>
<Item Value="34" Text="Uncoherent tool request"/>
</List>
</Bits>
</Data>
<Data Name="RoutineLocalIdentifierStart">
<Mnemonic>Request_Routine_Choice</Mnemonic>
<Bits>
<List>
<Item Value="7" Text="Static Test"/>
<Item Value="19" Text="Position sensor learning"/>
<Item Value="33" Text="Monitool"/>
</List>
</Bits>
</Data>
<Data Name="RoutineLocalIdentifierStart-answer">
<Mnemonic>Request_Routine_Choice</Mnemonic>
<Bits>
<List>
<Item Value="7" Text="Static Test"/>
<Item Value="19" Text="Position sensor learning"/>
<Item Value="33" Text="Monitool"/>
</List>
</Bits>
</Data>
<Data Name="RoutineExitOption">
<Mnemonic>REXITOPT1</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="RoutineLocalIdentifierStop">
<Mnemonic>Request_Routine_Choice</Mnemonic>
<Bits>
<List>
<Item Value="19" Text="Position sensor learning"/>
<Item Value="33" Text="Monitool"/>
</List>
</Bits>
</Data>
<Data Name="RoutineExitStatus">
<Mnemonic>REXITSTAT1</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Routine stopped"/>
<Item Value="1" Text="Routine in progress"/>
<Item Value="2" Text="Routine complete and OK"/>
<Item Value="3" Text="Routine complete and NOK"/>
</List>
</Bits>
</Data>
<Data Name="RoutineLocalIdentifierStop-answer">
<Mnemonic>Request_Routine_Choice</Mnemonic>
<Bits>
<List>
<Item Value="19" Text="Position sensor learning"/>
<Item Value="33" Text="Monitool"/>
</List>
</Bits>
</Data>
<Data Name="ITG Supplier Number">
<Bytes count="3"/>
</Data>
<Data Name="Traceability Factory Code">
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Traceability Serial Number">
<Bytes count="12" ascii="1"/>
</Data>
<Data Name="CRC">
<Comment><![CDATA[Vehicle Identification Number Checksum]]></Comment>
<Mnemonic>VIN_CKS</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="V.I.N">
<Comment><![CDATA[Vehicle Identification Number : 17 bytes]]></Comment>
<Mnemonic>VIN_i</Mnemonic>
<Bytes count="17" ascii="1"/>
</Data>
<Data Name="DTCExtendedData.Mileage">
<Comment><![CDATA[Description of the extendedData Mileage (use by Failure Page to decode data)]]></Comment>
<Mnemonic>MILEAGE</Mnemonic>
<Bits count="24">
<Scaled Unit="km"/>
</Bits>
</Data>
<Data Name="Configuration of Electrical Vehicle Networks">
<Comment><![CDATA[Configuration of Electrical Vehicle Networks]]></Comment>
<Bytes count="11"/>
</Data>
<Data Name="List of Electrical Vehicle ECUs with After-sales diagnostic">
<Comment><![CDATA[List of Electrical Vehicle ECUs with After-sales diagnostic]]></Comment>
<Bytes count="11"/>
</Data>
<Data Name="Hardware Part Number 1">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 2">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 3">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 4">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 5">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 6">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 7">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 8">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 9">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Hardware Part Number 10">
<Comment><![CDATA[Daimler Hardware Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 1">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 2">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 3">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 4">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 5">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 6">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 7">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 8">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 9">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Software Part Number 10">
<Comment><![CDATA[Daimler Software Part Number]]></Comment>
<Mnemonic>LID $EF</Mnemonic>
<Bytes count="1" ascii="1"/>
</Data>
<Data Name="Vin In Ascii">
<Comment><![CDATA[VIN readen in generic frame $2181]]></Comment>
<Mnemonic>VIN_IN_ASCII</Mnemonic>
<Bytes count="17" ascii="1"/>
</Data>
<Data Name="Vin CRC">
<Mnemonic>VIN_CRC</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="($2001) Rotor mechanical rotation speed">
<Comment><![CDATA[Vxx_emot_n]]></Comment>
<Mnemonic>DID_$2001</Mnemonic>
<Bits count="16">
<Scaled Unit="rpm" Step=" .5" Offset="-16000"/>
</Bits>
</Data>
<Data Name="($2002) Emotor torque estimation, based on measured current values">
<Comment><![CDATA[Vxx_esti_emot_tq]]></Comment>
<Mnemonic>DID_$2002</Mnemonic>
<Bits count="16">
<Scaled Unit="N·m" Step=" .015625" Offset="-254"/>
</Bits>
</Data>
<Data Name="($2003) Torque setpoint from EVC">
<Comment><![CDATA[Vxx_emot_tq_sp]]></Comment>
<Mnemonic>DID_$2003</Mnemonic>
<Bits count="16">
<Scaled Unit="N·m" Step=" .1" Offset="-250"/>
</Bits>
</Data>
<Data Name="($2004) Battery voltage sensor">
<Comment><![CDATA[Vxx_udc]]></Comment>
<Mnemonic>DID_$2004</Mnemonic>
<Bits count="16">
<Scaled Unit="V" Step=" .03125"/>
</Bits>
</Data>
<Data Name="($2005) DCDC output tension measure">
<Comment><![CDATA[Vxx_dcdc_volt_ou_mes_raw]]></Comment>
<Mnemonic>DID_$2005</Mnemonic>
<Bits count="16">
<Scaled Unit="mV"/>
</Bits>
</Data>
<Data Name="($2070) Immobilizer - diagnosis availability">
<Comment><![CDATA[Vbx_swlk_diag_avl]]></Comment>
<Mnemonic>DID_$2070</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="unavailable"/>
<Item Value="1" Text="available"/>
</List>
</Bits>
</Data>
<Data Name="($2071) Immobilizer - Byte 1 used to allow diagnosis">
<Comment><![CDATA[Vxx_swlk_diag_1]]></Comment>
<Mnemonic>DID_$2071</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="($2072) Immobilizer - Byte 2 used to allow diagnosis">
<Comment><![CDATA[Vxx_swlk_diag_2]]></Comment>
<Mnemonic>DID_$2072</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.0">
<Comment><![CDATA[Vxx_swlk_diag_3]]></Comment>
<Mnemonic>DID_$2073_0</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Immobilizer engine running forbidden"/>
<Item Value="1" Text="Immobilizer engine running authorized"/>
</List>
</Bits>
</Data>
<Data Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.1">
<Comment><![CDATA[Vxx_swlk_diag_3]]></Comment>
<Mnemonic>DID_$2073_1</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Not used"/>
</List>
</Bits>
</Data>
<Data Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.2">
<Comment><![CDATA[Vxx_swlk_diag_3]]></Comment>
<Mnemonic>DID_$2073_2</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Cleappli not set"/>
<Item Value="1" Text="Cleappli set"/>
</List>
</Bits>
</Data>
<Data Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.3">
<Comment><![CDATA[Vxx_swlk_diag_3]]></Comment>
<Mnemonic>DID_$2073_3</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Not used"/>
</List>
</Bits>
</Data>
<Data Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.4">
<Comment><![CDATA[Vxx_swlk_diag_3]]></Comment>
<Mnemonic>DID_$2073_4</Mnemonic>
<Bits count="2">
<List>
<Item Value="0" Text="ECM virgin - Secret key not learnt"/>
<Item Value="1" Text="Not used"/>
<Item Value="2" Text="Not virgin ECM - Secret key learnt in erasable area"/>
<Item Value="3" Text="Not virgin ECM - Secret key learnt in non erasable area"/>
</List>
</Bits>
</Data>
<Data Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.6">
<Comment><![CDATA[Vxx_swlk_diag_3]]></Comment>
<Mnemonic>DID_$2073_6</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="ECM not protected"/>
<Item Value="1" Text="ECM protected"/>
</List>
</Bits>
</Data>
<Data Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.7">
<Comment><![CDATA[Vxx_swlk_diag_3]]></Comment>
<Mnemonic>DID_$2073_7</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Not used"/>
</List>
</Bits>
</Data>
<Data Name="($2074) Immobilizer - engine not running due to ECM">
<Comment><![CDATA[Vbx_swlk_diag_ecm]]></Comment>
<Mnemonic>DID_$2074</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="no"/>
<Item Value="1" Text="yes"/>
</List>
</Bits>
</Data>
<Data Name="($2075) Immobilizer - engine not running due to BCM in secure mode">
<Comment><![CDATA[Vbx_swlk_diag_tool]]></Comment>
<Mnemonic>DID_$2075</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="no"/>
<Item Value="1" Text="yes"/>
</List>
</Bits>
</Data>
<Data Name="($2076) Immobilizer - engine not running due to no BCM authorization">
<Comment><![CDATA[Vbx_swlk_diag_ccu]]></Comment>
<Mnemonic>DID_$2076</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="no"/>
<Item Value="1" Text="yes"/>
</List>
</Bits>
</Data>
<Data Name="($2077) Immobilizer - engine not running due to a CAN network problem with the BCM">
<Comment><![CDATA[Vbx_swlk_diag_mux]]></Comment>
<Mnemonic>DID_$2077</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="no"/>
<Item Value="1" Text="yes"/>
</List>
</Bits>
</Data>
<Data Name="($7001) Command of PEC fan">
<Comment><![CDATA[Vxx_cfa_pwm_sp]]></Comment>
<Mnemonic>DID_$7001</Mnemonic>
<Bits>
<Scaled Unit="%"/>
</Bits>
</Data>
<Data Name="($7002) Wired APC signal">
<Comment><![CDATA[Vbx_dcdc_apc_raw]]></Comment>
<Mnemonic>DID_$7002</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="APC off"/>
<Item Value="1" Text="APC on"/>
</List>
</Bits>
</Data>
<Data Name="($7003) Measured rotor current (sensor 1)">
<Comment><![CDATA[Wxx_i_f_1]]></Comment>
<Mnemonic>DID_$7003</Mnemonic>
<Bits count="16">
<Scaled Unit="A" Step=" .0009765625"/>
</Bits>
</Data>
<Data Name="($7004) Measured rotor current (sensor 2)">
<Comment><![CDATA[Wxx_i_f_2]]></Comment>
<Mnemonic>DID_$7004</Mnemonic>
<Bits count="16">
<Scaled Unit="A" Step=" .0009765625"/>
</Bits>
</Data>
<Data Name="($7005) Verlog Status">
<Comment><![CDATA[Vbx_eng_run_ena_swlk]]></Comment>
<Mnemonic>DID_$7005</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Vehicle locked"/>
<Item Value="1" Text="Vehicle unlocked"/>
</List>
</Bits>
</Data>
<Data Name="($7006) Wire frame APC state">
<Comment><![CDATA[Vbx_wf_apc]]></Comment>
<Mnemonic>DID_$7006</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="APC off"/>
<Item Value="1" Text="APC on"/>
</List>
</Bits>
</Data>
<Data Name="($7007) Measured stator current on phase U">
<Comment><![CDATA[Wxx_i_mot_ph_1]]></Comment>
<Mnemonic>DID_$7007</Mnemonic>
<Bits count="16">
<Scaled Unit="A" Step=" .03125" Offset="-500"/>
</Bits>
</Data>
<Data Name="($7008) Measured stator current on phase V">
<Comment><![CDATA[Wxx_i_mot_ph_2]]></Comment>
<Mnemonic>DID_$7008</Mnemonic>
<Bits count="16">
<Scaled Unit="A" Step=" .03125" Offset="-500"/>
</Bits>
</Data>
<Data Name="($7009) Measured stator current on phase W">
<Comment><![CDATA[Wxx_i_mot_ph_3]]></Comment>
<Mnemonic>DID_$7009</Mnemonic>
<Bits count="16">
<Scaled Unit="A" Step=" .03125" Offset="-500"/>
</Bits>
</Data>
<Data Name="($700A) Feedback fan raw diagnostic">
<Comment><![CDATA[Vbx_raw_cfa_nok]]></Comment>
<Mnemonic>DID_$700A</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="OK"/>
<Item Value="1" Text="NOK"/>
</List>
</Bits>
</Data>
<Data Name="($700B) Excitation temperature">
<Comment><![CDATA[Vxx_wf_exct_temp]]></Comment>
<Mnemonic>DID_$700B</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Step=" .001953125" Offset="-40"/>
</Bits>
</Data>
<Data Name="($700C) Inverter temperature sensor 1">
<Comment><![CDATA[Vxx_wf_invt_temp_1]]></Comment>
<Mnemonic>DID_$700C</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Step=" .001953125" Offset="-40"/>
</Bits>
</Data>
<Data Name="($700D) MICRO temperature">
<Comment><![CDATA[Vxx_wf_mc_temp]]></Comment>
<Mnemonic>DID_$700D</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Step=" .001953125" Offset="-40"/>
</Bits>
</Data>
<Data Name="($700E) PCB temperature">
<Comment><![CDATA[Vxx_wf_pcb_temp]]></Comment>
<Mnemonic>DID_$700E</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Step=" .001953125" Offset="-40"/>
</Bits>
</Data>
<Data Name="($700F) Stator temperature sensor 1">
<Comment><![CDATA[Vxx_sttr_temp_1]]></Comment>
<Mnemonic>DID_$700F</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Step=" .001953125" Offset="-40"/>
</Bits>
</Data>
<Data Name="($7010) Stator temperature sensor 2">
<Comment><![CDATA[Vxx_sttr_temp_2]]></Comment>
<Mnemonic>DID_$7010</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Step=" .001953125" Offset="-40"/>
</Bits>
</Data>
<Data Name="($7011) Raw rotor position resolver angular position measurement">
<Comment><![CDATA[Wxx_sens_emot_psn_raw]]></Comment>
<Mnemonic>DID_$7011</Mnemonic>
<Bits count="16">
<Scaled Unit="°" Step=" .0078125"/>
</Bits>
</Data>
<Data Name="($7012) Status flag of the Smartcoder">
<Comment><![CDATA[Wxx_sens_emot_psn_sf]]></Comment>
<Mnemonic>DID_$7012</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="($7013) Raw rotor position resolver cosine voltage">
<Comment><![CDATA[Wxx_sens_emot_psn_raw_cos_0]]></Comment>
<Mnemonic>DID_$7013</Mnemonic>
<Bits count="16">
<Scaled Unit="V" Step=" .0002441406"/>
</Bits>
</Data>
<Data Name="($7014) Raw rotor position resolver cosine voltage with 25µs delay">
<Comment><![CDATA[Wxx_sens_emot_psn_raw_cos_25]]></Comment>
<Mnemonic>DID_$7014</Mnemonic>
<Bits count="16">
<Scaled Unit="V" Step=" .0002441406"/>
</Bits>
</Data>
<Data Name="($7015) Raw rotor position resolver excitation peak voltage">
<Comment><![CDATA[Wxx_sens_emot_psn_raw_exc]]></Comment>
<Mnemonic>DID_$7015</Mnemonic>
<Bits count="16">
<Scaled Unit="V" Step=" .0002441406"/>
</Bits>
</Data>
<Data Name="($7017) Failure vector allowing exact identification of the failure.1">
<Comment><![CDATA[Vxx_dcdc_diag_1]]></Comment>
<Mnemonic>DID_$7017</Mnemonic>
<Bits count="16">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($7018) Failure vector allowing exact identification of the failure.2">
<Comment><![CDATA[Vxx_dcdc_diag_2]]></Comment>
<Mnemonic>DID_$7018</Mnemonic>
<Bits>
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($7019) Failure vector allowing exact identification of the failure.3">
<Comment><![CDATA[Vxx_dcdc_diag_3]]></Comment>
<Mnemonic>DID_$7019</Mnemonic>
<Bits>
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($701A) Failure vector allowing exact identification of the failure.4">
<Comment><![CDATA[Vxx_dcdc_diag_4]]></Comment>
<Mnemonic>DID_$701A</Mnemonic>
<Bits count="16">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($701B) Failure vector allowing exact identification of the DCDC event">
<Comment><![CDATA[Vxx_dcdc_diag_5]]></Comment>
<Mnemonic>DID_$701B</Mnemonic>
<Bits>
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($701C) Saved rotor position offset.value">
<Comment><![CDATA[Sxx_emot_psn_ofs]]></Comment>
<Mnemonic>DID_$701C_1</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="($701C) Saved rotor position offset.CRC">
<Comment><![CDATA[Sxx_emot_psn_ofs]]></Comment>
<Mnemonic>DID_$701C_2</Mnemonic>
<Bytes count="1"/>
</Data>
<Data Name="($701C) Saved rotor position offset.value.physical">
<Comment><![CDATA[Sxx_emot_psn_ofs]]></Comment>
<Mnemonic>DID_$701C_Phys</Mnemonic>
<Bits count="16">
<Scaled DivideBy=" 128"/>
</Bits>
</Data>
<Data Name="($701D) Counter of FAN fail times to cool the machine stator in hard conditions.1">
<Comment><![CDATA[Sxx_fan_nok_fail_1]]></Comment>
<Mnemonic>DID_$701D</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($701E) Counter of FAN fail times to cool the machine stator in hard conditions.2">
<Comment><![CDATA[Sxx_fan_nok_fail_2]]></Comment>
<Mnemonic>DID_$701E</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($701F) Counter of FAN fail times to cool the machine stator in hard conditions.3">
<Comment><![CDATA[Sxx_fan_nok_fail_3]]></Comment>
<Mnemonic>DID_$701F</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($7058) 1s average dcdc temperature on break event for post mortem">
<Comment><![CDATA[Sxx_pm_dcdc_temp_brk_moy]]></Comment>
<Mnemonic>DID_$7058</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7059) 1s average driver board temperature on break event for post mortem">
<Comment><![CDATA[Sxx_pm_dri_temp_brk_moy]]></Comment>
<Mnemonic>DID_$7059</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($705D) 1s average excitation temperature on break event for post mortem">
<Comment><![CDATA[Sxx_pm_exct_temp_brk_moy]]></Comment>
<Mnemonic>DID_$705D</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($705E) 1s average inverter temperature on break event for post mortem">
<Comment><![CDATA[Sxx_pm_invt_temp_brk_moy]]></Comment>
<Mnemonic>DID_$705E</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($705F) 1s average pcb temperature on break event for post mortem">
<Comment><![CDATA[Sxx_pm_pcb_temp_brk_moy]]></Comment>
<Mnemonic>DID_$705F</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7043) activated downgraded mode FPGA number">
<Comment><![CDATA[Wsx_dm_act_fpga]]></Comment>
<Mnemonic>DID_$7043</Mnemonic>
<Bits count="4">
<List>
<Item Value="0" Text="Nsx_no_sfty_dfl : no downgraded mode"/>
<Item Value="1" Text="Nsx_gc_md_01a : GC-MD01a"/>
<Item Value="2" Text="Nsx_gc_md_01b : GC-MD01b"/>
<Item Value="3" Text="Nsx_gc_md_01c : GC-MD01c"/>
<Item Value="4" Text="Nsx_gc_md_01d : GC-MD01d"/>
<Item Value="5" Text="Nsx_gc_md_01e : GC-MD01e"/>
<Item Value="6" Text="Nsx_gc_ci_md_01a ( 9 ) : gc_ci_md_01a"/>
<Item Value="7" Text="Nsx_gc_ci_md_01b (10) : gc_ci_md_01b"/>
<Item Value="8" Text="Nsx_dfl_chr_md (11) : inconsistency between PWMs and downgraded mode"/>
<Item Value="9" Text="Nsx_dfl_auto_diag_sfty_2 (12) :autodiag safety 2 fpga NOK"/>
</List>
</Bits>
</Data>
<Data Name="($7044) activated downgraded mode number">
<Comment><![CDATA[Wsx_dm_act_sfty]]></Comment>
<Mnemonic>DID_$7044</Mnemonic>
<Bits count="4">
<List>
<Item Value="0" Text="Nsx_no_sfty_dfl : no downgraded mode"/>
<Item Value="1" Text="Nsx_gc_md_01a : GC-MD01a"/>
<Item Value="2" Text="Nsx_gc_md_01b : GC-MD01b"/>
<Item Value="3" Text="Nsx_gc_md_01c : GC-MD01c"/>
<Item Value="4" Text="Nsx_gc_md_01d : GC-MD01d"/>
<Item Value="5" Text="Nsx_gc_md_01e : GC-MD01e"/>
<Item Value="6" Text="Nsx_gc_md_03 : GC-MD03"/>
<Item Value="7" Text="Nsx_gc_ci_md_01a ( 9 ) : gc_ci_md_01a"/>
<Item Value="8" Text="Nsx_gc_ci_md_01b (10) : gc_ci_md_01b"/>
</List>
</Bits>
</Data>
<Data Name="($7022) Active discharge request from EVC to PEB">
<Comment><![CDATA[Vbx_actv_dchg_req]]></Comment>
<Mnemonic>DID_$7022</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Discharge not requested"/>
<Item Value="1" Text="Discharge requested"/>
</List>
</Bits>
</Data>
<Data Name="($706C) Alim 21 monitoring">
<Comment><![CDATA[Vbx_alim_21_mon]]></Comment>
<Mnemonic>DID_$706C</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($706D) Alim 21 with redundance monitoring">
<Comment><![CDATA[Vbx_alim_21_mon_red]]></Comment>
<Mnemonic>DID_$706D</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($707E) Alimentation 11 state">
<Comment><![CDATA[Vbx_sta_stop_alim_11]]></Comment>
<Mnemonic>DID_$707E</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Stop"/>
<Item Value="1" Text="Start"/>
</List>
</Bits>
</Data>
<Data Name="($707F) Alimentation 21 state">
<Comment><![CDATA[Vbx_sta_stop_alim_21]]></Comment>
<Mnemonic>DID_$707F</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Stop"/>
<Item Value="1" Text="Start"/>
</List>
</Bits>
</Data>
<Data Name="($7067) APC and zero torque time counter for post mortem analysis">
<Comment><![CDATA[Sxx_pm_apc_ztq_t_ctr]]></Comment>
<Mnemonic>DID_$7067</Mnemonic>
<Bits count="32" signed="1">
<Scaled Unit="s"/>
</Bits>
</Data>
<Data Name="($7024) APC state (from CAN)">
<Comment><![CDATA[Vbx_apc_stt]]></Comment>
<Mnemonic>DID_$7024</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="APC off"/>
<Item Value="1" Text="APC on"/>
</List>
</Bits>
</Data>
<Data Name="($702B) Auto Diag enable">
<Comment><![CDATA[Vsx_auto_diag_ena]]></Comment>
<Mnemonic>DID_$702B</Mnemonic>
<Bits count="3">
<List>
<Item Value="0" Text="Nsx_auto_diag_nok (0) : Auto diag not allowed"/>
<Item Value="1" Text="Nsx_auto_diag_apc_off (1) : Auto diag without apc allowed"/>
<Item Value="2" Text="Nsx_auto_diag_apc_on (2) : Auto diag with apc allowed"/>
<Item Value="3" Text="Nsx_auto_diag_sfty_1 (3) : auto diag Safety 1 (DM)"/>
<Item Value="4" Text="Nsx_auto_diag_sfty_2 (4) : auto diag Safety 2 (FPGA)"/>
</List>
</Bits>
</Data>
<Data Name="($705B) Blocked rotor counter for post mortem">
<Comment><![CDATA[Sxx_pm_drt_igbt_ctr]]></Comment>
<Mnemonic>DID_$705B</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($7081) Bypass mode">
<Comment><![CDATA[Vsx_byp_mod]]></Comment>
<Mnemonic>DID_$7081</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Bypass off"/>
<Item Value="1" Text="Only THOCP bypass"/>
<Item Value="2" Text="Torque setpoint bypass"/>
<Item Value="3" Text="TQ setpoint and torque mode bypass"/>
<Item Value="4" Text="Current request bypass"/>
<Item Value="5" Text="Voltage control bypass"/>
<Item Value="6" Text="Voltage control + position/speed bypass"/>
<Item Value="7" Text="Inverter voltage control +excitation current +position/speed bypass"/>
<Item Value="8" Text="RGL duty cycle bypass (in PWM)"/>
<Item Value="9" Text="Voltage control and speed bypass and position emulation"/>
</List>
</Bits>
</Data>
<Data Name="($7092) CAN Etude activation">
<Comment><![CDATA[Sbx_can_etu_ena]]></Comment>
<Mnemonic>DID_$7092</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="deactivated"/>
<Item Value="1" Text="activated"/>
</List>
</Bits>
</Data>
<Data Name="($7066) Charge or non zero torque time counter for post mortem analysis">
<Comment><![CDATA[Sxx_pm_tra_chg_t_ctr]]></Comment>
<Mnemonic>DID_$7066</Mnemonic>
<Bits count="32" signed="1">
<Scaled Unit="s"/>
</Bits>
</Data>
<Data Name="($7025) Charge request from EVC to PEB">
<Comment><![CDATA[Vbx_chg_req]]></Comment>
<Mnemonic>DID_$7025</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No charge requested"/>
<Item Value="1" Text="Charge requested"/>
</List>
</Bits>
</Data>
<Data Name="($7049) Combinated current value on the HV Network of Inverter and Excitation">
<Comment><![CDATA[Wxx_i_pwt]]></Comment>
<Mnemonic>DID_$7049</Mnemonic>
<Bits count="16">
<Scaled Unit="A" Step=" .03125" Offset="-500"/>
</Bits>
</Data>
<Data Name="($7039) Combination of inverter, Excitation, PCB, MC and DRI temperatures, so in %">
<Comment><![CDATA[Vxx_invt_norm_temp]]></Comment>
<Mnemonic>DID_$7039</Mnemonic>
<Bits count="16">
<Scaled Unit="%" DivideBy=" 64"/>
</Bits>
</Data>
<Data Name="($703A) Combination of rotor and stator temperatures, so in %">
<Comment><![CDATA[Vxx_mot_norm_temp]]></Comment>
<Mnemonic>DID_$703A</Mnemonic>
<Bits count="16">
<Scaled Unit="%" DivideBy=" 64"/>
</Bits>
</Data>
<Data Name="($7079) Copy Over voltage protection (before flipflop)">
<Comment><![CDATA[Vbx_pwm_dfl_sfty_mem]]></Comment>
<Mnemonic>DID_$7079</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($708C) Copy Raw rotor position resolver excitation peak voltage">
<Comment><![CDATA[Vxx_sens_emot_psn_raw_exc]]></Comment>
<Mnemonic>DID_$708C</Mnemonic>
<Bits count="16">
<Scaled Unit="V" DivideBy=" 4096"/>
</Bits>
</Data>
<Data Name="($709B) CPU load at 10ms">
<Comment><![CDATA[Vtx_TaskDurationIT_A[12]]]></Comment>
<Mnemonic>DID_$709B</Mnemonic>
<Bits>
<Scaled Unit="µs"/>
</Bits>
</Data>
<Data Name="($7084) DCDC Input current measure">
<Comment><![CDATA[Vxx_dcdc_cur_in_mes_raw]]></Comment>
<Mnemonic>DID_$7084</Mnemonic>
<Bits count="16">
<Scaled Unit="A"/>
</Bits>
</Data>
<Data Name="($7033) DCDC input voltage">
<Comment><![CDATA[Vxx_dcdc_volt_in_mes_raw]]></Comment>
<Mnemonic>DID_$7033</Mnemonic>
<Bits count="16">
<Scaled Unit="V" Step=" .5"/>
</Bits>
</Data>
<Data Name="($7085) DCDC output current measure">
<Comment><![CDATA[Vxx_dcdc_cur_ou_est_raw]]></Comment>
<Mnemonic>DID_$7085</Mnemonic>
<Bits count="16">
<Scaled Unit="A"/>
</Bits>
</Data>
<Data Name="($7086) DCDC power card temperature">
<Comment><![CDATA[Vxx_dcdc_temp_pw_sens]]></Comment>
<Mnemonic>DID_$7086</Mnemonic>
<Bits>
<Scaled Unit="°C"/>
</Bits>
</Data>
<Data Name="($702E) DCDC state">
<Comment><![CDATA[Vsx_dcdc_stt]]></Comment>
<Mnemonic>DID_$702E</Mnemonic>
<Bits count="3">
<List>
<Item Value="0" Text="Init (Nsx_dcdc_stt_ini)"/>
<Item Value="1" Text="Autodiag (Nsx_dcdc_stt_dgt)"/>
<Item Value="2" Text="Reset (Nsx_dcdc_stt_rst)"/>
<Item Value="3" Text="Standby (Nsx_dcdc_stt_stby)"/>
<Item Value="4" Text="Pwer ON (Nsx_dcdc_stt_on)"/>
<Item Value="5" Text="MD1 (Nsx_dcdc_stt_def_mod_1)"/>
<Item Value="6" Text="MD4 on (Nsx_dcdc_stt_def_mod_4_on)"/>
<Item Value="7" Text="MD4 stby (Nsx_dcdc_stt_def_mod_4_stby)"/>
</List>
</Bits>
</Data>
<Data Name="($705A) Derating counter for post mortem">
<Comment><![CDATA[Sxx_pm_drt_ctr]]></Comment>
<Mnemonic>DID_$705A</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($706E) DID for activation of bypass frame">
<Comment><![CDATA[Vbx_byp_frm_act]]></Comment>
<Mnemonic>DID_$706E</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Frame inactivated"/>
<Item Value="1" Text="Frame active"/>
</List>
</Bits>
</Data>
<Data Name="($7023) Effective active discharge feedback to EVC">
<Comment><![CDATA[Vbx_actv_dchg_stt]]></Comment>
<Mnemonic>DID_$7023</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Active Discharge Not In Progress"/>
<Item Value="1" Text="Active Discharge In Progress"/>
</List>
</Bits>
</Data>
<Data Name="($7026) Effective Charge feedback to EVC">
<Comment><![CDATA[Vbx_chg_stt]]></Comment>
<Mnemonic>DID_$7026</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No charge in progress"/>
<Item Value="1" Text="Charging in progress"/>
</List>
</Bits>
</Data>
<Data Name="($7046) Excitation Current Default">
<Comment><![CDATA[Wsx_i_f_dfl_sfty]]></Comment>
<Mnemonic>DID_$7046</Mnemonic>
<Bits count="3">
<List>
<Item Value="0" Text="Nsx_ok (0) : no excitation sensor default"/>
<Item Value="1" Text="Nsx_i_f_dfl_1 (1) : default excitation sensor 1"/>
<Item Value="2" Text="Nsx_i_f_dfl_2 (2) : default excitation sensor 2"/>
<Item Value="3" Text="Nsx_i_f_dfl (3) : unknown excitation sensor default"/>
<Item Value="4" Text="Nsx_i_f_wi_dfl (4) : excitation wire default"/>
</List>
</Bits>
</Data>
<Data Name="($7098) Excitation currents safety check">
<Comment><![CDATA[Wsx_i_f_chk_sfty]]></Comment>
<Mnemonic>DID_$7098</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Both currents are consistent (difference &lt;thershold)"/>
<Item Value="1" Text="both currents are out of range OR the 2 currents are inconsistent (difference &gt; thershold)"/>
<Item Value="2" Text="current from sensor 1 (Vxx_i_f_1) is out of range"/>
<Item Value="3" Text="current from sensor 2 (Vxx_i_f_2) is out of range"/>
</List>
</Bits>
</Data>
<Data Name="($707A) Excitation driver state (ready or not)">
<Comment><![CDATA[Vbx_rdy_exct]]></Comment>
<Mnemonic>DID_$707A</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Not Ready"/>
<Item Value="1" Text="Ready"/>
</List>
</Bits>
</Data>
<Data Name="($706F) Excitation high arm IGBT driver fault">
<Comment><![CDATA[Vbx_exct_flt_dri_h]]></Comment>
<Mnemonic>DID_$706F</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7070) Excitation low arm IGBT driver fault">
<Comment><![CDATA[Vbx_exct_flt_dri_l]]></Comment>
<Mnemonic>DID_$7070</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7073) Excitation over current protection (before flipflop) High">
<Comment><![CDATA[Vbx_ocp_exct_h]]></Comment>
<Mnemonic>DID_$7073</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7074) Excitation over current protection (before flipflop) Low">
<Comment><![CDATA[Vbx_ocp_exct_l]]></Comment>
<Mnemonic>DID_$7074</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($702D) Failure class of the DCDC converter">
<Comment><![CDATA[Vsx_dcdc_err_stt]]></Comment>
<Mnemonic>DID_$702D</Mnemonic>
<Bits count="3">
<List>
<Item Value="0" Text="Nsx_dcdc_err_stt_ok : No Fault type"/>
<Item Value="1" Text="Nsx_dcdc_err_stt_1 : GE-MD1 Class C"/>
<Item Value="2" Text="Nsx_dcdc_err_stt_1_prmt : GE-MD1 Class D"/>
<Item Value="3" Text="Nsx_dcdc_err_stt_2 : Not used"/>
<Item Value="4" Text="Nsx_dcdc_err_stt_3 : GE-MD3"/>
<Item Value="5" Text="Nsx_dcdc_err_stt_4 : GE-MD4"/>
</List>
</Bits>
</Data>
<Data Name="($7030) Failure class of the Inverter">
<Comment><![CDATA[Vsx_invt_flt_typ]]></Comment>
<Mnemonic>DID_$7030</Mnemonic>
<Bits count="3">
<List>
<Item Value="0" Text="Nsx_invt_flt_type_0 (0): no downgraded mode"/>
<Item Value="1" Text="Nsx_invt_flt_type_1 (1): INV Stopped (class C)"/>
<Item Value="2" Text="Nsx_invt_flt_type_2 (2): INV Stopped (class D)"/>
<Item Value="3" Text="Nsx_invt_flt_type_3 (3): not used"/>
<Item Value="4" Text="Nsx_invt_flt_type_4 (4) : Safety Barrier Lost"/>
<Item Value="5" Text="Nsx_invt_flt_type_5 (5) : Alert Service"/>
<Item Value="6" Text="Nsx_invt_flt_type_6 (6) : Charge Stop Alert"/>
</List>
</Bits>
</Data>
<Data Name="($7082) FPGA fault sent by SPI">
<Comment><![CDATA[Vsx_hw_fpga_id]]></Comment>
<Mnemonic>DID_$7082</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="no fault"/>
<Item Value="1" Text="Vbx_invt_flt_dri_l or Vbx_invt_flt_dri_h"/>
<Item Value="2" Text="Vbx_exct_flt_dri_h or Vbx_exct_flt_dri_l"/>
<Item Value="3" Text="Vbx_ovp_udc_mem"/>
<Item Value="4" Text="Vbx_ocp_invt_mem"/>
<Item Value="5" Text="Vbx_ocp_exct_mem"/>
<Item Value="6" Text="Vbx_pwm_dfl_sfty_mem"/>
</List>
</Bits>
</Data>
<Data Name="($708A) FPGA firmware version Identifier">
<Comment><![CDATA[Vxx_fpga_fw_id]]></Comment>
<Mnemonic>DID_$708A</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($709C) Gestion of current sensors">
<Comment><![CDATA[Vsx_pwm_oc_auto_diag]]></Comment>
<Mnemonic>DID_$709C</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No Default"/>
<Item Value="1" Text="Phase open circuit default"/>
<Item Value="2" Text="IGBT open circuit default"/>
</List>
</Bits>
</Data>
<Data Name="($7069) Hardware (by the fpga) overcurrent protection counter for post mortem analysis">
<Comment><![CDATA[Sxx_pm_hw_ocp_invt_ctr]]></Comment>
<Mnemonic>DID_$7069</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($706A) Hardware (by the fpga) overvoltage protection counter for post mortem analysis">
<Comment><![CDATA[Sxx_pm_hw_ovp_ctr]]></Comment>
<Mnemonic>DID_$706A</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($702F) High Voltage Network Default">
<Comment><![CDATA[Vsx_hv_dfl_sfty]]></Comment>
<Mnemonic>DID_$702F</Mnemonic>
<Bits count="4">
<List>
<Item Value="0" Text="Nsx_hv_nok (0): More than one sensor failure"/>
<Item Value="1" Text="Nsx_hv_ok (1): No Default"/>
<Item Value="2" Text="Nsx_hv_udc_dfl (2): HV UDC Failure"/>
<Item Value="3" Text="Nsx_hv_dcdc_dfl (3): HV DCDC voltage sensor Failure"/>
<Item Value="4" Text="Nsx_hv_bat_dfl (4): HV Battery voltage sensor Failure"/>
<Item Value="5" Text="Nsx_hv_nw_loss : HV Network Loss or false relay status information"/>
<Item Value="6" Text="Nsx_hv_bat_cell_ov_dfl : HV battery overvoltage (cell)"/>
<Item Value="7" Text="Nsx_hv_bat_ov_dfl : HV battery overvoltage (pack)"/>
<Item Value="8" Text="Nsx_hv_rly_open_dfl: false open relay status information"/>
</List>
</Bits>
</Data>
<Data Name="($7031) Interlock plug service status, from LBC (condition for reprogramming)">
<Comment><![CDATA[Vsx_lbc_ilck_stt]]></Comment>
<Mnemonic>DID_$7031</Mnemonic>
<Bits count="2">
<List>
<Item Value="0" Text="Closed"/>
<Item Value="1" Text="Opened"/>
<Item Value="2" Text="Unavailable"/>
<Item Value="3" Text="not used"/>
</List>
</Bits>
</Data>
<Data Name="($7083) INV Automation State">
<Comment><![CDATA[Vsx_invt_stt]]></Comment>
<Mnemonic>DID_$7083</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Init"/>
<Item Value="1" Text="Traction"/>
<Item Value="2" Text="Charge"/>
<Item Value="3" Text="Motor Stop"/>
<Item Value="4" Text="Rotor Position Learning"/>
<Item Value="5" Text="Stand By"/>
<Item Value="6" Text="Active Discharge"/>
<Item Value="7" Text="Diag"/>
</List>
</Bits>
</Data>
<Data Name="($7071) Inverter high arm IGBT driver fault">
<Comment><![CDATA[Vbx_invt_flt_dri_h]]></Comment>
<Mnemonic>DID_$7071</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($707B) Inverter high IGBT driver state (ready or not)">
<Comment><![CDATA[Vbx_rdy_invt_h]]></Comment>
<Mnemonic>DID_$707B</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Not Ready"/>
<Item Value="1" Text="Ready"/>
</List>
</Bits>
</Data>
<Data Name="($7072) Inverter low arm IGBT driver fault">
<Comment><![CDATA[Vbx_invt_flt_dri_l]]></Comment>
<Mnemonic>DID_$7072</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($707C) Inverter low IGBT driver state (ready or not)">
<Comment><![CDATA[Vbx_rdy_invt_l]]></Comment>
<Mnemonic>DID_$707C</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Not Ready"/>
<Item Value="1" Text="Ready"/>
</List>
</Bits>
</Data>
<Data Name="($7075) Inverter over current protection (before flipflop) Arm U">
<Comment><![CDATA[Vbx_ocp_invt_u]]></Comment>
<Mnemonic>DID_$7075</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7076) Inverter over current protection (before flipflop) Arm V">
<Comment><![CDATA[Vbx_ocp_invt_v]]></Comment>
<Mnemonic>DID_$7076</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7077) Inverter over current protection (before flipflop) Arm W">
<Comment><![CDATA[Vbx_ocp_invt_w]]></Comment>
<Mnemonic>DID_$7077</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7091) Last driver board temperature on 1s in the minute before break event for post mortem">
<Comment><![CDATA[Sxx_pm_dri_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7091</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($709A) Max CPU load at 10ms">
<Comment><![CDATA[Vtx_TaskMaxDurationIT_A[12]]]></Comment>
<Mnemonic>DID_$709A</Mnemonic>
<Bits>
<Scaled Unit="µs"/>
</Bits>
</Data>
<Data Name="($70A1) Max of 10ms task (Vtx_TaskMaxDurationIT_A[3])">
<Comment><![CDATA[Vxx_invt_rst_ctx_3]]></Comment>
<Mnemonic>DID_$70A1</Mnemonic>
<Bits count="16">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($709F) Max of CPU load in micro-seconds (Vtx_TaskMaxDurationIT_A[12])">
<Comment><![CDATA[Vxx_invt_rst_ctx_2]]></Comment>
<Mnemonic>DID_$709F</Mnemonic>
<Bits count="16">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($7035) Maximal available calculated torque in generator mode">
<Comment><![CDATA[Vxx_emot_max_gen_tq]]></Comment>
<Mnemonic>DID_$7035</Mnemonic>
<Bits>
<Scaled Unit="N·m"/>
</Bits>
</Data>
<Data Name="($7036) Maximal available calculated torque in motor mode">
<Comment><![CDATA[Vxx_emot_max_mot_tq]]></Comment>
<Mnemonic>DID_$7036</Mnemonic>
<Bits>
<Scaled Unit="N·m"/>
</Bits>
</Data>
<Data Name="($7061) Maximum driver board temperature during last derating">
<Comment><![CDATA[Sxx_pm_temp_dri_drt_max]]></Comment>
<Mnemonic>DID_$7061</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7062) Maximum excitation temperature during last derating">
<Comment><![CDATA[Sxx_pm_temp_exct_drt_max]]></Comment>
<Mnemonic>DID_$7062</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($70A5) Maximum instant value of normalized torque for cell overvoltage">
<Comment><![CDATA[Vxx_norm_tq_max_cell_ov_fac]]></Comment>
<Mnemonic>DID_$70A5</Mnemonic>
<Bits count="16">
<Scaled Step=" .0000610352" Offset="-1"/>
</Bits>
</Data>
<Data Name="($70A6) Maximum instant value of normalized torque for temperature derating">
<Comment><![CDATA[Vxx_norm_tq_max_temp]]></Comment>
<Mnemonic>DID_$70A6</Mnemonic>
<Bits count="16">
<Scaled Step=" .0000610352" Offset="-1"/>
</Bits>
</Data>
<Data Name="($70A7) Maximum instant value of normalized torque for voltage derating">
<Comment><![CDATA[Vxx_norm_tq_max_udc]]></Comment>
<Mnemonic>DID_$70A7</Mnemonic>
<Bits count="16">
<Scaled Step=" .0000610352" Offset="-1"/>
</Bits>
</Data>
<Data Name="($7063) Maximum inverter temperature during last derating">
<Comment><![CDATA[Sxx_pm_temp_inv_drt_max]]></Comment>
<Mnemonic>DID_$7063</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($70A3) Maximum normalized torque corresponding to max current saturation value">
<Comment><![CDATA[Vxx_norm_tq_cur_sat_max]]></Comment>
<Mnemonic>DID_$70A3</Mnemonic>
<Bits count="16">
<Scaled Step=" .0000610352" Offset="-1"/>
</Bits>
</Data>
<Data Name="($7064) Maximum pcb temperature during last derating">
<Comment><![CDATA[Sxx_pm_temp_pcb_drt_max]]></Comment>
<Mnemonic>DID_$7064</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7065) Maximum water temperature during last derating">
<Comment><![CDATA[Sxx_pm_wtr_temp_brk_moy]]></Comment>
<Mnemonic>DID_$7065</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($70A8) Minimum instant value of normalized torque for cell overvoltage">
<Comment><![CDATA[Vxx_norm_tq_min_cell_ov_fac]]></Comment>
<Mnemonic>DID_$70A8</Mnemonic>
<Bits count="16">
<Scaled Step=" .0000610352" Offset="-1"/>
</Bits>
</Data>
<Data Name="($70A4) Minimum normalized torque corresponding to max current saturation value">
<Comment><![CDATA[Vxx_norm_tq_cur_sat_min]]></Comment>
<Mnemonic>DID_$70A4</Mnemonic>
<Bits count="16">
<Scaled Step=" .0000610352" Offset="-1"/>
</Bits>
</Data>
<Data Name="($703E) Mode of the power train (motor or generator)">
<Comment><![CDATA[Vbx_emot_mod]]></Comment>
<Mnemonic>DID_$703E</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Motor"/>
<Item Value="1" Text="Generator"/>
</List>
</Bits>
</Data>
<Data Name="($7096) Normalized inverter-Excitation temperature">
<Comment><![CDATA[Vxx_invt_exct_norm_temp]]></Comment>
<Mnemonic>DID_$7096</Mnemonic>
<Bits count="16">
<Scaled Unit="%" DivideBy=" 64"/>
</Bits>
</Data>
<Data Name="($7097) Normalized PCB-Micro_driverboard temperature">
<Comment><![CDATA[Vxx_pcb_mc_dri_norm_temp]]></Comment>
<Mnemonic>DID_$7097</Mnemonic>
<Bits count="16">
<Scaled Unit="%" DivideBy=" 64"/>
</Bits>
</Data>
<Data Name="($7093) Number of Derating CFA functionnal failure 1 cycles saved">
<Comment><![CDATA[Sxx_fan_der_fail_1]]></Comment>
<Mnemonic>DID_$7093</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($7094) Number of Derating CFA functionnal failure 2 cycles saved">
<Comment><![CDATA[Sxx_fan_der_fail_2]]></Comment>
<Mnemonic>DID_$7094</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($7095) Number of Derating CFA functionnal failure 3 cycles saved">
<Comment><![CDATA[Sxx_fan_der_fail_3]]></Comment>
<Mnemonic>DID_$7095</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($70CA) Number of the bloc which has nvrol error">
<Comment><![CDATA[Vxx_inv_nvrol_err_bloc]]></Comment>
<Mnemonic>DID_$70CA</Mnemonic>
<Bits>
<Scaled/>
</Bits>
</Data>
<Data Name="($7087) Observer estimation for stack rotor temperature">
<Comment><![CDATA[Vxx_esti_rot_ac_temp]]></Comment>
<Mnemonic>DID_$7087</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Offset="-5120" DivideBy=" 128"/>
</Bits>
</Data>
<Data Name="($7029) On/Off power train activation request from EVC">
<Comment><![CDATA[Vbx_invt_act]]></Comment>
<Mnemonic>DID_$7029</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Inverter Off"/>
<Item Value="1" Text="Inverter On"/>
</List>
</Bits>
</Data>
<Data Name="($705C) Water overheat temperature counter for post mortem">
<Comment><![CDATA[Sxx_pm_drt_tco_ctr]]></Comment>
<Mnemonic>DID_$705C</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($7027) On/Off request of the DCDC from EVC">
<Comment><![CDATA[Vbx_dcdc_actv_req_evc]]></Comment>
<Mnemonic>DID_$7027</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="DCDC Off"/>
<Item Value="1" Text="DCDC On"/>
</List>
</Bits>
</Data>
<Data Name="($708F) Opening relays wire request">
<Comment><![CDATA[Wbx_wi_hv_rly_open]]></Comment>
<Mnemonic>DID_$708F</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="Not open"/>
<Item Value="1" Text="Open"/>
</List>
</Bits>
</Data>
<Data Name="($70A9) Vxx_invt_rst_ctx_5">
<Comment><![CDATA[Vxx_invt_rst_ctx_5]]></Comment>
<Mnemonic>DID_$70A9</Mnemonic>
<Bits count="16">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.0">
<Comment><![CDATA[Stx_pm_invt_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7055_0</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.1">
<Comment><![CDATA[Stx_pm_invt_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7055_1</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.2">
<Comment><![CDATA[Stx_pm_invt_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7055_2</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.3">
<Comment><![CDATA[Stx_pm_invt_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7055_3</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.4">
<Comment><![CDATA[Stx_pm_invt_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7055_4</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.0">
<Comment><![CDATA[Stx_pm_exct_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7054_0</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.1">
<Comment><![CDATA[Stx_pm_exct_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7054_1</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.2">
<Comment><![CDATA[Stx_pm_exct_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7054_2</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.3">
<Comment><![CDATA[Stx_pm_exct_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7054_3</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.4">
<Comment><![CDATA[Stx_pm_exct_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7054_4</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.0">
<Comment><![CDATA[Stx_pm_dri_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7053_0</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.1">
<Comment><![CDATA[Stx_pm_dri_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7053_1</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.2">
<Comment><![CDATA[Stx_pm_dri_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7053_2</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.3">
<Comment><![CDATA[Stx_pm_dri_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7053_3</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.4">
<Comment><![CDATA[Stx_pm_dri_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7053_4</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.4">
<Comment><![CDATA[Stx_pm_dcdc_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7052_4</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.0">
<Comment><![CDATA[Stx_pm_dcdc_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7052_0</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.1">
<Comment><![CDATA[Stx_pm_dcdc_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7052_1</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.2">
<Comment><![CDATA[Stx_pm_dcdc_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7052_2</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.3">
<Comment><![CDATA[Stx_pm_dcdc_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7052_3</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7050) Value for reference rotor resistance (for safety monitoring)">
<Comment><![CDATA[Sxx_rot_r_ref_sfty]]></Comment>
<Mnemonic>DID_$7050</Mnemonic>
<Bits count="16">
<Scaled Unit="Ohm" Step=" .001953125"/>
</Bits>
</Data>
<Data Name="($7034) Voltage demand for the DCDC converter from the EVC">
<Comment><![CDATA[Vxx_dcdc_volt_sp]]></Comment>
<Mnemonic>DID_$7034</Mnemonic>
<Bits count="16">
<Scaled Unit="mV"/>
</Bits>
</Data>
<Data Name="($703C) Vehicle distance totalizer from EVC">
<Comment><![CDATA[Vxx_vh_dist]]></Comment>
<Mnemonic>DID_$703C</Mnemonic>
<Bits count="24">
<Scaled Unit="km"/>
</Bits>
</Data>
<Data Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.0">
<Comment><![CDATA[Stx_pm_wtr_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7057_0</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.1">
<Comment><![CDATA[Stx_pm_wtr_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7057_1</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.2">
<Comment><![CDATA[Stx_pm_wtr_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7057_2</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.3">
<Comment><![CDATA[Stx_pm_wtr_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7057_3</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.4">
<Comment><![CDATA[Stx_pm_wtr_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7057_4</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.0">
<Comment><![CDATA[Stx_pm_pcb_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7056_0</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.1">
<Comment><![CDATA[Stx_pm_pcb_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7056_1</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.2">
<Comment><![CDATA[Stx_pm_pcb_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7056_2</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.3">
<Comment><![CDATA[Stx_pm_pcb_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7056_3</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.4">
<Comment><![CDATA[Stx_pm_pcb_temp_clk_moy]]></Comment>
<Mnemonic>DID_$7056_4</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($7045) Validity status of the rotor electrical rotation speed">
<Comment><![CDATA[Wsx_emot_n_dfl_sfty]]></Comment>
<Mnemonic>DID_$7045</Mnemonic>
<Bits count="2">
<List>
<Item Value="0" Text="Nsx_emot_n_chk_ok: OK"/>
<Item Value="1" Text="Nsx_emot_n_chk_fail: Rotor speed is based on backup position acquisition, increased noise."/>
<Item Value="2" Text="Nsx_emot_n_full_fail: No reliable position inforamtion to compute rotor speed or incoherency between functional and safety rotation speeds"/>
</List>
</Bits>
</Data>
<Data Name="($7048) Validity status of the rotor electrical angular position">
<Comment><![CDATA[Wsx_theta_dfl_sfty]]></Comment>
<Mnemonic>DID_$7048</Mnemonic>
<Bits count="2">
<List>
<Item Value="0" Text="Nsx_dgt_emot_psn_chk_ok: OK"/>
<Item Value="1" Text="Nsx_dgt_emot_psn_chk_fail: Failure of the functional position acquisition"/>
<Item Value="2" Text="Nsx_dgt_emot_psn_chk_fail_sfty: Failure of the safety position acquisition"/>
<Item Value="3" Text="Nsx_dgt_emot_psn_chk_full_fail: Double failure or incoherency between functional and safety positions"/>
</List>
</Bits>
</Data>
<Data Name="($7032) Torque Default">
<Comment><![CDATA[Vsx_tq_dfl_sfty]]></Comment>
<Mnemonic>DID_$7032</Mnemonic>
<Bits count="4">
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="CAN Default"/>
<Item Value="2" Text="Safety Check Default"/>
<Item Value="3" Text="&quot;Unexpected braking&quot; is detected by the &quot;static control strategy&quot;"/>
<Item Value="4" Text="&quot;Unexpected acceleration&quot; in case of negative torque request is detected by the &quot;static control strategy&quot;"/>
<Item Value="5" Text="&quot;Unexpected acceleration&quot; is detected by the &quot;static control strategy&quot;"/>
<Item Value="6" Text="&quot;Unexpected acceleration&quot; is detected by the &quot;dynamic control strategy&quot;"/>
<Item Value="7" Text="&quot;Over braking&quot; is detected by the &quot;static control strategy&quot;"/>
<Item Value="8" Text="&quot;Over braking&quot; or &quot;Unexpected braking&quot; are detected by the &quot;dynamic control strategy&quot;"/>
<Item Value="9" Text="&quot;Lack of motricity&quot; is detected by the &quot;static control strategy&quot;"/>
<Item Value="10" Text="&quot;Lack of motricity&quot; is detected by the &quot;dynamic control strategy&quot;"/>
<Item Value="11" Text="&quot;Loss of regenerative torque&quot; is detected by the &quot;static control strategy&quot;"/>
<Item Value="12" Text="&quot;Loss of regenerative torque&quot; is detected by the &quot;dynamic control strategy&quot;"/>
<Item Value="13" Text="Non zero generated torque detected in case of overvoltage"/>
<Item Value="14" Text="Non limited torque detected in case of rotor overtemperature (rotor temperature = 100%)"/>
</List>
</Bits>
</Data>
<Data Name="($7078) Over voltage protection (before flipflop)">
<Comment><![CDATA[Vbx_ovp_udc]]></Comment>
<Mnemonic>DID_$7078</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7047) Phase Current Default">
<Comment><![CDATA[Wsx_i_mot_ph_dfl_sfty]]></Comment>
<Mnemonic>DID_$7047</Mnemonic>
<Bits count="4">
<List>
<Item Value="0" Text="Nsx_ok (0) : no sensor default"/>
<Item Value="1" Text="Nsx_i_mot_ph_dfl_1 (1) : default phase sensor 1"/>
<Item Value="2" Text="Nsx_i_mot_ph_dfl_2 (2) : default phase sensor 2"/>
<Item Value="3" Text="Nsx_i_mot_ph_dfl_3 (3) : default phase sensor 3"/>
<Item Value="4" Text="Nsx_i_mot_ph_dfl (4) : unknown phase sensor default"/>
<Item Value="5" Text="Nsx_i_mot_ph_wi_dfl_1 (5) : phase wire 1 default"/>
<Item Value="6" Text="Nsx_i_mot_ph_wi_dfl_2 (6) : phase wire 2 default"/>
<Item Value="7" Text="Nsx_i_mot_ph_wi_dfl_3 (7) : phase wire 3 default"/>
<Item Value="8" Text="Nsx_i_mot_ph_wi_dfl (8) : unknown phase wire default"/>
<Item Value="9" Text="Nsx_i_mot_ph_igbt_dfl (9) : unknown IBGT default"/>
</List>
</Bits>
</Data>
<Data Name="($7099) Phase currents safety check">
<Comment><![CDATA[Wsx_i_mot_ph_chk_sfty]]></Comment>
<Mnemonic>DID_$7099</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="the summ of the 3 currents is close to zero (&lt; threshold)"/>
<Item Value="1" Text="the summ of the 3 currents isn't close to zero (&gt;threshold) OR at least 2 of the currents are out of range"/>
<Item Value="2" Text="current from sensor 1 (Vxx_i_mot_ph_1) is out of range"/>
<Item Value="3" Text="current from sensor 2 (Vxx_i_mot_ph_2) is out of range"/>
<Item Value="4" Text="current from sensor 3 (Vxx_i_mot_ph_3) is out of range"/>
</List>
</Bits>
</Data>
<Data Name="($7051) Position sensor type">
<Comment><![CDATA[Sbx_sens_emot_psn_typ]]></Comment>
<Mnemonic>DID_$7051</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="0: Sensor type A = TAMAGAWA"/>
<Item Value="1" Text="1: Sensor type B = MINEBEA"/>
</List>
</Bits>
</Data>
<Data Name="($704C) Received rotor reference resistance CRC">
<Comment><![CDATA[Vxx_rot_r_ref_crc_rcp]]></Comment>
<Mnemonic>DID_$704C</Mnemonic>
<Bytes count="1"/>
</Data>
<Data Name="($704B) Received TETA position offset">
<Comment><![CDATA[Vxx_emot_psn_ofs_rcp]]></Comment>
<Mnemonic>DID_$704B</Mnemonic>
<Bits count="16">
<Scaled DivideBy=" 128"/>
</Bits>
</Data>
<Data Name="($704D) Received value for reference rotor resistance">
<Comment><![CDATA[Vxx_rot_r_ref_rcp]]></Comment>
<Mnemonic>DID_$704D</Mnemonic>
<Bits count="16">
<Scaled Unit="Ohm" Offset=" 512" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($709D) redundant supply 21 failure counter for post mortem analysis">
<Comment><![CDATA[Sxx_pm_alim_21_red_ctr]]></Comment>
<Mnemonic>DID_$709D</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($703B) Resistance rotor learning + CRC written by diag tool.1">
<Comment><![CDATA[Vxx_rot_r_ref_rcp]]></Comment>
<Mnemonic>DID_$703B_1</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="($703B) Resistance rotor learning + CRC written by diag tool.2">
<Comment><![CDATA[Vxx_rot_r_ref_crc_rcp]]></Comment>
<Mnemonic>DID_$703B_2</Mnemonic>
<Bytes count="1"/>
</Data>
<Data Name="($7088) Rotor copper temperature estimation">
<Comment><![CDATA[Vxx_esti_rot_cu_temp]]></Comment>
<Mnemonic>DID_$7088</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Offset="-5120" DivideBy=" 128"/>
</Bits>
</Data>
<Data Name="($7038) Rotor copper temperature raw estimation">
<Comment><![CDATA[Vxx_esti_rot_cu_temp_raw]]></Comment>
<Mnemonic>DID_$7038</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .0078125" Offset="-40"/>
</Bits>
</Data>
<Data Name="($7041) Rotor overcurrent validated">
<Comment><![CDATA[Wbx_sw_ocp_exct_mem]]></Comment>
<Mnemonic>DID_$7041</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($708B) Rotor position measure">
<Comment><![CDATA[Vxx_sens_emot_psn]]></Comment>
<Mnemonic>DID_$708B</Mnemonic>
<Bits count="16">
<Scaled DivideBy=" 128"/>
</Bits>
</Data>
<Data Name="($708D) Rotor position measure (for safety monitoring)">
<Comment><![CDATA[Vxx_sens_emot_psn_sfty]]></Comment>
<Mnemonic>DID_$708D</Mnemonic>
<Bits count="16">
<Scaled DivideBy=" 128"/>
</Bits>
</Data>
<Data Name="($7037) Rotor position offset learning + CRC written by diag tool.1">
<Comment><![CDATA[Vxx_emot_psn_ofs_rcp]]></Comment>
<Mnemonic>DID_$7037_1</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="($7037) Rotor position offset learning + CRC written by diag tool.2">
<Comment><![CDATA[Vxx_emot_psn_ofs_crc_rcp]]></Comment>
<Mnemonic>DID_$7037_2</Mnemonic>
<Bytes count="1"/>
</Data>
<Data Name="($7021) Saved resistance rotor.value">
<Comment><![CDATA[Sxx_rot_r_ref + Sxx_rot_r_ref_crc_rcp]]></Comment>
<Mnemonic>DID_$7021_1</Mnemonic>
<Bytes count="2"/>
</Data>
<Data Name="($7021) Saved resistance rotor.CRC">
<Comment><![CDATA[Sxx_rot_r_ref + Sxx_rot_r_ref_crc_rcp]]></Comment>
<Mnemonic>DID_$7021_2</Mnemonic>
<Bytes count="1"/>
</Data>
<Data Name="($709E) SeedBreaker to explain the reset cause">
<Comment><![CDATA[Vxx_invt_rst_ctx_1]]></Comment>
<Mnemonic>DID_$709E</Mnemonic>
<Bits count="16">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($7068) Software overcurrent protection counter for post mortem analysis">
<Comment><![CDATA[Sxx_pm_sw_ocp_invt_ctr]]></Comment>
<Mnemonic>DID_$7068</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($706B) Software overvoltage protection counter for post mortem analysis">
<Comment><![CDATA[Sxx_pm_sw_ovp_ctr]]></Comment>
<Mnemonic>DID_$706B</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($708E) Spare signal for driver board temperature">
<Comment><![CDATA[Vxx_wf_dri_temp]]></Comment>
<Mnemonic>DID_$708E</Mnemonic>
<Bits count="24">
<Scaled Unit="°C" Offset="-20480" DivideBy=" 512"/>
</Bits>
</Data>
<Data Name="($703F) SPI communication default">
<Comment><![CDATA[Wbx_spi_dfl_sfty]]></Comment>
<Mnemonic>DID_$703F</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7089) Stator copper temperature estimation">
<Comment><![CDATA[Vxx_esti_sttr_cu_temp]]></Comment>
<Mnemonic>DID_$7089</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Offset="-5120" DivideBy=" 128"/>
</Bits>
</Data>
<Data Name="($7042) Stator overcurrent validated">
<Comment><![CDATA[Wbx_sw_ocp_invt_mem]]></Comment>
<Mnemonic>DID_$7042</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($7028) status verlog from PEB to EVC">
<Comment><![CDATA[Vbx_eng_run_ena_swlk]]></Comment>
<Mnemonic>DID_$7028</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Vehicle locked"/>
<Item Value="1" Text="Vehicle unlocked"/>
</List>
</Bits>
</Data>
<Data Name="($707D) Supply monitoring default">
<Comment><![CDATA[Vbx_sply_mon]]></Comment>
<Mnemonic>DID_$707D</Mnemonic>
<Bits>
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($704A) TETA CRC received">
<Comment><![CDATA[Vxx_emot_psn_ofs_crc_rcp]]></Comment>
<Mnemonic>DID_$704A</Mnemonic>
<Bytes count="1"/>
</Data>
<Data Name="($703D) The water temperature produced by the Rectifier">
<Comment><![CDATA[Vxx_wtr_temp]]></Comment>
<Mnemonic>DID_$703D</Mnemonic>
<Bits count="7">
<Scaled Unit="°C"/>
</Bits>
</Data>
<Data Name="($70D5) Rotor position sensor safety check">
<Comment><![CDATA[Vbx_emot_psn_chk_sfty]]></Comment>
<Mnemonic>DID_$70D5</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="the 2 positions are inconsisten (difference &gt; thershold)"/>
<Item Value="1" Text="Both positions are consistent (difference &lt;thershold)"/>
</List>
</Bits>
</Data>
<Data Name="($70D6) Rotor Positions Diag">
<Comment><![CDATA[Vsx_dgt_emot_psn_sens_chk_sfty
]]></Comment>
<Mnemonic>DID_$70D6</Mnemonic>
<Bits count="2">
<List>
<Item Value="0" Text="both diag are OK"/>
<Item Value="1" Text="Failure of the functional position acquisitio"/>
<Item Value="2" Text="Failure of the safety position acquisition (sin cos)"/>
<Item Value="3" Text="both diag are NOK"/>
</List>
</Bits>
</Data>
<Data Name="($70D7) HVNetworkVoltage from Battery">
<Comment><![CDATA[Vxx_hv_bat
]]></Comment>
<Mnemonic>DID_$70D7</Mnemonic>
<Bits count="16">
<Scaled Unit="V" Step=" .5"/>
</Bits>
</Data>
<Data Name="($70D8) HVNetworkVoltage from DCDC">
<Comment><![CDATA[Vxx_hv_dcdc]]></Comment>
<Mnemonic>DID_$70D8</Mnemonic>
<Bits count="16">
<Scaled Unit="V" Step=" .5"/>
</Bits>
</Data>
<Data Name="($70E7) Normalized rotor temperature">
<Comment><![CDATA[Vxx_rot_norm_temp
]]></Comment>
<Mnemonic>DID_$70E7
</Mnemonic>
<Bits count="16">
<Scaled Unit="%" Step=" .001953125"/>
</Bits>
</Data>
<Data Name="($70E8) Stator temperature sensor 1 for freeze frame management">
<Comment><![CDATA[Vxx_sttr_temp_1_ffm
]]></Comment>
<Mnemonic>DID_$70E8</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .25" Offset="-40"/>
</Bits>
</Data>
<Data Name="($70E9) Stator temperature sensor 2 for freeze frame management">
<Comment><![CDATA[Vxx_sttr_temp_1_ffm]]></Comment>
<Mnemonic>DID_$70E9</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .25" Offset="-40"/>
</Bits>
</Data>
<Data Name="($70EA) spare signal for driver board temperature for freeze frame management">
<Comment><![CDATA[Vxx_sttr_temp_1_ffm
]]></Comment>
<Mnemonic>DID_$70EA</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .25" Offset="-40"/>
</Bits>
</Data>
<Data Name="($70EB) Excitation temperature for freeze frame management">
<Comment><![CDATA[Vxx_sttr_temp_1_ffm]]></Comment>
<Mnemonic>DID_$70EB</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .25" Offset="-40"/>
</Bits>
</Data>
<Data Name="($70EC) Inverter temperature sensor 1 for freeze frame management">
<Comment><![CDATA[Vxx_sttr_temp_1_ffm]]></Comment>
<Mnemonic>DID_$70EC</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .25" Offset="-40"/>
</Bits>
</Data>
<Data Name="($70ED) MICRO temperature for freeze frame management">
<Comment><![CDATA[Vxx_sttr_temp_1_ffm]]></Comment>
<Mnemonic>DID_$70ED</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .25" Offset="-40"/>
</Bits>
</Data>
<Data Name="($70EE)PCB temperature for freeze frame management">
<Comment><![CDATA[Vxx_sttr_temp_1_ffm]]></Comment>
<Mnemonic>DID_$70EE</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .25" Offset="-40"/>
</Bits>
</Data>
<Data Name="($70F0) Absolute time since first Ignition">
<Comment><![CDATA[Vxx_t_abs_igk_1]]></Comment>
<Mnemonic>DID_$70F0</Mnemonic>
<Bits count="16">
<Scaled Unit="min"/>
</Bits>
</Data>
<Data Name="($70F2) Environment temperature">
<Comment><![CDATA[Vxx_air_tenv]]></Comment>
<Mnemonic>DID_$70F2</Mnemonic>
<Bits count="16">
<Scaled Unit="°C" Step=" .0078125" Offset="-40"/>
</Bits>
</Data>
<Data Name="($7016)Result of the check on CAN with EVC (torque request CLK+torque request CRC+CAN confirmed absent)">
<Comment><![CDATA[Vbx_can_emot_tq_sp_nok]]></Comment>
<Mnemonic>DID_$7016</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="Check is Ok"/>
<Item Value="1" Text="Check is Nok"/>
</List>
</Bits>
</Data>
<Data Name="($70CB)Nvrol error counters.8 bits MSB(double bit errors number).8 bits LSB(simple bit errors number)">
<Comment><![CDATA[Vxx_inv_nvrol_err_cnt]]></Comment>
<Mnemonic>DID_$70CB</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($70EF) counter giving the nember of times Wsx_cuc_f_dfl is equal to Nsx_i_f_df">
<Comment><![CDATA[Sxx_cuc_f_dfl_3_ctr]]></Comment>
<Mnemonic>DID_$70EF</Mnemonic>
<Bits count="16">
<Scaled/>
</Bits>
</Data>
<Data Name="($70F1) Max ratio between the square of excitation sgnl and the sum of squares of rotor reslver cos and sin sgnl">
<Comment><![CDATA[Vxx_emot_psn_sq_rat_max]]></Comment>
<Mnemonic>DID_$70F1</Mnemonic>
<Bits count="16">
<Scaled Step=" .001953125"/>
</Bits>
</Data>
<Data Name="Ratio between square of excitation signal and sum of squares of rotor reslver cos and sine signals">
<Comment><![CDATA[Vxx_emot_psn_sq_rat]]></Comment>
<Mnemonic>DID_$70F3</Mnemonic>
<Bits count="16">
<Scaled Step=" .001953125"/>
</Bits>
</Data>
<Data Name="($2000) DIDs supported in range [$2001 - $2020]">
<Comment><![CDATA[DIDs supported in range [$2001 - $2020]]]></Comment>
<Mnemonic>DID_$2000</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($2060) DIDs supported in range [$2061 - $2080]">
<Comment><![CDATA[DIDs supported in range [$2061 - $2080]]]></Comment>
<Mnemonic>DID_$2060</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($7000) DIDs supported in range [$7001 - $7020]">
<Comment><![CDATA[DIDs supported in range [$7001 - $7020]]]></Comment>
<Mnemonic>DID_$7000</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($7020) DIDs supported in range [$7021 - $7040]">
<Comment><![CDATA[DIDs supported in range [$7021 - $7040]]]></Comment>
<Mnemonic>DID_$7020</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($7040) DIDs supported in range [$7041 - $7060]">
<Comment><![CDATA[DIDs supported in range [$7041 - $7060]]]></Comment>
<Mnemonic>DID_$7040</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($7060) DIDs supported in range [$7061 - $7080]">
<Comment><![CDATA[DIDs supported in range [$7061 - $7080]]]></Comment>
<Mnemonic>DID_$7060</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($7080) DIDs supported in range [$7081 - $70A0]">
<Comment><![CDATA[DIDs supported in range [$7081 - $70A0]]]></Comment>
<Mnemonic>DID_$7080</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($70A0) DIDs supported in range [$70A1 - $70C0]">
<Comment><![CDATA[DIDs supported in range [$70A1 - $70C0]]]></Comment>
<Mnemonic>DID_$70A0</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($70C0) DIDs supported in range [$70C1 - $70E0]">
<Comment><![CDATA[DIDs supported in range [$70C1 - $70E0]]]></Comment>
<Mnemonic>DID_$70C0</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vtx_TaskMaxDurationIT_A[3]_(bit8-11)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.07</Mnemonic>
<Bits count="4">
<Scaled Unit="ms" Format="bin"/>
</Bits>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Stack Overflow on State_(bit6-7)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.06</Mnemonic>
<Bits count="2">
<List>
<Item Value="0" Text="No overflow"/>
<Item Value="1" Text="overflow on Istack"/>
<Item Value="2" Text="overflow on Ustack"/>
<Item Value="3" Text="overflowon Csa"/>
</List>
</Bits>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vxx_10ms_max_duration_(bit12-15)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.08</Mnemonic>
<Bits count="4">
<Scaled Unit="ms" Format="bin"/>
</Bits>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_sply_mon_(bit5)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.05</Mnemonic>
<Bits count="1">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_alim_21_mon_(bit3)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.03</Mnemonic>
<Bits count="1">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_alim_21_mon_red_(bit4)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.04</Mnemonic>
<Bits count="1">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_dfl_i_f_low_(bit2)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.02</Mnemonic>
<Bits count="1">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vsx_emot_n_dfl_sfty_(bit1)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.01</Mnemonic>
<Bits count="1">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_rot_temp_dfl_sfty_(bit0)">
<Comment><![CDATA[Vxx_invt_rst_ctx_4]]></Comment>
<Mnemonic>DID_$70A2.00</Mnemonic>
<Bits count="1">
<Scaled Format="bin"/>
</Bits>
</Data>
<Data Name="($70E0) DIDs supported in range [$70E1 - $7100]">
<Comment><![CDATA[DIDs supported in range [$70E1 - $7100]]]></Comment>
<Mnemonic>DID_$70E0</Mnemonic>
<Bytes count="4"/>
</Data>
<Data Name="($702A) software over voltage protection">
<Comment><![CDATA[Vbx_sw_ovp_udc_mem]]></Comment>
<Mnemonic>DID_$702A</Mnemonic>
<Bits count="1">
<List>
<Item Value="0" Text="No default"/>
<Item Value="1" Text="Default"/>
</List>
</Bits>
</Data>
<Data Name="($702C) Distribution type from JB to PEB">
<Comment><![CDATA[Vsx_chg_dstb_req]]></Comment>
<Mnemonic>DID_$702C</Mnemonic>
<Bits count="2">
<List>
<Item Value="0" Text="not used"/>
<Item Value="1" Text="Default (Nsx_jb_chg_dstb_dft)"/>
<Item Value="2" Text="Simultaneous (Nsx_jb_chg_dstb_smlt)"/>
<Item Value="3" Text="Lag (Nsx_jb_chg_dstb_lag)"/>
</List>
</Bits>
</Data>
<Data Name="($7090) Water temperature">
<Comment><![CDATA[Wxx_wtr_temp]]></Comment>
<Mnemonic>DID_$7090</Mnemonic>
<Bits count="7">
<Scaled Unit="°C"/>
</Bits>
</Data>
<Data Name="DTCMileageLastOccurence">
<Comment><![CDATA[Distance Totalizer of the vehicle]]></Comment>
<Mnemonic>DID_$F0D0</Mnemonic>
<Bits count="24">
<Scaled Unit="km"/>
</Bits>
</Data>
<Data Name="VehicleManufacturerECUHardwareNumber_DAI">
<Comment><![CDATA[Vxx_db_hw_nr_1]]></Comment>
<Mnemonic>DID_$F111</Mnemonic>
<Bytes count="10" ascii="1"/>
</Data>
<Data Name="VehicleManufacturerECUSoftwareNumber_DAI">
<Comment><![CDATA[Vxx_db_sw_nr_0_1]]></Comment>
<Mnemonic>DID_$F121</Mnemonic>
<Bytes count="20" ascii="1"/>
</Data>
</Datas>
<Requests Endian="Big">
<Request Name="StartDiagnosticSession.Default">
<DossierMaintenabilite/>
<Comment><![CDATA[Standard definition for DDT2000 automatic screen]]></Comment>
<Sent>
<SentBytes>1081</SentBytes>
</Sent>
<Received MinBytes="2">
<ReplyBytes>5081</ReplyBytes>
</Received>
</Request>
<Request Name="StartDiagnosticSession.Programming">
<DossierMaintenabilite/>
<Comment><![CDATA[Standard definition for DDT2000 automatic screen]]></Comment>
<Sent>
<SentBytes>1085</SentBytes>
</Sent>
<Received MinBytes="2">
<ReplyBytes>5085</ReplyBytes>
</Received>
</Request>
<Request Name="ClearDiagnosticInformation.All">
<DossierMaintenabilite/>
<Comment><![CDATA[The ClearDiagnosticInformation service is used by the tool to clear diagnostic information in an ECUs memory]]></Comment>
<Sent>
<SentBytes>14FFFFFF</SentBytes>
</Sent>
<Received MinBytes="1">
<ReplyBytes>54</ReplyBytes>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportDTC">
<DossierMaintenabilite/>
<Comment><![CDATA[DDT2000 Failures page requests / Clip import : Unusable in the standard tools of DDT2000]]></Comment>
<Sent>
<SentBytes>1902AF</SentBytes>
</Sent>
<Received MinBytes="3">
<ShiftBytesCount>4</ShiftBytesCount>
<ReplyBytes>59020000000000</ReplyBytes>
<DataItem Name="StatusOfDTC" FirstByte="7"/>
<DataItem Name="DTCStatus.testFailed" FirstByte="7" BitOffset="7"/>
<DataItem Name="DTCStatus.testFailedThisMonitoringCycle" FirstByte="7" BitOffset="6"/>
<DataItem Name="DTCStatus.pendingDTC" FirstByte="7" BitOffset="5"/>
<DataItem Name="DTCStatus.confirmedDTC" FirstByte="7" BitOffset="4"/>
<DataItem Name="DTCStatus.testNotCompletedSinceLastClear" FirstByte="7" BitOffset="3"/>
<DataItem Name="DTCStatus.testFailedSinceLastClear" FirstByte="7" BitOffset="2"/>
<DataItem Name="DTCStatus.testNotCompletedThisMonitoringCycle" FirstByte="7" BitOffset="1"/>
<DataItem Name="DTCStatus.warningIndicatorRequested" FirstByte="7"/>
<DataItem Name="DTCFailureType.Category" FirstByte="6"/>
<DataItem Name="DTCFailureType" FirstByte="6"/>
<DataItem Name="DTCDeviceIdentifier" FirstByte="4"/>
<DataItem Name="DTCDeviceAndFailureTypeOBD" FirstByte="4"/>
<DataItem Name="DTCFailureType.ManufacturerOrSupplier" FirstByte="6" BitOffset="4"/>
<DataItem Name="DTCStatusAvailabilityMask" FirstByte="3"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportSnapshot">
<DossierMaintenabilite/>
<Comment><![CDATA[DDT2000 Failures page requests / Clip import : Unusable in the standard tools of DDT2000]]></Comment>
<Sent>
<SentBytes>1904000000FF</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="6">
<ReplyBytes>590400000000</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportExtendedData.AgingCounter">
<DossierMaintenabilite/>
<Comment><![CDATA[Request for the import in the Clip]]></Comment>
<Sent>
<SentBytes>190600000081</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="8">
<ReplyBytes>5906000000008100</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
<DataItem Name="DTCExtendedData.AgingCounter" FirstByte="8"/>
<DataItem Name="DTCExtendedDataRecordNumber" FirstByte="7"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportExtendedData.DTCOccurrenceCounter">
<DossierMaintenabilite/>
<Comment><![CDATA[Request for the import in the Clip]]></Comment>
<Sent>
<SentBytes>190600000082</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="8">
<ReplyBytes>5906000000008200</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
<DataItem Name="DTCExtendedData.DTCOccurrenceCounter" FirstByte="8"/>
<DataItem Name="DTCExtendedDataRecordNumber" FirstByte="7"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportExtendedData.DTCOccurrenceCounter_2">
<DossierMaintenabilite/>
<Comment><![CDATA[Request for the import in the Clip]]></Comment>
<Sent>
<SentBytes>190600000084</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="8">
<ReplyBytes>5906000000008400</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
<DataItem Name="DTCExtendedData.DTCOccurrenceCounter_2" FirstByte="8"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportExtendedData.DTCLastDiseappearMileage">
<DossierMaintenabilite/>
<Comment><![CDATA[Request for the import in the Clip]]></Comment>
<Sent>
<SentBytes>190600000085</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="10">
<ReplyBytes>59060000000085000000</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
<DataItem Name="DTCExtendedData.DTCLastDiseappearMileage" FirstByte="8"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportExtendedData.DTCTravelledDistanceFailureType">
<DossierMaintenabilite/>
<Comment><![CDATA[Request for the import in the Clip]]></Comment>
<Sent>
<SentBytes>190600000086</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="10">
<ReplyBytes>59060000000086000000</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
<DataItem Name="DTCExtendedData.DTCTravelledDistanceFailurePresent" FirstByte="8"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportExtendedData.DTCFirstAppearMileage">
<DossierMaintenabilite/>
<Comment><![CDATA[Request for the import in the Clip]]></Comment>
<Sent>
<SentBytes>190600000087</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="10">
<ReplyBytes>59060000000087000000</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
<DataItem Name="DTCExtendedData.DTCFirstAppearMileage" FirstByte="8"/>
</Received>
</Request>
<Request Name="DataRead.Identification.RenaultR2">
<DossierMaintenabilite/>
<Comment><![CDATA[ReadDataByLocalIdentifier : Use this request if ECU use Coding Renault R2 or 5DIGITS]]></Comment>
<Sent>
<SentBytes>2180</SentBytes>
</Sent>
<Received MinBytes="26">
<ReplyBytes>6180000000000000000000000000000000000000000000000000</ReplyBytes>
<DataItem Name="CalibrationNumber" Ref="1" FirstByte="21"/>
<DataItem Name="DiagnosticIdentificationCode" Ref="1" FirstByte="8"/>
<DataItem Name="SoftwareNumber" Ref="1" FirstByte="17"/>
<DataItem Name="SupplierNumber.ITG" Ref="1" FirstByte="9"/>
<DataItem Name="EditionNumber" Ref="1" FirstByte="19"/>
<DataItem Name="PartNumber.BasicPartList" Ref="1" FirstByte="23"/>
<DataItem Name="HardwareNumber.BasicPartList" Ref="1" FirstByte="24"/>
<DataItem Name="ApprovalNumber.BasicPartList" Ref="1" FirstByte="25"/>
<DataItem Name="PartNumber.LowerPart" Ref="1" FirstByte="3"/>
<DataItem Name="HardwareNumber.LowerPart" Ref="1" FirstByte="12"/>
<DataItem Name="ManufacturerIdentificationCode" Ref="1" FirstByte="26"/>
</Received>
</Request>
<Request Name="DataRead.History.Ident.0">
<DossierMaintenabilite/>
<DenyAccess>
<NoSDS/>
</DenyAccess>
<Comment><![CDATA[ReadDataByLocalIdentifier]]></Comment>
<Sent>
<SentBytes>21F0</SentBytes>
</Sent>
<Received MinBytes="26">
<ReplyBytes>61F0000000000000000000000000000000000000000000000000</ReplyBytes>
<DataItem Name="CalibrationNumber" FirstByte="21"/>
<DataItem Name="DiagnosticIdentificationCode" FirstByte="8"/>
<DataItem Name="SoftwareNumber" FirstByte="17"/>
<DataItem Name="SupplierNumber.ITG" FirstByte="9"/>
<DataItem Name="EditionNumber" FirstByte="19"/>
<DataItem Name="PartNumber.BasicPartList" FirstByte="23"/>
<DataItem Name="HardwareNumber.BasicPartList" FirstByte="24"/>
<DataItem Name="ApprovalNumber.BasicPartList" FirstByte="25"/>
<DataItem Name="PartNumber.LowerPart" FirstByte="3"/>
<DataItem Name="HardwareNumber.LowerPart" FirstByte="12"/>
<DataItem Name="ManufacturerIdentificationCode" FirstByte="26"/>
</Received>
</Request>
<Request Name="DataRead.History.Reprog.0">
<DossierMaintenabilite/>
<DenyAccess>
<NoSDS/>
</DenyAccess>
<Comment><![CDATA[ReadDataByLocalIdentifier]]></Comment>
<Sent>
<SentBytes>21F1</SentBytes>
</Sent>
<Received MinBytes="26">
<ReplyBytes>61F100000000000000000000000000000000000000000000000000</ReplyBytes>
<DataItem Name="ApprovalNumber.LowerPart" FirstByte="3"/>
<DataItem Name="ProgrammingSiteReference" FirstByte="8"/>
<DataItem Name="ProgrammingToolReference" FirstByte="13"/>
<DataItem Name="NumberOfReprogrammings" FirstByte="18"/>
<DataItem Name="DateOfReprogramming" FirstByte="19"/>
<DataItem Name="SaveMarking" FirstByte="24"/>
<DataItem Name="CrcOfLogSave" FirstByte="25"/>
<DataItem Name="TimeOfReprogramming" FirstByte="22"/>
</Received>
</Request>
<Request Name="FailuresDetect.All">
<DossierMaintenabilite/>
<Comment><![CDATA[DDT2000 Failures page requests / Clip import (Conditional)]]></Comment>
<Sent>
<SentBytes>310100</SentBytes>
<DataItem Name="RoutineEntryOption" FirstByte="3"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>710100</ReplyBytes>
<DataItem Name="RoutineEntryStatus" FirstByte="3"/>
</Received>
</Request>
<Request Name="TesterPresent.WithResponse">
<DossierMaintenabilite/>
<Comment><![CDATA[This request enable P2P tester present for tool (Screen, IOctl, ...)]]></Comment>
<Sent>
<SentBytes>3E01</SentBytes>
</Sent>
<Received MinBytes="1">
<ReplyBytes>7E</ReplyBytes>
</Received>
</Request>
<Request Name="Output Control">
<DossierMaintenabilite/>
<DenyAccess>
<NoSDS/>
</DenyAccess>
<Comment><![CDATA[Standard DDT2000 Request 'Output Control']]></Comment>
<Sent>
<SentBytes>300000</SentBytes>
<DataItem Name="Output Temporary Control List" FirstByte="2"/>
<DataItem Name="Output Control Command" FirstByte="3"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>700000</ReplyBytes>
<DataItem Name="Output Temporary Control List-answer" FirstByte="2"/>
<DataItem Name="Output Control Status" FirstByte="3"/>
</Received>
</Request>
<Request Name="StartRoutineByLocalIdentifier">
<DossierMaintenabilite/>
<ManuelSend/>
<DenyAccess>
<NoSDS/>
</DenyAccess>
<Comment><![CDATA[StartRoutineByLocalIdentifier]]></Comment>
<Sent>
<SentBytes>310000</SentBytes>
<DataItem Name="RoutineLocalIdentifierStart" FirstByte="2"/>
<DataItem Name="RoutineEntryOption" FirstByte="3"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>710000</ReplyBytes>
<DataItem Name="RoutineLocalIdentifierStart-answer" FirstByte="2"/>
<DataItem Name="RoutineEntryStatus" FirstByte="3"/>
</Received>
</Request>
<Request Name="StopRoutineByLocalIdentifier">
<DossierMaintenabilite/>
<ManuelSend/>
<DenyAccess>
<NoSDS/>
</DenyAccess>
<Comment><![CDATA[StoproutineByLocalIdentifier]]></Comment>
<Sent>
<SentBytes>320000</SentBytes>
<DataItem Name="RoutineExitOption" FirstByte="3"/>
<DataItem Name="RoutineLocalIdentifierStop" FirstByte="2"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>720000</ReplyBytes>
<DataItem Name="RoutineExitStatus" FirstByte="3"/>
<DataItem Name="RoutineLocalIdentifierStop-answer" FirstByte="2"/>
</Received>
</Request>
<Request Name="Frame Traceability Information">
<DossierMaintenabilite/>
<Comment><![CDATA[ReadDataByLocalIdentifier]]></Comment>
<Sent>
<SentBytes>2184</SentBytes>
</Sent>
<Received MinBytes="22">
<ReplyBytes>61840000000000000000000000000000000000000000</ReplyBytes>
<DataItem Name="ITG Supplier Number" Ref="1" FirstByte="3"/>
<DataItem Name="Traceability Factory Code" Ref="1" FirstByte="6"/>
<DataItem Name="Traceability Serial Number" Ref="1" FirstByte="7"/>
</Received>
</Request>
<Request Name="Read Frame VIN">
<DossierMaintenabilite/>
<Comment><![CDATA[ReadDataByLocalIdentifier]]></Comment>
<Sent>
<SentBytes>2181</SentBytes>
</Sent>
<Received MinBytes="21">
<ReplyBytes>618100000000000000000000000000000000000000</ReplyBytes>
<DataItem Name="CRC" Ref="1" FirstByte="20"/>
<DataItem Name="V.I.N" Ref="1" FirstByte="3"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportExtendedData.Mileage">
<DossierMaintenabilite/>
<Comment><![CDATA[Request for the import in the Clip]]></Comment>
<Sent>
<SentBytes>190600000080</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="10">
<ReplyBytes>59060000000080000000</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
<DataItem Name="DTCExtendedData.Mileage" FirstByte="8"/>
<DataItem Name="DTCExtendedDataRecordNumber" FirstByte="7" Endian="Little"/>
</Received>
</Request>
<Request Name="ReadDTCInformation.ReportExtendedData">
<DossierMaintenabilite/>
<Comment><![CDATA[DDT2000 Failures page requests : Unusable in the standard tools of DDT2000]]></Comment>
<Sent>
<SentBytes>1906000000FF</SentBytes>
<DataItem Name="DTCMaskRecord" FirstByte="3"/>
</Sent>
<Received MinBytes="6">
<ReplyBytes>590600000000</ReplyBytes>
<DataItem Name="DTCRecord" FirstByte="3"/>
<DataItem Name="StatusOfDTC" FirstByte="6"/>
<DataItem Name="DTCExtendedData.DTCOccurrenceCounter_2" FirstByte="8"/>
<DataItem Name="DTCExtendedData.Mileage" FirstByte="8"/>
<DataItem Name="DTCExtendedDataRecordNumber" FirstByte="7"/>
<DataItem Name="DTCExtendedData.DTCFirstAppearMileage" FirstByte="8"/>
<DataItem Name="DTCExtendedData.DTCLastDiseappearMileage" FirstByte="8"/>
<DataItem Name="DTCExtendedData.DTCTravelledDistanceFailurePresent" FirstByte="8"/>
<DataItem Name="DTCExtendedData.AgingCounter" FirstByte="8"/>
<DataItem Name="DTCExtendedData.DTCOccurrenceCounter" FirstByte="8"/>
</Received>
</Request>
<Request Name="Configuration of Electrical Vehicle Networks">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Service de lecture de la configuration du réseau CAN]]></Comment>
<Sent>
<SentBytes>21B7</SentBytes>
</Sent>
<Received MinBytes="13">
<ReplyBytes>61B7</ReplyBytes>
<DataItem Name="Configuration of Electrical Vehicle Networks" Ref="1" FirstByte="3"/>
</Received>
</Request>
<Request Name="List of Electrical Vehicle ECUs with After-sales diagnostic">
<DossierMaintenabilite/>
<ManuelSend/>
<Sent>
<SentBytes>21B8</SentBytes>
</Sent>
<Received MinBytes="13">
<ReplyBytes>61B8</ReplyBytes>
<DataItem Name="List of Electrical Vehicle ECUs with After-sales diagnostic" Ref="1" FirstByte="3"/>
</Received>
</Request>
<Request Name="DataWrite.Configuration_of_Electrical_Vehicle_Networks">
<Sent>
<SentBytes>3BB70000000000000000000000</SentBytes>
<DataItem Name="Configuration of Electrical Vehicle Networks" FirstByte="3"/>
</Sent>
<Received MinBytes="2">
<ReplyBytes>7BB7</ReplyBytes>
</Received>
</Request>
<Request Name="DataWrite.List of Electrical Vehicle ECUs with After-sales diagnostic">
<Sent>
<SentBytes>3BB80000000000000000000000</SentBytes>
<DataItem Name="List of Electrical Vehicle ECUs with After-sales diagnostic" FirstByte="3"/>
</Sent>
<Received MinBytes="2">
<ReplyBytes>7BB8</ReplyBytes>
</Received>
</Request>
<Request Name="StartDiagnosticSession.ExtendedDiagnosticSession">
<DossierMaintenabilite/>
<Comment><![CDATA[Standard definition for DDT2000 automatic screen]]></Comment>
<Sent>
<SentBytes>10C0</SentBytes>
</Sent>
<Received MinBytes="2">
<ReplyBytes>50C0</ReplyBytes>
</Received>
</Request>
<Request Name="StartRoutineByLocalIdentifier - Factory Static Test">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $31 - StartRoutineByLocalIdentifier - Factory Static test]]></Comment>
<Sent>
<SentBytes>310700</SentBytes>
</Sent>
<Received MinBytes="3">
<ReplyBytes>710700</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.Daimler system identification">
<DossierMaintenabilite/>
<Comment><![CDATA[ReadDataByLocalIdentifier - Daimler system identification]]></Comment>
<Sent>
<SentBytes>21EF</SentBytes>
</Sent>
<Received MinBytes="22">
<ReplyBytes>61EF0000000000000000000000000000000000000000</ReplyBytes>
<DataItem Name="Hardware Part Number 1" Ref="1" FirstByte="3"/>
<DataItem Name="Hardware Part Number 2" Ref="1" FirstByte="4"/>
<DataItem Name="Hardware Part Number 3" Ref="1" FirstByte="5"/>
<DataItem Name="Hardware Part Number 4" Ref="1" FirstByte="6"/>
<DataItem Name="Hardware Part Number 5" Ref="1" FirstByte="7"/>
<DataItem Name="Hardware Part Number 6" Ref="1" FirstByte="8"/>
<DataItem Name="Hardware Part Number 7" Ref="1" FirstByte="9"/>
<DataItem Name="Hardware Part Number 8" Ref="1" FirstByte="10"/>
<DataItem Name="Hardware Part Number 9" Ref="1" FirstByte="11"/>
<DataItem Name="Hardware Part Number 10" Ref="1" FirstByte="12"/>
<DataItem Name="Software Part Number 1" Ref="1" FirstByte="13"/>
<DataItem Name="Software Part Number 2" Ref="1" FirstByte="14"/>
<DataItem Name="Software Part Number 3" Ref="1" FirstByte="15"/>
<DataItem Name="Software Part Number 4" Ref="1" FirstByte="16"/>
<DataItem Name="Software Part Number 5" Ref="1" FirstByte="17"/>
<DataItem Name="Software Part Number 6" Ref="1" FirstByte="18"/>
<DataItem Name="Software Part Number 7" Ref="1" FirstByte="19"/>
<DataItem Name="Software Part Number 8" Ref="1" FirstByte="20"/>
<DataItem Name="Software Part Number 9" Ref="1" FirstByte="21"/>
<DataItem Name="Software Part Number 10" Ref="1" FirstByte="22"/>
</Received>
</Request>
<Request Name="DataWrite.Vehicle_Identification_Number">
<DossierMaintenabilite/>
<ManuelSend/>
<Sent>
<SentBytes>3B8100000000000000000000000000000000000000</SentBytes>
<DataItem Name="Vin In Ascii" FirstByte="3"/>
<DataItem Name="Vin CRC" FirstByte="20"/>
</Sent>
<Received MinBytes="2">
<ReplyBytes>7B81</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($2001) Rotor mechanical rotation speed">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_emot_n]]></Comment>
<Sent>
<SentBytes>222001</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6220010000</ReplyBytes>
<DataItem Name="($2001) Rotor mechanical rotation speed" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2002) Emotor torque estimation, based on measured current values">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_esti_emot_tq]]></Comment>
<Sent>
<SentBytes>222002</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6220020000</ReplyBytes>
<DataItem Name="($2002) Emotor torque estimation, based on measured current values" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2003) Torque setpoint from EVC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_emot_tq_sp]]></Comment>
<Sent>
<SentBytes>222003</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6220030000</ReplyBytes>
<DataItem Name="($2003) Torque setpoint from EVC" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2004) Battery voltage sensor">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_udc]]></Comment>
<Sent>
<SentBytes>222004</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6220040000</ReplyBytes>
<DataItem Name="($2004) Battery voltage sensor" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2005) DCDC output tension measure">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_dcdc_volt_ou_mes_raw]]></Comment>
<Sent>
<SentBytes>222005</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6220050000</ReplyBytes>
<DataItem Name="($2005) DCDC output tension measure" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2070) Immobilizer - diagnosis availability">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_swlk_diag_avl]]></Comment>
<Sent>
<SentBytes>222070</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62207000</ReplyBytes>
<DataItem Name="($2070) Immobilizer - diagnosis availability" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($2071) Immobilizer - Byte 1 used to allow diagnosis">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_swlk_diag_1]]></Comment>
<Sent>
<SentBytes>222071</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62207100</ReplyBytes>
<DataItem Name="($2071) Immobilizer - Byte 1 used to allow diagnosis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2072) Immobilizer - Byte 2 used to allow diagnosis">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_swlk_diag_2]]></Comment>
<Sent>
<SentBytes>222072</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62207200</ReplyBytes>
<DataItem Name="($2072) Immobilizer - Byte 2 used to allow diagnosis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2073) Immobilizer - Byte 3 used to allow diagnosis">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_swlk_diag_3]]></Comment>
<Sent>
<SentBytes>222073</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62207300</ReplyBytes>
<DataItem Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.0" Ref="1" FirstByte="4" BitOffset="7"/>
<DataItem Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.1" Ref="1" FirstByte="4" BitOffset="6"/>
<DataItem Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.2" Ref="1" FirstByte="4" BitOffset="5"/>
<DataItem Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.3" Ref="1" FirstByte="4" BitOffset="4"/>
<DataItem Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.4" Ref="1" FirstByte="4" BitOffset="2"/>
<DataItem Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.6" Ref="1" FirstByte="4" BitOffset="1"/>
<DataItem Name="($2073) Immobilizer - Byte 3 used to allow diagnosis.7" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2074) Immobilizer - engine not running due to ECM">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_swlk_diag_ecm]]></Comment>
<Sent>
<SentBytes>222074</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62207400</ReplyBytes>
<DataItem Name="($2074) Immobilizer - engine not running due to ECM" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($2075) Immobilizer - engine not running due to BCM in secure mode">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_swlk_diag_tool]]></Comment>
<Sent>
<SentBytes>222075</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62207500</ReplyBytes>
<DataItem Name="($2075) Immobilizer - engine not running due to BCM in secure mode" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($2076) Immobilizer - engine not running due to no BCM authorization">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_swlk_diag_ccu]]></Comment>
<Sent>
<SentBytes>222076</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62207600</ReplyBytes>
<DataItem Name="($2076) Immobilizer - engine not running due to no BCM authorization" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($2077) Immobilizer - engine not running due to a CAN network problem with the BCM">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_swlk_diag_mux]]></Comment>
<Sent>
<SentBytes>222077</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62207700</ReplyBytes>
<DataItem Name="($2077) Immobilizer - engine not running due to a CAN network problem with the BCM" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7001) Command of PEC fan">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_cfa_pwm_sp]]></Comment>
<Sent>
<SentBytes>227001</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62700100</ReplyBytes>
<DataItem Name="($7001) Command of PEC fan" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7002) Wired APC signal">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_dcdc_apc_raw]]></Comment>
<Sent>
<SentBytes>227002</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62700200</ReplyBytes>
<DataItem Name="($7002) Wired APC signal" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7003) Measured rotor current (sensor 1)">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_i_f_1]]></Comment>
<Sent>
<SentBytes>227003</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270030000</ReplyBytes>
<DataItem Name="($7003) Measured rotor current (sensor 1)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7004) Measured rotor current (sensor 2)">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_i_f_2]]></Comment>
<Sent>
<SentBytes>227004</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270040000</ReplyBytes>
<DataItem Name="($7004) Measured rotor current (sensor 2)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7005) Verlog Status">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_eng_run_ena_swlk]]></Comment>
<Sent>
<SentBytes>227005</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62700500</ReplyBytes>
<DataItem Name="($7005) Verlog Status" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7006) Wire frame APC state">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_wf_apc]]></Comment>
<Sent>
<SentBytes>227006</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62700600</ReplyBytes>
<DataItem Name="($7006) Wire frame APC state" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7007) Measured stator current on phase U">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_i_mot_ph_1]]></Comment>
<Sent>
<SentBytes>227007</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270070000</ReplyBytes>
<DataItem Name="($7007) Measured stator current on phase U" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7008) Measured stator current on phase V">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_i_mot_ph_2]]></Comment>
<Sent>
<SentBytes>227008</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270080000</ReplyBytes>
<DataItem Name="($7008) Measured stator current on phase V" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7009) Measured stator current on phase W">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_i_mot_ph_3]]></Comment>
<Sent>
<SentBytes>227009</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270090000</ReplyBytes>
<DataItem Name="($7009) Measured stator current on phase W" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($700A) Feedback fan raw diagnostic">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_raw_cfa_nok]]></Comment>
<Sent>
<SentBytes>22700A</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62700A00</ReplyBytes>
<DataItem Name="($700A) Feedback fan raw diagnostic" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($700B) Excitation temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_wf_exct_temp]]></Comment>
<Sent>
<SentBytes>22700B</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62700B000000</ReplyBytes>
<DataItem Name="($700B) Excitation temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($700C) Inverter temperature sensor 1">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_wf_invt_temp_1]]></Comment>
<Sent>
<SentBytes>22700C</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62700C000000</ReplyBytes>
<DataItem Name="($700C) Inverter temperature sensor 1" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($700D) MICRO temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_wf_mc_temp]]></Comment>
<Sent>
<SentBytes>22700D</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62700D000000</ReplyBytes>
<DataItem Name="($700D) MICRO temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($700E) PCB temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_wf_pcb_temp]]></Comment>
<Sent>
<SentBytes>22700E</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62700E000000</ReplyBytes>
<DataItem Name="($700E) PCB temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($700F) Stator temperature sensor 1">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_sttr_temp_1]]></Comment>
<Sent>
<SentBytes>22700F</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62700F000000</ReplyBytes>
<DataItem Name="($700F) Stator temperature sensor 1" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7010) Stator temperature sensor 2">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_sttr_temp_2]]></Comment>
<Sent>
<SentBytes>227010</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627010000000</ReplyBytes>
<DataItem Name="($7010) Stator temperature sensor 2" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7011) Raw rotor position resolver angular position measurement">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_sens_emot_psn_raw]]></Comment>
<Sent>
<SentBytes>227011</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270110000</ReplyBytes>
<DataItem Name="($7011) Raw rotor position resolver angular position measurement" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7012) Status flag of the Smartcoder">
<DossierMaintenabilite/>
<Comment><![CDATA[Reaquest $22 - Wxx_sens_emot_psn_sf]]></Comment>
<Sent>
<SentBytes>227012</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62701200</ReplyBytes>
<DataItem Name="($7012) Status flag of the Smartcoder" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7013) Raw rotor position resolver cosine voltage">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_sens_emot_psn_raw_cos_0]]></Comment>
<Sent>
<SentBytes>227013</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270130000</ReplyBytes>
<DataItem Name="($7013) Raw rotor position resolver cosine voltage" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7014) Raw rotor position resolver cosine voltage with 25µs delay">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_sens_emot_psn_raw_cos_25]]></Comment>
<Sent>
<SentBytes>227014</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270140000</ReplyBytes>
<DataItem Name="($7014) Raw rotor position resolver cosine voltage with 25µs delay" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7015) Raw rotor position resolver excitation peak voltage">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_sens_emot_psn_raw_exc]]></Comment>
<Sent>
<SentBytes>227015</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270150000</ReplyBytes>
<DataItem Name="($7015) Raw rotor position resolver excitation peak voltage" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7017) Failure vector allowing exact identification of the failure.1">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_dcdc_diag_1]]></Comment>
<Sent>
<SentBytes>227017</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270170000</ReplyBytes>
<DataItem Name="($7017) Failure vector allowing exact identification of the failure.1" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7018) Failure vector allowing exact identification of the failure.2">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_dcdc_diag_2]]></Comment>
<Sent>
<SentBytes>227018</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62701800</ReplyBytes>
<DataItem Name="($7018) Failure vector allowing exact identification of the failure.2" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7019) Failure vector allowing exact identification of the failure.3">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_dcdc_diag_3]]></Comment>
<Sent>
<SentBytes>227019</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62701900</ReplyBytes>
<DataItem Name="($7019) Failure vector allowing exact identification of the failure.3" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($701A) Failure vector allowing exact identification of the failure.4">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_dcdc_diag_4]]></Comment>
<Sent>
<SentBytes>22701A</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62701A0000</ReplyBytes>
<DataItem Name="($701A) Failure vector allowing exact identification of the failure.4" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($701B) Failure vector allowing exact identification of the DCDC event">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_dcdc_diag_5]]></Comment>
<Sent>
<SentBytes>22701B</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62701B00</ReplyBytes>
<DataItem Name="($701B) Failure vector allowing exact identification of the DCDC event" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($701C) Saved rotor position offset">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Sxx_emot_psn_ofs]]></Comment>
<Sent>
<SentBytes>22701C</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62701C000000</ReplyBytes>
<DataItem Name="($701C) Saved rotor position offset.value" Ref="1" FirstByte="4"/>
<DataItem Name="($701C) Saved rotor position offset.CRC" Ref="1" FirstByte="6"/>
<DataItem Name="($701C) Saved rotor position offset.value.physical" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($701D) Counter of FAN fail times to cool the machine stator in hard conditions.1">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Sxx_fan_nok_fail_1]]></Comment>
<Sent>
<SentBytes>22701D</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62701D0000</ReplyBytes>
<DataItem Name="($701D) Counter of FAN fail times to cool the machine stator in hard conditions.1" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($701D) Counter of FAN fail times to cool the machine stator in hard conditions.1">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Sxx_fan_nok_fail_1]]></Comment>
<Sent>
<SentBytes>2E701D0000</SentBytes>
<DataItem Name="($701D) Counter of FAN fail times to cool the machine stator in hard conditions.1" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E701D</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($701E) Counter of FAN fail times to cool the machine stator in hard conditions.2">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Sxx_fan_nok_fail_2]]></Comment>
<Sent>
<SentBytes>22701E</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62701E0000</ReplyBytes>
<DataItem Name="($701E) Counter of FAN fail times to cool the machine stator in hard conditions.2" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($701E) Counter of FAN fail times to cool the machine stator in hard conditions.2">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Sxx_fan_nok_fail_2]]></Comment>
<Sent>
<SentBytes>2E701E0000</SentBytes>
<DataItem Name="($701E) Counter of FAN fail times to cool the machine stator in hard conditions.2" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E701E</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($701F) Counter of FAN fail times to cool the machine stator in hard conditions.3">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Sxx_fan_nok_fail_3]]></Comment>
<Sent>
<SentBytes>22701F</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62701F0000</ReplyBytes>
<DataItem Name="($701F) Counter of FAN fail times to cool the machine stator in hard conditions.3" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($701F) Counter of FAN fail times to cool the machine stator in hard conditions.3">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Sxx_fan_nok_fail_3]]></Comment>
<Sent>
<SentBytes>2E701F0000</SentBytes>
<DataItem Name="($701F) Counter of FAN fail times to cool the machine stator in hard conditions.3" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E701F</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7058) 1s average dcdc temperature on break event for post mortem">
<Comment><![CDATA[Read 1s average dcdc temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>227058</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627058000000</ReplyBytes>
<DataItem Name="($7058) 1s average dcdc temperature on break event for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7058) 1s average dcdc temperature on break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write 1s average dcdc temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>2E7058000000</SentBytes>
<DataItem Name="($7058) 1s average dcdc temperature on break event for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7058</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7059) 1s average driver board temperature on break event for post mortem">
<Comment><![CDATA[Read 1s average driver board temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>227059</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627059000000</ReplyBytes>
<DataItem Name="($7059) 1s average driver board temperature on break event for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7059) 1s average driver board temperature on break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write 1s average driver board temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>2E7059000000</SentBytes>
<DataItem Name="($7059) 1s average driver board temperature on break event for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7059</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($705D) 1s average excitation temperature on break event for post mortem">
<Comment><![CDATA[Read 1s average excitation temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>22705D</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62705D000000</ReplyBytes>
<DataItem Name="($705D) 1s average excitation temperature on break event for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($705D) 1s average excitation temperature on break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write 1s average excitation temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>2E705D000000</SentBytes>
<DataItem Name="($705D) 1s average excitation temperature on break event for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E705D</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($705E) 1s average inverter temperature on break event for post mortem">
<Comment><![CDATA[Read 1s average inverter temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>22705E</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62705E000000</ReplyBytes>
<DataItem Name="($705E) 1s average inverter temperature on break event for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($705E) 1s average inverter temperature on break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write 1s average inverter temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>2E705E000000</SentBytes>
<DataItem Name="($705E) 1s average inverter temperature on break event for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E705E</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($705F) 1s average pcb temperature on break event for post mortem">
<Comment><![CDATA[Read 1s average pcb temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>22705F</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62705F000000</ReplyBytes>
<DataItem Name="($705F) 1s average pcb temperature on break event for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($705F) 1s average pcb temperature on break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write 1s average pcb temperature on break event for post mortem]]></Comment>
<Sent>
<SentBytes>2E705F000000</SentBytes>
<DataItem Name="($705F) 1s average pcb temperature on break event for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E705F</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7043) activated downgraded mode FPGA number">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wsx_dm_act_fpga]]></Comment>
<Sent>
<SentBytes>227043</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704300</ReplyBytes>
<DataItem Name="($7043) activated downgraded mode FPGA number" Ref="1" FirstByte="4" BitOffset="4"/>
</Received>
</Request>
<Request Name="DataRead.($7044) activated downgraded mode number">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wsx_dm_act_sfty]]></Comment>
<Sent>
<SentBytes>227044</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704400</ReplyBytes>
<DataItem Name="($7044) activated downgraded mode number" Ref="1" FirstByte="4" BitOffset="4"/>
</Received>
</Request>
<Request Name="DataRead.($7022) Active discharge request from EVC to PEB">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_actv_dchg_req]]></Comment>
<Sent>
<SentBytes>227022</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702200</ReplyBytes>
<DataItem Name="($7022) Active discharge request from EVC to PEB" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($706C) Alim 21 monitoring">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Alim 21 monitoring]]></Comment>
<Sent>
<SentBytes>22706C</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62706C00</ReplyBytes>
<DataItem Name="($706C) Alim 21 monitoring" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($706D) Alim 21 with redundance monitoring">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Alim 21 with redundance monitoring]]></Comment>
<Sent>
<SentBytes>22706D</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62706D00</ReplyBytes>
<DataItem Name="($706D) Alim 21 with redundance monitoring" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($707E) Alimentation 11 state">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Alimentation 11 state]]></Comment>
<Sent>
<SentBytes>22707E</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707E00</ReplyBytes>
<DataItem Name="($707E) Alimentation 11 state" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($707F) Alimentation 21 state">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Alimentation 21 state]]></Comment>
<Sent>
<SentBytes>22707F</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707F00</ReplyBytes>
<DataItem Name="($707F) Alimentation 21 state" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7067) APC and zero torque time counter for post mortem analysis">
<Comment><![CDATA[Read APC and zero torque time counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>227067</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62706700000000</ReplyBytes>
<DataItem Name="($7067) APC and zero torque time counter for post mortem analysis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7067) APC and zero torque time counter for post mortem analysis">
<ManuelSend/>
<Comment><![CDATA[Write APC and zero torque time counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>2E706700000000</SentBytes>
<DataItem Name="($7067) APC and zero torque time counter for post mortem analysis" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7067</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7024) APC state (from CAN)">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_apc_stt]]></Comment>
<Sent>
<SentBytes>227024</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702400</ReplyBytes>
<DataItem Name="($7024) APC state (from CAN)" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($702B) Auto Diag enable">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_auto_diag_ena]]></Comment>
<Sent>
<SentBytes>22702B</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702B00</ReplyBytes>
<DataItem Name="($702B) Auto Diag enable" Ref="1" FirstByte="4" BitOffset="5"/>
</Received>
</Request>
<Request Name="DataRead.($705B) Blocked rotor counter for post mortem">
<Comment><![CDATA[Read Blocked rotor counter for post mortem]]></Comment>
<Sent>
<SentBytes>22705B</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62705B0000</ReplyBytes>
<DataItem Name="($705B) Blocked rotor counter for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($705B) Blocked rotor counter for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Blocked rotor counter for post mortem]]></Comment>
<Sent>
<SentBytes>2E705B0000</SentBytes>
<DataItem Name="($705B) Blocked rotor counter for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E705B</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7081) Bypass mode">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Bypass mode]]></Comment>
<Sent>
<SentBytes>227081</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62708100</ReplyBytes>
<DataItem Name="($7081) Bypass mode" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7081) Bypass mode">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Write Bypass mode]]></Comment>
<Sent>
<SentBytes>2E708100</SentBytes>
<DataItem Name="($7081) Bypass mode" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7081</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7092) CAN Etude activation">
<DossierMaintenabilite/>
<Comment><![CDATA[Read CAN Etude activation]]></Comment>
<Sent>
<SentBytes>227092</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62709200</ReplyBytes>
<DataItem Name="($7092) CAN Etude activation" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7092) CAN Etude activation">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Write CAN Etude activation]]></Comment>
<Sent>
<SentBytes>2E709200</SentBytes>
<DataItem Name="($7092) CAN Etude activation" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7092</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7066) Charge or non zero torque time counter for post mortem analysis">
<Comment><![CDATA[Read Charge or non zero torque time counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>227066</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62706600000000</ReplyBytes>
<DataItem Name="($7066) Charge or non zero torque time counter for post mortem analysis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7066) Charge or non zero torque time counter for post mortem analysis">
<ManuelSend/>
<Comment><![CDATA[Write Charge or non zero torque time counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>2E706600000000</SentBytes>
<DataItem Name="($7066) Charge or non zero torque time counter for post mortem analysis" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7066</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7025) Charge request from EVC to PEB">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_chg_req]]></Comment>
<Sent>
<SentBytes>227025</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702500</ReplyBytes>
<DataItem Name="($7025) Charge request from EVC to PEB" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7049) Combinated current value on the HV Network of Inverter and Excitation">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wxx_i_pwt]]></Comment>
<Sent>
<SentBytes>227049</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270490000</ReplyBytes>
<DataItem Name="($7049) Combinated current value on the HV Network of Inverter and Excitation" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7039) Combination of inverter, Excitation, PCB, MC and DRI temperatures, so in %">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_invt_norm_temp]]></Comment>
<Sent>
<SentBytes>227039</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270390000</ReplyBytes>
<DataItem Name="($7039) Combination of inverter, Excitation, PCB, MC and DRI temperatures, so in %" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($703A) Combination of rotor and stator temperatures, so in %">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_mot_norm_temp]]></Comment>
<Sent>
<SentBytes>22703A</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62703A0000</ReplyBytes>
<DataItem Name="($703A) Combination of rotor and stator temperatures, so in %" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7079) Copy Over voltage protection (before flipflop)">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Copy Over voltage protection (before flipflop)]]></Comment>
<Sent>
<SentBytes>227079</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707900</ReplyBytes>
<DataItem Name="($7079) Copy Over voltage protection (before flipflop)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($708C) Copy Raw rotor position resolver excitation peak voltage">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Copy Raw rotor position resolver excitation peak voltage]]></Comment>
<Sent>
<SentBytes>22708C</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62708C0000</ReplyBytes>
<DataItem Name="($708C) Copy Raw rotor position resolver excitation peak voltage" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($709B) CPU load at 10ms">
<DossierMaintenabilite/>
<Comment><![CDATA[Read CPU load at 10ms]]></Comment>
<Sent>
<SentBytes>22709B</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62709B00</ReplyBytes>
<DataItem Name="($709B) CPU load at 10ms" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7084) DCDC Input current measure">
<DossierMaintenabilite/>
<Comment><![CDATA[Read DCDC Input current measure]]></Comment>
<Sent>
<SentBytes>227084</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270840000</ReplyBytes>
<DataItem Name="($7084) DCDC Input current measure" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7033) DCDC input voltage">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_dcdc_volt_in_mes_raw]]></Comment>
<Sent>
<SentBytes>227033</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270330000</ReplyBytes>
<DataItem Name="($7033) DCDC input voltage" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7085) DCDC output current measure">
<DossierMaintenabilite/>
<Comment><![CDATA[Read DCDC output current measure]]></Comment>
<Sent>
<SentBytes>227085</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270850000</ReplyBytes>
<DataItem Name="($7085) DCDC output current measure" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7086) DCDC power card temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Read DCDC power card temperature]]></Comment>
<Sent>
<SentBytes>227086</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62708600</ReplyBytes>
<DataItem Name="($7086) DCDC power card temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($702E) DCDC state">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_dcdc_stt]]></Comment>
<Sent>
<SentBytes>22702E</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702E00</ReplyBytes>
<DataItem Name="($702E) DCDC state" Ref="1" FirstByte="4" BitOffset="5"/>
</Received>
</Request>
<Request Name="DataRead.($705A) Derating counter for post mortem">
<Comment><![CDATA[Read Derating counter for post mortem]]></Comment>
<Sent>
<SentBytes>22705A</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62705A0000</ReplyBytes>
<DataItem Name="($705A) Derating counter for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($705A) Derating counter for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Derating counter for post mortem]]></Comment>
<Sent>
<SentBytes>2E705A0000</SentBytes>
<DataItem Name="($705A) Derating counter for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E705A</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($706E) DID for activation of bypass frame">
<DossierMaintenabilite/>
<Comment><![CDATA[Read DID for activation of bypass frame]]></Comment>
<Sent>
<SentBytes>22706E</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62706E00</ReplyBytes>
<DataItem Name="($706E) DID for activation of bypass frame" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($706E) DID for activation of bypass frame">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Write DID for activation of bypass frame]]></Comment>
<Sent>
<SentBytes>2E706E00</SentBytes>
<DataItem Name="($706E) DID for activation of bypass frame" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E706E</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7023) Effective active discharge feedback to EVC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_actv_dchg_stt]]></Comment>
<Sent>
<SentBytes>227023</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702300</ReplyBytes>
<DataItem Name="($7023) Effective active discharge feedback to EVC" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7026) Effective Charge feedback to EVC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_chg_stt]]></Comment>
<Sent>
<SentBytes>227026</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702600</ReplyBytes>
<DataItem Name="($7026) Effective Charge feedback to EVC" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7046) Excitation Current Default">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wsx_i_f_dfl_sfty]]></Comment>
<Sent>
<SentBytes>227046</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704600</ReplyBytes>
<DataItem Name="($7046) Excitation Current Default" Ref="1" FirstByte="4" BitOffset="5"/>
</Received>
</Request>
<Request Name="DataRead.($7098) Excitation currents safety check">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Excitation currents safety check]]></Comment>
<Sent>
<SentBytes>227098</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62709800</ReplyBytes>
<DataItem Name="($7098) Excitation currents safety check" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($707A) Excitation driver state (ready or not)">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Excitation driver state (ready or not)]]></Comment>
<Sent>
<SentBytes>22707A</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707A00</ReplyBytes>
<DataItem Name="($707A) Excitation driver state (ready or not)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($706F) Excitation high arm IGBT driver fault">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Excitation high arm IGBT driver fault]]></Comment>
<Sent>
<SentBytes>22706F</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62706F00</ReplyBytes>
<DataItem Name="($706F) Excitation high arm IGBT driver fault" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7070) Excitation low arm IGBT driver fault">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Excitation low arm IGBT driver fault]]></Comment>
<Sent>
<SentBytes>227070</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707000</ReplyBytes>
<DataItem Name="($7070) Excitation low arm IGBT driver fault" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7073) Excitation over current protection (before flipflop) High">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Excitation over current protection (before flipflop) High]]></Comment>
<Sent>
<SentBytes>227073</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707300</ReplyBytes>
<DataItem Name="($7073) Excitation over current protection (before flipflop) High" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7074) Excitation over current protection (before flipflop) Low">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Excitation over current protection (before flipflop) Low]]></Comment>
<Sent>
<SentBytes>227074</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707400</ReplyBytes>
<DataItem Name="($7074) Excitation over current protection (before flipflop) Low" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($702D) Failure class of the DCDC converter">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_dcdc_err_stt]]></Comment>
<Sent>
<SentBytes>22702D</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702D00</ReplyBytes>
<DataItem Name="($702D) Failure class of the DCDC converter" Ref="1" FirstByte="4" BitOffset="5"/>
</Received>
</Request>
<Request Name="DataRead.($7030) Failure class of the Inverter">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_invt_flt_typ]]></Comment>
<Sent>
<SentBytes>227030</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62703000</ReplyBytes>
<DataItem Name="($7030) Failure class of the Inverter" Ref="1" FirstByte="4" BitOffset="5"/>
</Received>
</Request>
<Request Name="DataRead.($7082) FPGA fault sent by SPI">
<DossierMaintenabilite/>
<Comment><![CDATA[Read FPGA fault sent by SPI]]></Comment>
<Sent>
<SentBytes>227082</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62708200</ReplyBytes>
<DataItem Name="($7082) FPGA fault sent by SPI" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($708A) FPGA firmware version Identifier">
<DossierMaintenabilite/>
<Comment><![CDATA[Read FPGA firmware version Identifier]]></Comment>
<Sent>
<SentBytes>22708A</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62708A0000</ReplyBytes>
<DataItem Name="($708A) FPGA firmware version Identifier" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($709C) Gestion of current sensors">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Gestion of current sensors]]></Comment>
<Sent>
<SentBytes>22709C</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62709C00</ReplyBytes>
<DataItem Name="($709C) Gestion of current sensors" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7069) Hardware (by the fpga) overcurrent protection counter for post mortem analysis">
<Comment><![CDATA[Read Hardware (by the fpga) overcurrent protection counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>227069</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270690000</ReplyBytes>
<DataItem Name="($7069) Hardware (by the fpga) overcurrent protection counter for post mortem analysis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7069) Hardware (by the fpga) overcurrent protection counter for post mortem analysis">
<ManuelSend/>
<Comment><![CDATA[Write Hardware (by the fpga) overcurrent protection counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>2E70690000</SentBytes>
<DataItem Name="($7069) Hardware (by the fpga) overcurrent protection counter for post mortem analysis" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7069</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($706A) Hardware (by the fpga) overvoltage protection counter for post mortem analysis">
<Comment><![CDATA[Read Hardware (by the fpga) overvoltage protection counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>22706A</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62706A0000</ReplyBytes>
<DataItem Name="($706A) Hardware (by the fpga) overvoltage protection counter for post mortem analysis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($706A) Hardware (by the fpga) overvoltage protection counter for post mortem analysis">
<ManuelSend/>
<Comment><![CDATA[Write Hardware (by the fpga) overvoltage protection counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>2E706A0000</SentBytes>
<DataItem Name="($706A) Hardware (by the fpga) overvoltage protection counter for post mortem analysis" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E706A</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($702F) High Voltage Network Default">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_hv_dfl_sfty]]></Comment>
<Sent>
<SentBytes>22702F</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702F00</ReplyBytes>
<DataItem Name="($702F) High Voltage Network Default" Ref="1" FirstByte="4" BitOffset="4"/>
</Received>
</Request>
<Request Name="DataRead.($7031) Interlock plug service status, from LBC (condition for reprogramming)">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_lbc_ilck_stt]]></Comment>
<Sent>
<SentBytes>227031</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62703100</ReplyBytes>
<DataItem Name="($7031) Interlock plug service status, from LBC (condition for reprogramming)" Ref="1" FirstByte="4" BitOffset="6"/>
</Received>
</Request>
<Request Name="DataRead.($7083) INV Automation State">
<DossierMaintenabilite/>
<Comment><![CDATA[Read INV Automaton State]]></Comment>
<Sent>
<SentBytes>227083</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62708300</ReplyBytes>
<DataItem Name="($7083) INV Automation State" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7071) Inverter high arm IGBT driver fault">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Inverter high arm IGBT driver fault]]></Comment>
<Sent>
<SentBytes>227071</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707100</ReplyBytes>
<DataItem Name="($7071) Inverter high arm IGBT driver fault" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($707B) Inverter high IGBT driver state (ready or not)">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Inverter high IGBT driver state (ready or not)]]></Comment>
<Sent>
<SentBytes>22707B</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707B00</ReplyBytes>
<DataItem Name="($707B) Inverter high IGBT driver state (ready or not)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7072) Inverter low arm IGBT driver fault">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Inverter low arm IGBT driver fault]]></Comment>
<Sent>
<SentBytes>227072</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707200</ReplyBytes>
<DataItem Name="($7072) Inverter low arm IGBT driver fault" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($707C) Inverter low IGBT driver state (ready or not)">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Inverter low IGBT driver state (ready or not)]]></Comment>
<Sent>
<SentBytes>22707C</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707C00</ReplyBytes>
<DataItem Name="($707C) Inverter low IGBT driver state (ready or not)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7075) Inverter over current protection (before flipflop) Arm U">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Inverter over current protection (before flipflop) Arm U]]></Comment>
<Sent>
<SentBytes>227075</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707500</ReplyBytes>
<DataItem Name="($7075) Inverter over current protection (before flipflop) Arm U" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7076) Inverter over current protection (before flipflop) Arm V">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Inverter over current protection (before flipflop) Arm V]]></Comment>
<Sent>
<SentBytes>227076</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707600</ReplyBytes>
<DataItem Name="($7076) Inverter over current protection (before flipflop) Arm V" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7077) Inverter over current protection (before flipflop) Arm W">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Inverter over current protection (before flipflop) Arm W]]></Comment>
<Sent>
<SentBytes>227077</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707700</ReplyBytes>
<DataItem Name="($7077) Inverter over current protection (before flipflop) Arm W" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7091) Last driver board temperature on 1s in the minute before break event for post mortem">
<Comment><![CDATA[Read Last driver board temperature on 1s in the minute before break event for post mortem]]></Comment>
<Sent>
<SentBytes>227091</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627091000000</ReplyBytes>
<DataItem Name="($7091) Last driver board temperature on 1s in the minute before break event for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7091) Last driver board temperature on 1s in the minute before break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Last driver board temperature on 1s in the minute before break event for post mortem]]></Comment>
<Sent>
<SentBytes>2E7091000000</SentBytes>
<DataItem Name="($7091) Last driver board temperature on 1s in the minute before break event for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7091</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($709A) Max CPU load at 10ms">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Max CPU load at 10ms]]></Comment>
<Sent>
<SentBytes>22709A</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62709A00</ReplyBytes>
<DataItem Name="($709A) Max CPU load at 10ms" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70A1) Max of 10ms task (Vtx_TaskMaxDurationIT_A[3])">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Max of 10ms task (Vtx_TaskMaxDurationIT_A[3])]]></Comment>
<Sent>
<SentBytes>2270A1</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A10000</ReplyBytes>
<DataItem Name="($70A1) Max of 10ms task (Vtx_TaskMaxDurationIT_A[3])" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($709F) Max of CPU load in micro-seconds (Vtx_TaskMaxDurationIT_A[12])">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Max of CPU load in micro-seconds (Vtx_TaskMaxDurationIT_A[12])]]></Comment>
<Sent>
<SentBytes>22709F</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62709F0000</ReplyBytes>
<DataItem Name="($709F) Max of CPU load in micro-seconds (Vtx_TaskMaxDurationIT_A[12])" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7035) Maximal available calculated torque in generator mode">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_emot_max_gen_tq]]></Comment>
<Sent>
<SentBytes>227035</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62703500</ReplyBytes>
<DataItem Name="($7035) Maximal available calculated torque in generator mode" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7036) Maximal available calculated torque in motor mode">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_emot_max_mot_tq]]></Comment>
<Sent>
<SentBytes>227036</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62703600</ReplyBytes>
<DataItem Name="($7036) Maximal available calculated torque in motor mode" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7061) Maximum driver board temperature during last derating">
<Comment><![CDATA[Read Maximum driver board temperature during last derating]]></Comment>
<Sent>
<SentBytes>227061</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627061000000</ReplyBytes>
<DataItem Name="($7061) Maximum driver board temperature during last derating" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7061) Maximum driver board temperature during last derating">
<ManuelSend/>
<Comment><![CDATA[Write Maximum driver board temperature during last derating]]></Comment>
<Sent>
<SentBytes>2E7061000000</SentBytes>
<DataItem Name="($7061) Maximum driver board temperature during last derating" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7061</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7062) Maximum excitation temperature during last derating">
<Comment><![CDATA[Read Maximum excitation temperature during last derating]]></Comment>
<Sent>
<SentBytes>227062</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627062000000</ReplyBytes>
<DataItem Name="($7062) Maximum excitation temperature during last derating" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7062) Maximum excitation temperature during last derating">
<ManuelSend/>
<Comment><![CDATA[Write Maximum excitation temperature during last derating]]></Comment>
<Sent>
<SentBytes>2E7062000000</SentBytes>
<DataItem Name="($7062) Maximum excitation temperature during last derating" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7062</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($70A5) Maximum instant value of normalized torque for cell overvoltage">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Vxx_norm_tq_max_cell_ov_fac]]></Comment>
<Sent>
<SentBytes>2270A5</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A50000</ReplyBytes>
<DataItem Name="($70A5) Maximum instant value of normalized torque for cell overvoltage" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70A6) Maximum instant value of normalized torque for temperature derating">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Vxx_norm_tq_max_temp]]></Comment>
<Sent>
<SentBytes>2270A6</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A60000</ReplyBytes>
<DataItem Name="($70A6) Maximum instant value of normalized torque for temperature derating" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70A7) Maximum instant value of normalized torque for voltage derating">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Vxx_norm_tq_max_udc]]></Comment>
<Sent>
<SentBytes>2270A7</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A70000</ReplyBytes>
<DataItem Name="($70A7) Maximum instant value of normalized torque for voltage derating" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7063) Maximum inverter temperature during last derating">
<Comment><![CDATA[Read Maximum inverter temperature during last derating]]></Comment>
<Sent>
<SentBytes>227063</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627063000000</ReplyBytes>
<DataItem Name="($7063) Maximum inverter temperature during last derating" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7063) Maximum inverter temperature during last derating">
<ManuelSend/>
<Comment><![CDATA[Write Maximum inverter temperature during last derating]]></Comment>
<Sent>
<SentBytes>2E7063000000</SentBytes>
<DataItem Name="($7063) Maximum inverter temperature during last derating" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7063</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($70A3) Maximum normalized torque corresponding to max current saturation value">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Vxx_norm_tq_cur_sat_max]]></Comment>
<Sent>
<SentBytes>2270A3</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A30000</ReplyBytes>
<DataItem Name="($70A3) Maximum normalized torque corresponding to max current saturation value" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7064) Maximum pcb temperature during last derating">
<Comment><![CDATA[Read Maximum pcb temperature during last derating]]></Comment>
<Sent>
<SentBytes>227064</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627064000000</ReplyBytes>
<DataItem Name="($7064) Maximum pcb temperature during last derating" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7064) Maximum pcb temperature during last derating">
<ManuelSend/>
<Comment><![CDATA[Write Maximum pcb temperature during last derating]]></Comment>
<Sent>
<SentBytes>2E7064000000</SentBytes>
<DataItem Name="($7064) Maximum pcb temperature during last derating" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7064</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7065) Maximum water temperature during last derating">
<Comment><![CDATA[Read Maximum water temperature during last derating]]></Comment>
<Sent>
<SentBytes>227065</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627065000000</ReplyBytes>
<DataItem Name="($7065) Maximum water temperature during last derating" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7065) Maximum water temperature during last derating">
<ManuelSend/>
<Comment><![CDATA[Write Maximum water temperature during last derating]]></Comment>
<Sent>
<SentBytes>2E7065000000</SentBytes>
<DataItem Name="($7065) Maximum water temperature during last derating" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7065</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($70A8) Minimum instant value of normalized torque for cell overvoltage">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Vxx_norm_tq_min_cell_ov_fac]]></Comment>
<Sent>
<SentBytes>2270A8</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A80000</ReplyBytes>
<DataItem Name="($70A8) Minimum instant value of normalized torque for cell overvoltage" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70A4) Minimum normalized torque corresponding to max current saturation value">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Vxx_norm_tq_cur_sat_min]]></Comment>
<Sent>
<SentBytes>2270A4</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A40000</ReplyBytes>
<DataItem Name="($70A4) Minimum normalized torque corresponding to max current saturation value" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($703E) Mode of the power train (motor or generator)">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_emot_mod]]></Comment>
<Sent>
<SentBytes>22703E</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62703E00</ReplyBytes>
<DataItem Name="($703E) Mode of the power train (motor or generator)" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7096) Normalized inverter-Excitation temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Normalized inverter-Excitation temperature]]></Comment>
<Sent>
<SentBytes>227096</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270960000</ReplyBytes>
<DataItem Name="($7096) Normalized inverter-Excitation temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7097) Normalized PCB-Micro_driverboard temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Normalized PCB-Micro_driverboard temperature]]></Comment>
<Sent>
<SentBytes>227097</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270970000</ReplyBytes>
<DataItem Name="($7097) Normalized PCB-Micro_driverboard temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7093) Number of Derating CFA functionnal failure 1 cycles saved">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Number of Derating CFA functionnal failure 1 cycles saved]]></Comment>
<Sent>
<SentBytes>227093</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270930000</ReplyBytes>
<DataItem Name="($7093) Number of Derating CFA functionnal failure 1 cycles saved" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7093) Number of Derating CFA functionnal failure 1 cycles saved">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Write Number of Derating CFA functionnal failure 1 cycles saved]]></Comment>
<Sent>
<SentBytes>2E70930000</SentBytes>
<DataItem Name="($7093) Number of Derating CFA functionnal failure 1 cycles saved" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7093</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7094) Number of Derating CFA functionnal failure 2 cycles saved">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Number of Derating CFA functionnal failure 2 cycles saved]]></Comment>
<Sent>
<SentBytes>227094</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270940000</ReplyBytes>
<DataItem Name="($7094) Number of Derating CFA functionnal failure 2 cycles saved" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7094) Number of Derating CFA functionnal failure 2 cycles saved">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Write Number of Derating CFA functionnal failure 2 cycles saved]]></Comment>
<Sent>
<SentBytes>2E70940000</SentBytes>
<DataItem Name="($7094) Number of Derating CFA functionnal failure 2 cycles saved" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7094</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7095) Number of Derating CFA functionnal failure 3 cycles saved">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Number of Derating CFA functionnal failure 3 cycles saved]]></Comment>
<Sent>
<SentBytes>227095</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270950000</ReplyBytes>
<DataItem Name="($7095) Number of Derating CFA functionnal failure 3 cycles saved" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7095) Number of Derating CFA functionnal failure 3 cycles saved">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Write Number of Derating CFA functionnal failure 3 cycles saved]]></Comment>
<Sent>
<SentBytes>2E70950000</SentBytes>
<DataItem Name="($7095) Number of Derating CFA functionnal failure 3 cycles saved" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7095</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($70CA) Number of the bloc which has nvrol error">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Number of the bloc which has nvrol error [Vxx_inv_nvrol_err_bloc]]]></Comment>
<Sent>
<SentBytes>2270CA</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>6270CA00</ReplyBytes>
<DataItem Name="($70CA) Number of the bloc which has nvrol error" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7087) Observer estimation for stack rotor temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Observer estimation for stack rotor temperature]]></Comment>
<Sent>
<SentBytes>227087</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270870000</ReplyBytes>
<DataItem Name="($7087) Observer estimation for stack rotor temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7029) On/Off power train activation request from EVC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_invt_act]]></Comment>
<Sent>
<SentBytes>227029</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702900</ReplyBytes>
<DataItem Name="($7029) On/Off power train activation request from EVC" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($705C) Water overheat temperature counter for post mortem">
<Comment><![CDATA[Read Water overheat temperature counter for post mortem]]></Comment>
<Sent>
<SentBytes>22705C</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62705C0000</ReplyBytes>
<DataItem Name="($705C) Water overheat temperature counter for post mortem" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($705C) Water overheat temperature counter for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Water overheat temperature counter for post mortem]]></Comment>
<Sent>
<SentBytes>2E705C0000</SentBytes>
<DataItem Name="($705C) Water overheat temperature counter for post mortem" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E705C</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7027) On/Off request of the DCDC from EVC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_dcdc_actv_req_evc]]></Comment>
<Sent>
<SentBytes>227027</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702700</ReplyBytes>
<DataItem Name="($7027) On/Off request of the DCDC from EVC" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($708F) Opening relays wire request">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Opening relays wire request]]></Comment>
<Sent>
<SentBytes>22708F</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62708F00</ReplyBytes>
<DataItem Name="($708F) Opening relays wire request" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70A9) Vxx_invt_rst_ctx_5">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Vxx_invt_rst_ctx_5]]></Comment>
<Sent>
<SentBytes>2270A9</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A90000</ReplyBytes>
<DataItem Name="($70A9) Vxx_invt_rst_ctx_5" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem">
<Comment><![CDATA[Read Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>227055</SentBytes>
</Sent>
<Received MinBytes="18">
<ReplyBytes>627055000000000000000000000000000000</ReplyBytes>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.0" Ref="1" FirstByte="16"/>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.1" Ref="1" FirstByte="13"/>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.2" Ref="1" FirstByte="10"/>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.3" Ref="1" FirstByte="7"/>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.4" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>2E7055000000000000000000000000000000</SentBytes>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.0" FirstByte="16"/>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.1" FirstByte="13"/>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.2" FirstByte="10"/>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.3" FirstByte="7"/>
<DataItem Name="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.4" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7055</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem">
<Comment><![CDATA[Read Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>227054</SentBytes>
</Sent>
<Received MinBytes="18">
<ReplyBytes>627054000000000000000000000000000000</ReplyBytes>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.0" Ref="1" FirstByte="16"/>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.1" Ref="1" FirstByte="13"/>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.2" Ref="1" FirstByte="10"/>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.3" Ref="1" FirstByte="7"/>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.4" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>2E7054000000000000000000000000000000</SentBytes>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.0" FirstByte="16"/>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.1" FirstByte="13"/>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.2" FirstByte="10"/>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.3" FirstByte="7"/>
<DataItem Name="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.4" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7054</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem">
<Comment><![CDATA[Read Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>227053</SentBytes>
</Sent>
<Received MinBytes="18">
<ReplyBytes>627053000000000000000000000000000000</ReplyBytes>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.0" Ref="1" FirstByte="16"/>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.1" Ref="1" FirstByte="13"/>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.2" Ref="1" FirstByte="10"/>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.3" Ref="1" FirstByte="7"/>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.4" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>2E7053000000000000000000000000000000</SentBytes>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.0" FirstByte="16"/>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.1" FirstByte="13"/>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.2" FirstByte="10"/>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.3" FirstByte="7"/>
<DataItem Name="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.4" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7053</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem">
<Comment><![CDATA[Read Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem]]></Comment>
<Sent>
<SentBytes>227052</SentBytes>
</Sent>
<Received MinBytes="18">
<ReplyBytes>627052000000000000000000000000000000</ReplyBytes>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.4" Ref="1" FirstByte="4"/>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.0" Ref="1" FirstByte="16"/>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.1" Ref="1" FirstByte="13"/>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.2" Ref="1" FirstByte="10"/>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.3" Ref="1" FirstByte="7"/>
</Received>
</Request>
<Request Name="DataWrite.($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem]]></Comment>
<Sent>
<SentBytes>2E7052000000000000000000000000000000</SentBytes>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.4" FirstByte="4"/>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.0" FirstByte="16"/>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.1" FirstByte="13"/>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.2" FirstByte="10"/>
<DataItem Name="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.3" FirstByte="7"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7052</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7050) Value for reference rotor resistance (for safety monitoring)">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Sxx_rot_r_ref_sfty]]></Comment>
<Sent>
<SentBytes>227050</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270500000</ReplyBytes>
<DataItem Name="($7050) Value for reference rotor resistance (for safety monitoring)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7034) Voltage demand for the DCDC converter from the EVC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_dcdc_volt_sp]]></Comment>
<Sent>
<SentBytes>227034</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270340000</ReplyBytes>
<DataItem Name="($7034) Voltage demand for the DCDC converter from the EVC" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($703C) Vehicle distance totalizer from EVC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_vh_dist]]></Comment>
<Sent>
<SentBytes>22703C</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62703C000000</ReplyBytes>
<DataItem Name="($703C) Vehicle distance totalizer from EVC" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem">
<Comment><![CDATA[Read Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>227057</SentBytes>
</Sent>
<Received MinBytes="18">
<ReplyBytes>627057000000000000000000000000000000</ReplyBytes>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.0" Ref="1" FirstByte="16"/>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.1" Ref="1" FirstByte="13"/>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.2" Ref="1" FirstByte="10"/>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.3" Ref="1" FirstByte="7"/>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.4" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>2E7057000000000000000000000000000000</SentBytes>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.0" FirstByte="16"/>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.1" FirstByte="13"/>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.2" FirstByte="10"/>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.3" FirstByte="7"/>
<DataItem Name="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.4" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7057</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem">
<Comment><![CDATA[Read Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>227056</SentBytes>
</Sent>
<Received MinBytes="18">
<ReplyBytes>627056000000000000000000000000000000</ReplyBytes>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.0" Ref="1" FirstByte="16"/>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.1" Ref="1" FirstByte="13"/>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.2" Ref="1" FirstByte="10"/>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.3" Ref="1" FirstByte="7"/>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.4" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem">
<ManuelSend/>
<Comment><![CDATA[Write Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.0]]></Comment>
<Sent>
<SentBytes>2E7056000000000000000000000000000000</SentBytes>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.0" FirstByte="16"/>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.1" FirstByte="13"/>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.2" FirstByte="10"/>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.3" FirstByte="7"/>
<DataItem Name="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.4" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7056</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7045) Validity status of the rotor electrical rotation speed">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_emot_n_dfl_sfty]]></Comment>
<Sent>
<SentBytes>227045</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704500</ReplyBytes>
<DataItem Name="($7045) Validity status of the rotor electrical rotation speed" Ref="1" FirstByte="4" BitOffset="6"/>
</Received>
</Request>
<Request Name="DataRead.($7048) Validity status of the rotor electrical angular position">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wsx_theta_dfl_sfty]]></Comment>
<Sent>
<SentBytes>227048</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704800</ReplyBytes>
<DataItem Name="($7048) Validity status of the rotor electrical angular position" Ref="1" FirstByte="4" BitOffset="6"/>
</Received>
</Request>
<Request Name="DataRead.($7032) Torque Default">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vsx_tq_dfl_sfty]]></Comment>
<Sent>
<SentBytes>227032</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62703200</ReplyBytes>
<DataItem Name="($7032) Torque Default" Ref="1" FirstByte="4" BitOffset="4"/>
</Received>
</Request>
<Request Name="DataRead.($7078) Over voltage protection (before flipflop)">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Over voltage protection (before flipflop)]]></Comment>
<Sent>
<SentBytes>227078</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707800</ReplyBytes>
<DataItem Name="($7078) Over voltage protection (before flipflop)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7047) Phase Current Default">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wsx_i_mot_ph_dfl_sfty]]></Comment>
<Sent>
<SentBytes>227047</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704700</ReplyBytes>
<DataItem Name="($7047) Phase Current Default" Ref="1" FirstByte="4" BitOffset="4"/>
</Received>
</Request>
<Request Name="DataRead.($7099) Phase currents safety check">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Phase currents safety check]]></Comment>
<Sent>
<SentBytes>227099</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62709900</ReplyBytes>
<DataItem Name="($7099) Phase currents safety check" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7051) Position sensor type">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Position sensor type]]></Comment>
<Sent>
<SentBytes>227051</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62705100</ReplyBytes>
<DataItem Name="($7051) Position sensor type" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7051) Position sensor type">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Write Position sensor type]]></Comment>
<Sent>
<SentBytes>2E705100</SentBytes>
<DataItem Name="($7051) Position sensor type" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7051</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($704C) Received rotor reference resistance CRC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_rot_r_ref_crc_rcp]]></Comment>
<Sent>
<SentBytes>22704C</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704C00</ReplyBytes>
<DataItem Name="($704C) Received rotor reference resistance CRC" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($704C) Received rotor reference resistance CRC">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Vxx_rot_r_ref_crc_rcp]]></Comment>
<Sent>
<SentBytes>2E704C00</SentBytes>
<DataItem Name="($704C) Received rotor reference resistance CRC" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E704C</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($704B) Received TETA position offset">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_emot_psn_ofs_rcp]]></Comment>
<Sent>
<SentBytes>22704B</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62704B0000</ReplyBytes>
<DataItem Name="($704B) Received TETA position offset" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($704B) Received TETA position offset">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Vxx_emot_psn_ofs_rcp]]></Comment>
<Sent>
<SentBytes>2E704B0000</SentBytes>
<DataItem Name="($704B) Received TETA position offset" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E704B</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($704D) Received value for reference rotor resistance">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_rot_r_ref_rcp]]></Comment>
<Sent>
<SentBytes>22704D</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62704D0000</ReplyBytes>
<DataItem Name="($704D) Received value for reference rotor resistance" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($704D) Received value for reference rotor resistance">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Vxx_rot_r_ref_rcp]]></Comment>
<Sent>
<SentBytes>2E704D0000</SentBytes>
<DataItem Name="($704D) Received value for reference rotor resistance" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E704D</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($709D) redundant supply 21 failure counter for post mortem analysis">
<Comment><![CDATA[Read redundant supply 21 failure counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>22709D</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62709D0000</ReplyBytes>
<DataItem Name="($709D) redundant supply 21 failure counter for post mortem analysis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($703B) Resistance rotor learning + CRC written by diag tool">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_rot_r_ref_rcp]]></Comment>
<Sent>
<SentBytes>22703B</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62703B000000</ReplyBytes>
<DataItem Name="($703B) Resistance rotor learning + CRC written by diag tool.1" Ref="1" FirstByte="4"/>
<DataItem Name="($703B) Resistance rotor learning + CRC written by diag tool.2" Ref="1" FirstByte="6"/>
</Received>
</Request>
<Request Name="DataWrite.($703B) Resistance rotor learning + CRC written by diag tool">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Vxx_rot_r_ref_rcp]]></Comment>
<Sent>
<SentBytes>2E703B000000</SentBytes>
<DataItem Name="($703B) Resistance rotor learning + CRC written by diag tool.1" FirstByte="4"/>
<DataItem Name="($703B) Resistance rotor learning + CRC written by diag tool.2" FirstByte="6"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E703B</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7088) Rotor copper temperature estimation">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Rotor copper temperature estimation]]></Comment>
<Sent>
<SentBytes>227088</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270880000</ReplyBytes>
<DataItem Name="($7088) Rotor copper temperature estimation" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7038) Rotor copper temperature raw estimation">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_esti_rot_cu_temp_raw]]></Comment>
<Sent>
<SentBytes>227038</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270380000</ReplyBytes>
<DataItem Name="($7038) Rotor copper temperature raw estimation" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7041) Rotor overcurrent validated">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wbx_sw_ocp_exct_mem]]></Comment>
<Sent>
<SentBytes>227041</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704100</ReplyBytes>
<DataItem Name="($7041) Rotor overcurrent validated" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($708B) Rotor position measure">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Rotor position measure]]></Comment>
<Sent>
<SentBytes>22708B</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62708B0000</ReplyBytes>
<DataItem Name="($708B) Rotor position measure" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($708D) Rotor position measure (for safety monitoring)">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Rotor position measure (for safety monitoring)]]></Comment>
<Sent>
<SentBytes>22708D</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62708D0000</ReplyBytes>
<DataItem Name="($708D) Rotor position measure (for safety monitoring)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7037) Rotor position offset learning + CRC written by diag tool">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_emot_psn_ofs_rcp]]></Comment>
<Sent>
<SentBytes>227037</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627037000000</ReplyBytes>
<DataItem Name="($7037) Rotor position offset learning + CRC written by diag tool.1" Ref="1" FirstByte="4"/>
<DataItem Name="($7037) Rotor position offset learning + CRC written by diag tool.2" Ref="1" FirstByte="6"/>
</Received>
</Request>
<Request Name="DataWrite.($7037) Rotor position offset learning + CRC written by diag tool">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Vxx_emot_psn_ofs_rcp]]></Comment>
<Sent>
<SentBytes>2E7037000000</SentBytes>
<DataItem Name="($7037) Rotor position offset learning + CRC written by diag tool.1" FirstByte="4"/>
<DataItem Name="($7037) Rotor position offset learning + CRC written by diag tool.2" FirstByte="6"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7037</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($7021) Saved resistance rotor">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Saved resistance rotor]]></Comment>
<Sent>
<SentBytes>227021</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>627021</ReplyBytes>
<DataItem Name="($7021) Saved resistance rotor.value" Ref="1" FirstByte="4"/>
<DataItem Name="($7021) Saved resistance rotor.CRC" Ref="1" FirstByte="6"/>
</Received>
</Request>
<Request Name="DataRead.($709E) SeedBreaker to explain the reset cause">
<DossierMaintenabilite/>
<Comment><![CDATA[Read SeedBreaker to explain the reset cause]]></Comment>
<Sent>
<SentBytes>22709E</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62709E0000</ReplyBytes>
<DataItem Name="($709E) SeedBreaker to explain the reset cause" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7068) Software overcurrent protection counter for post mortem analysis">
<Comment><![CDATA[Read Software overcurrent protection counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>227068</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270680000</ReplyBytes>
<DataItem Name="($7068) Software overcurrent protection counter for post mortem analysis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($7068) Software overcurrent protection counter for post mortem analysis">
<ManuelSend/>
<Comment><![CDATA[Write Software overcurrent protection counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>2E70680000</SentBytes>
<DataItem Name="($7068) Software overcurrent protection counter for post mortem analysis" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E7068</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($706B) Software overvoltage protection counter for post mortem analysis">
<Comment><![CDATA[Read Software overvoltage protection counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>22706B</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>62706B0000</ReplyBytes>
<DataItem Name="($706B) Software overvoltage protection counter for post mortem analysis" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($706B) Software overvoltage protection counter for post mortem analysis">
<ManuelSend/>
<Comment><![CDATA[Write Software overvoltage protection counter for post mortem analysis]]></Comment>
<Sent>
<SentBytes>2E706B0000</SentBytes>
<DataItem Name="($706B) Software overvoltage protection counter for post mortem analysis" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E706B</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($708E) Spare signal for driver board temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Spare signal for driver board temperature]]></Comment>
<Sent>
<SentBytes>22708E</SentBytes>
</Sent>
<Received MinBytes="6">
<ReplyBytes>62708E000000</ReplyBytes>
<DataItem Name="($708E) Spare signal for driver board temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($703F) SPI communication default">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wbx_spi_dfl_sfty]]></Comment>
<Sent>
<SentBytes>22703F</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62703F00</ReplyBytes>
<DataItem Name="($703F) SPI communication default" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7089) Stator copper temperature estimation">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Stator copper temperature estimation]]></Comment>
<Sent>
<SentBytes>227089</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270890000</ReplyBytes>
<DataItem Name="($7089) Stator copper temperature estimation" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7042) Stator overcurrent validated">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Wbx_sw_ocp_invt_mem]]></Comment>
<Sent>
<SentBytes>227042</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704200</ReplyBytes>
<DataItem Name="($7042) Stator overcurrent validated" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($7028) status verlog from PEB to EVC">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_eng_run_ena_swlk]]></Comment>
<Sent>
<SentBytes>227028</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702800</ReplyBytes>
<DataItem Name="($7028) status verlog from PEB to EVC" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($707D) Supply monitoring default">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Supply monitoring default]]></Comment>
<Sent>
<SentBytes>22707D</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62707D00</ReplyBytes>
<DataItem Name="($707D) Supply monitoring default" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($704A) TETA CRC received">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_emot_psn_ofs_crc_rcp]]></Comment>
<Sent>
<SentBytes>22704A</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62704A00</ReplyBytes>
<DataItem Name="($704A) TETA CRC received" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($704A) TETA CRC received">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Request $2E - Vxx_emot_psn_ofs_crc_rcp]]></Comment>
<Sent>
<SentBytes>2E704A00</SentBytes>
<DataItem Name="($704A) TETA CRC received" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E704A</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($703D) The water temperature produced by the Rectifier">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vxx_wtr_temp]]></Comment>
<Sent>
<SentBytes>22703D</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62703D00</ReplyBytes>
<DataItem Name="($703D) The water temperature produced by the Rectifier" Ref="1" FirstByte="4" BitOffset="1"/>
</Received>
</Request>
<Request Name="DataRead.($70D7) HVNetworkVoltage from Battery">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70D7) HVNetworkVoltage from Battery]]></Comment>
<Sent>
<SentBytes>2270D7</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270D70000</ReplyBytes>
<DataItem Name="($70D7) HVNetworkVoltage from Battery" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70D8) HVNetworkVoltage from DCDC">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70D8) HVNetworkVoltage from DCDC]]></Comment>
<Sent>
<SentBytes>2270D8</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270D80000</ReplyBytes>
<DataItem Name="($70D8) HVNetworkVoltage from DCDC" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70E7) Normalized rotor temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70E7) Normalized rotor temperature]]></Comment>
<Sent>
<SentBytes>2270E7</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270E70000</ReplyBytes>
<DataItem Name="($70E7) Normalized rotor temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70D6) Rotor Positions Diag">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70D6)Rotor Positions Diag]]></Comment>
<Sent>
<SentBytes>2270D6</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>6270D600</ReplyBytes>
<DataItem Name="($70D6) Rotor Positions Diag" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70D5) Rotor position sensor safety check">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Rotor position sensor safety check]]></Comment>
<Sent>
<SentBytes>2270D5</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>6270D500</ReplyBytes>
<DataItem Name="($70D5) Rotor position sensor safety check" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70E8) Stator temperature sensor 1 for freeze frame management">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70E8) Stator temperature sensor 1 for freeze frame management]]></Comment>
<Sent>
<SentBytes>2270E8</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270E80000</ReplyBytes>
<DataItem Name="($70E8) Stator temperature sensor 1 for freeze frame management" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70E9) Stator temperature sensor 2 for freeze frame management">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70E9) Stator temperature sensor 2 for freeze frame management]]></Comment>
<Sent>
<SentBytes>2270E9</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270E90000</ReplyBytes>
<DataItem Name="($70E9) Stator temperature sensor 2 for freeze frame management" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70EA) spare signal for driver board temperature for freeze frame management">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70EA) spare signal for driver board temperature for freeze frame management]]></Comment>
<Sent>
<SentBytes>2270EA</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270EA0000</ReplyBytes>
<DataItem Name="($70EA) spare signal for driver board temperature for freeze frame management" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70EB) Excitation temperature for freeze frame management">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70EB) Excitation temperature for freeze frame management]]></Comment>
<Sent>
<SentBytes>2270EB</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270EB0000</ReplyBytes>
<DataItem Name="($70EB) Excitation temperature for freeze frame management" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70EC) Inverter temperature sensor 1 for freeze frame management">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70EC) Inverter temperature sensor 1 for freeze frame management]]></Comment>
<Sent>
<SentBytes>2270EC</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270EC0000</ReplyBytes>
<DataItem Name="($70EC) Inverter temperature sensor 1 for freeze frame management" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70ED) MICRO temperature for freeze frame management">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70ED) MICRO temperature for freeze frame management]]></Comment>
<Sent>
<SentBytes>2270ED</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270ED0000</ReplyBytes>
<DataItem Name="($70ED) MICRO temperature for freeze frame management" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70EE)PCB temperature for freeze frame management">
<DossierMaintenabilite/>
<Comment><![CDATA[Read ($70EE)PCB temperature for freeze frame management]]></Comment>
<Sent>
<SentBytes>2270EE</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270EE0000</ReplyBytes>
<DataItem Name="($70EE)PCB temperature for freeze frame management" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.Ratio between square of excitation signal and sum of squares of rotor reslver cos and sine signals">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Ratio between square of excitation signal and sum of squares of rotor reslver cos and sine signals]]></Comment>
<Sent>
<SentBytes>2270F3</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270F30000</ReplyBytes>
<DataItem Name="Ratio between square of excitation signal and sum of squares of rotor reslver cos and sine signals" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70F0) Absolute time since first Ignition">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Absolute time since first Ignition]]></Comment>
<Sent>
<SentBytes>2270F0</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270F00000</ReplyBytes>
<DataItem Name="($70F0) Absolute time since first Ignition" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70F2) Environment temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Environment temperature]]></Comment>
<Sent>
<SentBytes>2270F2</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270F2</ReplyBytes>
<DataItem Name="($70F2) Environment temperature" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7016)Result of the check on CAN with EVC (torque request CLK+torque request CRC+CAN confirmed absent)">
<DossierMaintenabilite/>
<Comment><![CDATA[Request $22 - Vbx_can_emot_tq_sp_nok]]></Comment>
<Sent>
<SentBytes>227016</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62701600</ReplyBytes>
<DataItem Name="($7016)Result of the check on CAN with EVC (torque request CLK+torque request CRC+CAN confirmed absent)" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($70CB)Nvrol error counters.8 bits MSB(double bit errors number).8 bits LSB(simple bit errors number)">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Nvrol error counters. 8 bits MSB (double bit errors number (1_255)). 8 bits LSB (simple bit errors number (1_255)) [Vxx_inv_nvrol_err_cnt]]]></Comment>
<Sent>
<SentBytes>2270CB</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270CB0000</ReplyBytes>
<DataItem Name="($70CB)Nvrol error counters.8 bits MSB(double bit errors number).8 bits LSB(simple bit errors number)" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2000) DIDs supported in range [$2001 - $2020]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$2001 - $2020]]]></Comment>
<Sent>
<SentBytes>222000</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62200000000000</ReplyBytes>
<DataItem Name="($2000) DIDs supported in range [$2001 - $2020]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($2060) DIDs supported in range [$2061 - $2080]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$2061 - $2080]]]></Comment>
<Sent>
<SentBytes>222060</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62206000000000</ReplyBytes>
<DataItem Name="($2060) DIDs supported in range [$2061 - $2080]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7000) DIDs supported in range [$7001 - $7020]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$7001 - $7020]]]></Comment>
<Sent>
<SentBytes>227000</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62700000000000</ReplyBytes>
<DataItem Name="($7000) DIDs supported in range [$7001 - $7020]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7020) DIDs supported in range [$7021 - $7040]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$7021 - $7040]]]></Comment>
<Sent>
<SentBytes>227020</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62702000000000</ReplyBytes>
<DataItem Name="($7020) DIDs supported in range [$7021 - $7040]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7040) DIDs supported in range [$7041 - $7060]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$7041 - $7060]]]></Comment>
<Sent>
<SentBytes>227040</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62704000000000</ReplyBytes>
<DataItem Name="($7040) DIDs supported in range [$7041 - $7060]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7060) DIDs supported in range [$7061 - $7080]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$7061 - $7080]]]></Comment>
<Sent>
<SentBytes>227060</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62706000000000</ReplyBytes>
<DataItem Name="($7060) DIDs supported in range [$7061 - $7080]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($7080) DIDs supported in range [$7081 - $70A0]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$7081 - $70A0]]]></Comment>
<Sent>
<SentBytes>227080</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>62708000000000</ReplyBytes>
<DataItem Name="($7080) DIDs supported in range [$7081 - $70A0]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70A0) DIDs supported in range [$70A1 - $70C0]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$70A1 - $70C0]]]></Comment>
<Sent>
<SentBytes>2270A0</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>6270A000000000</ReplyBytes>
<DataItem Name="($70A0) DIDs supported in range [$70A1 - $70C0]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70C0) DIDs supported in range [$70C1 - $70E0]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$70C1 - $70E0]]]></Comment>
<Sent>
<SentBytes>2270C0</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>6270C000000000</ReplyBytes>
<DataItem Name="($70C0) DIDs supported in range [$70C1 - $70E0]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($70E0) DIDs supported in range [$70E1 - $7100]">
<DossierMaintenabilite/>
<Comment><![CDATA[DIDs supported in range [$70E1 - $7100]]]></Comment>
<Sent>
<SentBytes>2270E0</SentBytes>
</Sent>
<Received MinBytes="7">
<ReplyBytes>6270E000000000</ReplyBytes>
<DataItem Name="($70E0) DIDs supported in range [$70E1 - $7100]" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.($702A) software over voltage protection">
<DossierMaintenabilite/>
<Comment><![CDATA[Vbx_sw_ovp_udc_mem]]></Comment>
<Sent>
<SentBytes>22702A</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702A00</ReplyBytes>
<DataItem Name="($702A) software over voltage protection" Ref="1" FirstByte="4" BitOffset="7"/>
</Received>
</Request>
<Request Name="DataRead.($702C) Distribution type from JB to PEB">
<DossierMaintenabilite/>
<Comment><![CDATA[Vsx_chg_dstb_req]]></Comment>
<Sent>
<SentBytes>22702C</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62702C00</ReplyBytes>
<DataItem Name="($702C) Distribution type from JB to PEB" Ref="1" FirstByte="4" BitOffset="6"/>
</Received>
</Request>
<Request Name="DataRead.($7090) Water temperature">
<DossierMaintenabilite/>
<Comment><![CDATA[Wxx_wtr_temp]]></Comment>
<Sent>
<SentBytes>227090</SentBytes>
</Sent>
<Received MinBytes="4">
<ReplyBytes>62709000</ReplyBytes>
<DataItem Name="($7090) Water temperature" Ref="1" FirstByte="4" BitOffset="1"/>
</Received>
</Request>
<Request Name="DataRead.($70EF) counter giving the nember of times Wsx_cuc_f_dfl is equal to Nsx_i_f_df">
<DossierMaintenabilite/>
<Comment><![CDATA[Sxx_cuc_f_dfl_3_ctr]]></Comment>
<Sent>
<SentBytes>2270EF</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270EF0000</ReplyBytes>
<DataItem Name="($70EF) counter giving the nember of times Wsx_cuc_f_dfl is equal to Nsx_i_f_df" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataWrite.($70EF) counter giving the nember of times Wsx_cuc_f_dfl is equal to Nsx_i_f_df">
<DossierMaintenabilite/>
<ManuelSend/>
<Comment><![CDATA[Sxx_cuc_f_dfl_3_ctr]]></Comment>
<Sent>
<SentBytes>2E70EF0000</SentBytes>
<DataItem Name="($70EF) counter giving the nember of times Wsx_cuc_f_dfl is equal to Nsx_i_f_df" FirstByte="4"/>
</Sent>
<Received MinBytes="3">
<ReplyBytes>6E70EF</ReplyBytes>
</Received>
</Request>
<Request Name="DataRead.($70A2) Vxx_invt_rst_ctx_4">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Vxx_invt_rst_ctx_4]]></Comment>
<Sent>
<SentBytes>2270A2</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270A20000</ReplyBytes>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_rot_temp_dfl_sfty_(bit0)" Ref="1" FirstByte="5" BitOffset="7"/>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vsx_emot_n_dfl_sfty_(bit1)" Ref="1" FirstByte="5" BitOffset="6"/>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_dfl_i_f_low_(bit2)" Ref="1" FirstByte="5" BitOffset="5"/>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_alim_21_mon_(bit3)" Ref="1" FirstByte="5" BitOffset="4"/>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_alim_21_mon_red_(bit4)" Ref="1" FirstByte="5" BitOffset="3"/>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vbx_sply_mon_(bit5)" Ref="1" FirstByte="5" BitOffset="2"/>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Stack Overflow on State_(bit6-7)" Ref="1" FirstByte="5"/>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vtx_TaskMaxDurationIT_A[3]_(bit8-11)" Ref="1" FirstByte="4"/>
<DataItem Name="($70A2) Vxx_invt_rst_ctx_4.($70A2) Vxx_10ms_max_duration_(bit12-15)" Ref="1" FirstByte="4" BitOffset="4"/>
</Received>
</Request>
<Request Name="DataRead.($70F1) Max ratio between the square of excitation sgnl and the sum of squares of rotor reslver cos and sin sgnl">
<DossierMaintenabilite/>
<Comment><![CDATA[Read Max ratio between the square of excitation sgnl and the sun of squares of rotor reslver cos and sin sgnl]]></Comment>
<Sent>
<SentBytes>2270F1</SentBytes>
</Sent>
<Received MinBytes="5">
<ReplyBytes>6270F10000</ReplyBytes>
<DataItem Name="($70F1) Max ratio between the square of excitation sgnl and the sum of squares of rotor reslver cos and sin sgnl" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.VehicleManufacturerECUHardwareNumber_DAI">
<DossierMaintenabilite/>
<Comment><![CDATA[Read VehicleManufacturerECUSoftwareNumber_DAI]]></Comment>
<Sent>
<SentBytes>22F111</SentBytes>
</Sent>
<Received MinBytes="13">
<ReplyBytes>62F11100000000000000000000</ReplyBytes>
<DataItem Name="VehicleManufacturerECUHardwareNumber_DAI" Ref="1" FirstByte="4"/>
</Received>
</Request>
<Request Name="DataRead.VehicleManufacturerECUSoftwareNumber_DAI">
<DossierMaintenabilite/>
<Comment><![CDATA[Read DataRead.VehicleManufacturerECUSoftwareNumber_DAI]]></Comment>
<Sent>
<SentBytes>22F121</SentBytes>
</Sent>
<Received MinBytes="23">
<ReplyBytes>62F1210000000000000000000000000000000000000000</ReplyBytes>
<DataItem Name="VehicleManufacturerECUSoftwareNumber_DAI" Ref="1" FirstByte="4"/>
</Received>
</Request>
</Requests>
<Devices>
<Device Name="+APC" DTC="48">
<Mnemonic>apc</Mnemonic>
<Test Type="98">
</Test>
</Device>
<Device Name="BCM (Body Control Module)" DTC="780">
<Mnemonic>bcm</Mnemonic>
<Test Type="135">
</Test>
</Device>
<Device Name="Boost PWM (between rectifier and inverter modules)" DTC="779">
<Mnemonic>chg_pwm</Mnemonic>
<Test Type="49">
</Test>
</Device>
<Device Name="Charger Controler" DTC="774">
<Mnemonic>jb2</Mnemonic>
<Test Type="135">
</Test>
</Device>
<Device Name="DCDC" DTC="2132">
<Mnemonic>dcdc</Mnemonic>
<Test Type="135">
</Test>
</Device>
<Device Name="DCDC driver" DTC="2130">
<Mnemonic>dcdc_dri</Mnemonic>
<Test Type="150">
</Test>
<Test Type="241">
</Test>
<Test Type="242">
</Test>
<Test Type="73">
</Test>
</Device>
<Device Name="DCDC High voltage side" DTC="2128">
<Mnemonic>dcdc_hv</Mnemonic>
<Test Type="34">
</Test>
<Test Type="33">
</Test>
</Device>
<Device Name="DCDC low voltage side" DTC="2129">
<Mnemonic>dcdc_lv</Mnemonic>
<Test Type="34">
</Test>
<Test Type="33">
</Test>
</Device>
<Device Name="Driver board temperature sensor" DTC="2152">
<Mnemonic>dri_temp</Mnemonic>
<Test Type="41">
</Test>
<Test Type="1">
</Test>
</Device>
<Device Name="ECU monitoring (Safety torque estimation)" DTC="2145">
<Mnemonic>sfty_tq</Mnemonic>
<Test Type="150">
</Test>
<Test Type="98">
</Test>
</Device>
<Device Name="ECU monitoring (Watchdog)" DTC="2144">
<Mnemonic>ecm_mon</Mnemonic>
<Test Type="71">
</Test>
</Device>
<Device Name="Electric engine FAN" DTC="2120">
<Mnemonic>cool_air</Mnemonic>
<Test Type="146">
</Test>
<Test Type="41">
</Test>
<Test Type="150">
</Test>
</Device>
<Device Name="Electric engine phase" DTC="2121">
<Mnemonic>emot_ph</Mnemonic>
<Test Type="98">
</Test>
</Device>
<Device Name="Electric engine temperature" DTC="2119">
<Mnemonic>emot_temp</Mnemonic>
<Test Type="152">
</Test>
</Device>
<Device Name="EVC" DTC="781">
<Mnemonic>evc</Mnemonic>
<Test Type="135">
</Test>
<Test Type="129">
</Test>
</Device>
<Device Name="EVC relays" DTC="782">
<Mnemonic>evc_rly</Mnemonic>
<Test Type="98">
</Test>
</Device>
<Device Name="Excitation" DTC="2080">
<Mnemonic>exct</Mnemonic>
<Test Type="25">
</Test>
<Test Type="98">
</Test>
</Device>
<Device Name="Excitation current sensor" DTC="2081">
<Mnemonic>exct_crt_sens</Mnemonic>
<Test Type="150">
</Test>
<Test Type="243">
</Test>
</Device>
<Device Name="Excitation driver (high arm)" DTC="2096">
<Mnemonic>exct_dri_h</Mnemonic>
<Test Type="1">
</Test>
</Device>
<Device Name="Excitation driver (low arm)" DTC="2097">
<Mnemonic>exct_dri_l</Mnemonic>
<Test Type="1">
</Test>
</Device>
<Device Name="Excitation driver ready" DTC="2098">
<Mnemonic>exct_rdy</Mnemonic>
<Test Type="1">
</Test>
</Device>
<Device Name="Excitation temperature sensor" DTC="2082">
<Mnemonic>exct_temp</Mnemonic>
<Test Type="1">
</Test>
<Test Type="41">
</Test>
</Device>
<Device Name="Hardware over voltage protection" DTC="2055">
<Mnemonic>invt_hard</Mnemonic>
<Test Type="34">
</Test>
</Device>
<Device Name="High voltage network" DTC="2160">
<Mnemonic>hv</Mnemonic>
<Test Type="34">
</Test>
<Test Type="98">
</Test>
<Test Type="36">
</Test>
</Device>
<Device Name="High voltage sensor" DTC="2051">
<Mnemonic>hv_sens</Mnemonic>
<Test Type="150">
</Test>
<Test Type="243">
</Test>
</Device>
<Device Name="Inverter" DTC="2049">
<Mnemonic>invt</Mnemonic>
<Test Type="34">
</Test>
<Test Type="25">
</Test>
</Device>
<Device Name="Inverter auto diagnosis" DTC="2058">
<Mnemonic>invt_auto_dg</Mnemonic>
<Test Type="150">
</Test>
</Device>
<Device Name="Inverter current sensor" DTC="2050">
<Mnemonic>invt_crt_sens</Mnemonic>
<Test Type="150">
</Test>
<Test Type="243">
</Test>
</Device>
<Device Name="Inverter DFLASH memory corruption" DTC="2059">
<Mnemonic>invt_dflash</Mnemonic>
<Test Type="70">
</Test>
</Device>
<Device Name="Inverter driver (high arm)" DTC="2064">
<Mnemonic>invt_dri_h</Mnemonic>
<Test Type="1">
</Test>
</Device>
<Device Name="Inverter driver (low arm)" DTC="2065">
<Mnemonic>invt_dri_l</Mnemonic>
<Test Type="1">
</Test>
</Device>
<Device Name="Inverter driver ready (high arm)" DTC="2066">
<Mnemonic>invt_rdy_h</Mnemonic>
<Test Type="1">
</Test>
</Device>
<Device Name="Inverter driver ready (low arm)" DTC="2067">
<Mnemonic>invt_rdy_l</Mnemonic>
<Test Type="1">
</Test>
</Device>
<Device Name="Inverter non traction safety watch" DTC="2057">
<Mnemonic>non_tract</Mnemonic>
<Test Type="150">
</Test>
</Device>
<Device Name="Inverter phase" DTC="2056">
<Mnemonic>invt_phas</Mnemonic>
<Test Type="19">
</Test>
</Device>
<Device Name="Inverter Reset failure" DTC="2060">
<Mnemonic>invt_rst</Mnemonic>
<Test Type="150">
</Test>
</Device>
<Device Name="Inverter temperature" DTC="2053">
<Mnemonic>invt_temp</Mnemonic>
<Test Type="152">
</Test>
</Device>
<Device Name="Inverter temperature sensor" DTC="2052">
<Mnemonic>invt_temp_1</Mnemonic>
<Test Type="1">
</Test>
<Test Type="41">
</Test>
</Device>
<Device Name="Lithium Battery Controler" DTC="773">
<Mnemonic>lbc</Mnemonic>
<Test Type="135">
</Test>
</Device>
<Device Name="Main controler temperature sensor" DTC="2148">
<Mnemonic>mc_temp</Mnemonic>
<Test Type="1">
</Test>
<Test Type="41">
</Test>
</Device>
<Device Name="PCB controler temperature sensor" DTC="2149">
<Mnemonic>pcb_temp</Mnemonic>
<Test Type="1">
</Test>
<Test Type="41">
</Test>
</Device>
<Device Name="Power supply 2.1" DTC="2151">
<Mnemonic>pws_21</Mnemonic>
<Test Type="28">
</Test>
</Device>
<Device Name="PWM Electric Engine command" DTC="2114">
<Mnemonic>pwm</Mnemonic>
<Test Type="98">
</Test>
</Device>
<Device Name="Rotor position offset learning" DTC="2122">
<Mnemonic>psn_ofs</Mnemonic>
<Test Type="65">
</Test>
</Device>
<Device Name="Rotor position sensor" DTC="2113">
<Mnemonic>emot_psn_sens</Mnemonic>
<Test Type="243">
</Test>
</Device>
<Device Name="Rotor position speed" DTC="2112">
<Mnemonic>emot_n</Mnemonic>
<Test Type="150">
</Test>
<Test Type="243">
</Test>
</Device>
<Device Name="Rotor resistance leaning" DTC="2123">
<Mnemonic>rot_r</Mnemonic>
<Test Type="65">
</Test>
</Device>
<Device Name="Safety rotor temperature estimation" DTC="2115">
<Mnemonic>rot_temp_sfty</Mnemonic>
<Test Type="98">
</Test>
</Device>
<Device Name="SPI communication" DTC="2146">
<Mnemonic>spi</Mnemonic>
<Test Type="150">
</Test>
</Device>
<Device Name="Stator temperature sensor 1" DTC="2117">
<Mnemonic>sttr_temp_1</Mnemonic>
<Test Type="1">
</Test>
<Test Type="41">
</Test>
</Device>
<Device Name="Stator temperature sensor 2" DTC="2118">
<Mnemonic>sttr_temp_2</Mnemonic>
<Test Type="1">
</Test>
<Test Type="41">
</Test>
</Device>
<Device Name="Supply monitoring" DTC="2147">
<Mnemonic>sply_mon</Mnemonic>
<Test Type="150">
</Test>
</Device>
<Device Name="Voltage supply A11" DTC="2176">
<Mnemonic>pws_a11</Mnemonic>
<Test Type="150">
</Test>
</Device>
<Device Name="Water temperature" DTC="2054">
<Mnemonic>wtr_temp</Mnemonic>
<Test Type="41">
</Test>
</Device>
<Device Name="CAN communication with battery" DTC="2312">
<Mnemonic>bms_rn8</Mnemonic>
<Test Type="97" Severity="0">
</Test>
</Device>
<Device Name="Stator temperature sensors" DTC="2602">
<Mnemonic>sttr_temp</Mnemonic>
<Test Type="1">
</Test>
<Test Type="145">
</Test>
</Device>
</Devices>
<ds:Categories xmlns="http://www-diag.renault.com/2002/screens">
<Category Name="ident&amp;Reprog">
<Screen Name="Ident" Color="8355711" WindowState="0" Width="11340" Height="6780">
<Label Text="Homologation Number" Color="16744576" Alignment="0">
<Rectangle Left="360" Top="1080" Height="480" Width="6840"/>
<Font Name="MS Sans Serif" Size=" 12" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Hardware number" Color="16744576" Alignment="0">
<Rectangle Left="315" Top="2400" Height="480" Width="9600"/>
<Font Name="MS Sans Serif" Size=" 12" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Part number" Color="16744576" Alignment="0">
<Rectangle Left="315" Top="3000" Height="480" Width="9600"/>
<Font Name="MS Sans Serif" Size=" 12" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="VIN" Color="16744576" Alignment="0">
<Rectangle Left="360" Top="480" Height="480" Width="9600"/>
<Font Name="MS Sans Serif" Size=" 12" Bold="1" Italic="0" Color="16777215"/>
</Label>
<Display Width="0" Color="16777215" DataName="PartNumber.LowerPart" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="6945" Top="3120" Height="300" Width="1781"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3185" Color="16777215" DataName="DiagnosticIdentificationCode" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="360" Top="4800" Height="300" Width="6600"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3695" Color="16777215" DataName="SupplierNumber.ITG" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="360" Top="2040" Height="300" Width="8400"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16777215" DataName="HardwareNumber.LowerPart" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="6960" Top="2520" Height="300" Width="1796"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3185" Color="16777215" DataName="SoftwareNumber" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="360" Top="3720" Height="300" Width="6600"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3185" Color="16777215" DataName="EditionNumber" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="360" Top="4080" Height="300" Width="6600"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3185" Color="16777215" DataName="CalibrationNumber" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="360" Top="4440" Height="300" Width="6600"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16777215" DataName="PartNumber.BasicPartList" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="5160" Top="3120" Height="300" Width="1781"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16777215" DataName="HardwareNumber.BasicPartList" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="5160" Top="2520" Height="300" Width="1796"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3695" Color="16777215" DataName="ManufacturerIdentificationCode" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="360" Top="1680" Height="300" Width="8400"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16777215" DataName="V.I.N" RequestName="Read Frame VIN">
<Rectangle Left="2280" Top="510" Height="420" Width="5280"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16777215" DataName="ApprovalNumber.BasicPartList" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="3480" Top="1200" Height="300" Width="1440"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="15" Color="16777215" DataName="ApprovalNumber.LowerPart" RequestName="DataRead.History.Reprog.0">
<Rectangle Left="5040" Top="1200" Height="300" Width="1680"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3785" Color="16777215" DataName="($708A) FPGA firmware version Identifier" RequestName="DataRead.($708A) FPGA firmware version Identifier">
<Rectangle Left="360" Top="5520" Height="360" Width="6600"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Ident Daimler" Color="16777215" WindowState="0" Width="9300" Height="5100">
<Label Text="Daimler System Identification" Color="11513775" Alignment="2">
<Rectangle Left="1920" Top="480" Height="467" Width="4762"/>
<Font Name="Palatino Linotype" Size=" 16" Bold="1" Italic="0" Color="16777215"/>
</Label>
<Label Text="::pic:backgrounds\steel1_640x480" Color="255" Alignment="0">
<Rectangle Left="-720" Top="0" Height="5160" Width="10080"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 1" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="1282" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 2" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="1574" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 3" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="1866" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 4" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="2158" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 5" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="2449" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 6" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="2741" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 7" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="3033" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 8" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="3325" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 9" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="3616" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2270" Color="16702669" DataName="Hardware Part Number 10" RequestName="DataRead.Daimler system identification">
<Rectangle Left="1178" Top="3908" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 1" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="1282" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 2" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="1574" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 3" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="1866" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 4" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="2158" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 5" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="2449" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 6" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="2741" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 7" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="3033" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 8" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="3325" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 9" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="3616" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2240" Color="16754342" DataName="Software Part Number 10" RequestName="DataRead.Daimler system identification">
<Rectangle Left="4379" Top="3908" Height="292" Width="2824"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Ident BOOT" Color="10197915" WindowState="0" Width="7860" Height="3540">
<Label Text="BOOT Identification" Color="10197915" Alignment="2">
<Rectangle Left="1200" Top="360" Height="360" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 18" Bold="0" Italic="0" Color="16777215"/>
</Label>
<Label Text="Version" Color="16777215" Alignment="0">
<Rectangle Left="240" Top="1560" Height="300" Width="3120"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="0"/>
</Label>
<Label Text="Soft" Color="16777215" Alignment="0">
<Rectangle Left="240" Top="1200" Height="300" Width="3120"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="0"/>
</Label>
<Send Delay="0" RequestName="StartDiagnosticSession.Programming"/>
<Send Delay="0" RequestName="TesterPresent.WithResponse"/>
<Send Delay="0" RequestName="DataRead.Identification.RenaultR2"/>
<Display Width="0" Color="16772810" DataName="SoftwareNumber" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="3360" Top="1200" Height="300" Width="3480"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16772810" DataName="EditionNumber" RequestName="DataRead.Identification.RenaultR2">
<Rectangle Left="3360" Top="1560" Height="300" Width="3480"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Indication autorisation reprog &amp; lecture/effacm DTC" Color="16777215" WindowState="0" Width="15540" Height="4740">
<Label Text="Interlock plug service débranché" Color="16777215" Alignment="0">
<Rectangle Left="6840" Top="2160" Height="360" Width="4920"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="16711680"/>
</Label>
<Label Text="Conditions de Reprog OK" Color="15724527" Alignment="2">
<Rectangle Left="12600" Top="2160" Height="600" Width="2520"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="32768"/>
</Label>
<Label Text="Rotor mechanical rotation speed" Color="14671839" Alignment="2">
<Rectangle Left="480" Top="1440" Height="240" Width="3531"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="0"/>
</Label>
<Label Text="Condition Diag OK" Color="15724527" Alignment="2">
<Rectangle Left="7200" Top="720" Height="360" Width="2640"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="32000"/>
</Label>
<Label Text="Lecture/Effacement DTC OK" Color="15724527" Alignment="2">
<Rectangle Left="10560" Top="600" Height="600" Width="2640"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="32768"/>
</Label>
<Label Text="::pic:backgrounds\steel1_640x480" Color="255" Alignment="1">
<Rectangle Left="-1200" Top="0" Height="4800" Width="16920"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="1) Lecture/effacement DTC" Color="13619151" Alignment="0">
<Rectangle Left="6360" Top="360" Height="1320" Width="8880"/>
<Font Name="MS Sans Serif" Size=" 12" Bold="1" Italic="0" Color="16777215"/>
</Label>
<Label Text="2) Reprog" Color="13619151" Alignment="0">
<Rectangle Left="6360" Top="1800" Height="1680" Width="8880"/>
<Font Name="MS Sans Serif" Size=" 12" Bold="1" Italic="0" Color="16777215"/>
</Label>
<Label Text="=&gt; Vsx_lbc_ilck_stt ($7031) = 1 (Open) " Color="15724527" Alignment="0">
<Rectangle Left="6840" Top="2400" Height="360" Width="3360"/>
<Font Name="MS Sans Serif" Size=" 9" Bold="1" Italic="0" Color="255"/>
</Label>
<Label Text="Si" Color="14671839" Alignment="2">
<Rectangle Left="120" Top="1440" Height="600" Width="360"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="16711680"/>
</Label>
<Label Text="Vxx_emot_n ($2001) = 0" Color="14671839" Alignment="2">
<Rectangle Left="480" Top="1680" Height="360" Width="3480"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="255"/>
</Label>
<Label Text="::pic:arrows\right_24x24" Color="255" Alignment="0">
<Rectangle Left="6480" Top="720" Height="360" Width="720"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="::pic:arrows\line_right_up_64x64" Color="255" Alignment="0">
<Rectangle Left="5520" Top="840" Height="960" Width="840"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="::pic:arrows\line_left_up_64x64" Color="255" Alignment="0">
<Rectangle Left="5520" Top="1800" Height="960" Width="840"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="::pic:arrows\right_24x24" Color="255" Alignment="0">
<Rectangle Left="11880" Top="2280" Height="360" Width="720"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="::pic:arrows\right_24x24" Color="255" Alignment="0">
<Rectangle Left="9840" Top="720" Height="360" Width="720"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Et" Color="13619151" Alignment="2">
<Rectangle Left="6360" Top="2280" Height="480" Width="480"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="16711680"/>
</Label>
<Display Width="0" Color="15724527" DataName="($7031) Interlock plug service status, from LBC (condition for reprogramming)" RequestName="DataRead.($7031) Interlock plug service status, from LBC (condition for reprogramming)">
<Rectangle Left="10200" Top="2400" Height="360" Width="1560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="15724527" DataName="($2001) Rotor mechanical rotation speed" RequestName="DataRead.($2001) Rotor mechanical rotation speed">
<Rectangle Left="3960" Top="1440" Height="600" Width="1560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Verrou logiciel" Color="12615808" WindowState="0" Width="15420" Height="11700">
<Label Text="Verlog" Color="8355711" Alignment="2">
<Rectangle Left="120" Top="240" Height="2280" Width="9240"/>
<Font Name="MS Sans Serif" Size=" 14" Bold="0" Italic="0" Color="986895"/>
</Label>
<Label Text="Si Etat protégé = 1 alors démarrage impossible" Color="16777215" Alignment="0">
<Rectangle Left="9840" Top="600" Height="240" Width="5040"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="4680" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM in secure mode" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="4920" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to no BCM authorisation" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="5160" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to a CAN network problem with the BCM" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="5400" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="5400" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="4680" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="5160" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Danc ce cas le calculateur est déprotégé et n'interdit pas le démarrage moteur" Color="16762566" Alignment="0">
<Rectangle Left="6360" Top="3120" Height="480" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="986895"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="8640" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM in secure mode" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="8880" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to no BCM authorisation" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="9120" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to a CAN network problem with the BCM" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="9360" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="8640" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="8880" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="9360" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="L'ECM est protégé car il ne reçoit pas les trames de la BCM: l'ECM n'autorise pas le démarrage moteur." Color="11513775" Alignment="0">
<Rectangle Left="6360" Top="4440" Height="480" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="986895"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="3360" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM in secure mode" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="3600" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to no BCM authorisation" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="3840" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to a CAN network problem with the BCM" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="4080" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="4440" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="3360" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="3840" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="4080" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="8400" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="L'ECM est protégé car la BCM ne répond pas correctement: l'ECM n'autorise pas le démarrage moteur." Color="16762566" Alignment="0">
<Rectangle Left="6360" Top="5760" Height="467" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="-&gt; La BCM n'a pas authentifié la clé ou le badge" Color="16762566" Alignment="0">
<Rectangle Left="6360" Top="6227" Height="234" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="-&gt; L'ECM n'est pas monté sur le véhicule sur lequel il a appris le code" Color="16762566" Alignment="0">
<Rectangle Left="6360" Top="6461" Height="379" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="6000" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM in secure mode" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="6240" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to no BCM authorisation" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="6480" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to a CAN network problem with the BCM" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="6720" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="6000" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="6240" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="6480" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="6720" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Imobilizer - Diagnosis availability" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="4440" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="3600" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="5760" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Imobilizer - Diagnosis availability" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="8400" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="4920" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Imobilizer - Diagnosis availability" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="3120" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="3120" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Imobilizer - Diagnosis availability" Color="16762566" Alignment="0">
<Rectangle Left="240" Top="5760" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="16762566" Alignment="0">
<Rectangle Left="5760" Top="9120" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="L'ECM est vierge et protégé car la BCM n'envoie pas la clé secrète: l'ECM n'autorise pas le démarrage moteur." Color="11513775" Alignment="0">
<Rectangle Left="6360" Top="7080" Height="480" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="-&gt; La BCM n'est pas autorisée à envoyer la clé secrète" Color="11513775" Alignment="0">
<Rectangle Left="6360" Top="7560" Height="300" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Imobilizer - Diagnosis availability" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="7080" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="7320" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to BCM in secure mode" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="7560" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to no BCM authorisation" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="7800" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Immobilizer - engine not running due to a CAN network problem with the BCM" Color="11513775" Alignment="0">
<Rectangle Left="240" Top="8040" Height="240" Width="5520"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="7080" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="7320" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 1" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="7560" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="7800" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="= 0" Color="11513775" Alignment="0">
<Rectangle Left="5760" Top="8040" Height="240" Width="480"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="L'ECM est &quot;autoprotégé&quot; et n'autorise pas le démarrage moteur." Color="16762566" Alignment="0">
<Rectangle Left="6360" Top="8400" Height="240" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="-&gt; L'ECM a subit une tentative &quot;d'intrusion&quot; ou a détécté une erreur interne (EEPROM, FLASH...)" Color="16762566" Alignment="0">
<Rectangle Left="6360" Top="8640" Height="480" Width="4680"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Display Width="6545" Color="16777215" DataName="($2070) Immobilizer - diagnosis availability" RequestName="DataRead.($2070) Immobilizer - diagnosis availability">
<Rectangle Left="234" Top="915" Height="261" Width="8761"/>
<Font Name="Tahoma" Size=" 8" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6545" Color="16777215" DataName="($2074) Immobilizer - engine not running due to ECM" RequestName="DataRead.($2074) Immobilizer - engine not running due to ECM">
<Rectangle Left="239" Top="1230" Height="261" Width="8761"/>
<Font Name="Tahoma" Size=" 8" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6545" Color="16777215" DataName="($2075) Immobilizer - engine not running due to BCM in secure mode" RequestName="DataRead.($2075) Immobilizer - engine not running due to BCM in secure mode">
<Rectangle Left="239" Top="1542" Height="261" Width="8761"/>
<Font Name="Tahoma" Size=" 8" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6545" Color="16777215" DataName="($2076) Immobilizer - engine not running due to no BCM authorization" RequestName="DataRead.($2076) Immobilizer - engine not running due to no BCM authorization">
<Rectangle Left="239" Top="1857" Height="261" Width="8761"/>
<Font Name="Tahoma" Size=" 8" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6545" Color="16777215" DataName="($2077) Immobilizer - engine not running due to a CAN network problem with the BCM" RequestName="DataRead.($2077) Immobilizer - engine not running due to a CAN network problem with the BCM">
<Rectangle Left="239" Top="2172" Height="261" Width="8761"/>
<Font Name="Tahoma" Size=" 8" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
</Category>
<Category Name="input&amp;Output">
<Screen Name="Commande actuateurs" Color="16744576" WindowState="0" Width="14820" Height="9060">
<Label Text="Commande actuateurs" Color="4227327" Alignment="2">
<Rectangle Left="3480" Top="240" Height="480" Width="4560"/>
<Font Name="MS Sans Serif" Size=" 18" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Output Temporary Control List :" Color="8454143" Alignment="0">
<Rectangle Left="9600" Top="1800" Height="300" Width="3720"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="1" Italic="0" Color="0"/>
</Label>
<Label Text="LID $41 - PEC Fan" Color="8454143" Alignment="0">
<Rectangle Left="9600" Top="2100" Height="300" Width="3720"/>
<Font Name="MS Sans Serif" Size=" 6" Bold="0" Italic="0" Color="0"/>
</Label>
<Button Text="Start I/O control">
<Rectangle Left="6600" Top="1800" Height="660" Width="2640"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0"/>
<Message Text=""/>
<Send Delay="0" RequestName="StartDiagnosticSession.ExtendedDiagnosticSession"/>
<Send Delay="0" RequestName="Output Control"/>
</Button>
<Input Width="2945" Color="8454143" DataName="Output Temporary Control List" RequestName="Output Control">
<Rectangle Left="480" Top="1800" Height="300" Width="5880"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Input Width="2945" Color="8454143" DataName="Output Control Command" RequestName="Output Control">
<Rectangle Left="480" Top="2160" Height="300" Width="5880"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Input Width="2975" Color="11599792" DataName="Output Control Command" RequestName="Output Control">
<Rectangle Left="480" Top="2760" Height="300" Width="5880"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Display Width="2975" Color="11599792" DataName="Output Control Status" RequestName="Output Control">
<Rectangle Left="480" Top="3240" Height="300" Width="5880"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
</Category>
<Category Name="Start/Stop RoutineByLocalIdentifier ($31/$32)">
<Screen Name="Factory Static Test" Color="16777215" WindowState="0" Width="12660" Height="7860">
<Label Text="Factory Static Test" Color="11599792" Alignment="2">
<Rectangle Left="0" Top="0" Height="2400" Width="10500"/>
<Font Name="MS Sans Serif" Size=" 14" Bold="1" Italic="0" Color="0"/>
</Label>
<Label Text="Read Routine Entry Status" Color="16777215" Alignment="0">
<Rectangle Left="4560" Top="1200" Height="375" Width="3000"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Button Text=" Start Factory Static Test">
<Rectangle Left="600" Top="1200" Height="375" Width="3000"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0"/>
<Message Text=""/>
<Send Delay="0" RequestName="StartDiagnosticSession.ExtendedDiagnosticSession"/>
<Send Delay="0" RequestName="StartRoutineByLocalIdentifier - Factory Static Test"/>
</Button>
<Display Width="0" Color="16777215" DataName="RoutineEntryStatus" RequestName="StartRoutineByLocalIdentifier">
<Rectangle Left="7080" Top="1200" Height="375" Width="2670"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Other Routines" Color="16777215" WindowState="0" Width="14460" Height="9900">
<Label Text="Start/Stop Routine By LID ($31/$32)" Color="15658734" Alignment="2">
<Rectangle Left="0" Top="0" Height="6120" Width="8760"/>
<Font Name="MS Sans Serif" Size=" 14" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Routine Local Identifier Start" Color="11468799" Alignment="0">
<Rectangle Left="150" Top="2700" Height="300" Width="2700"/>
<Font Name="MS Sans Serif" Size=" 8" Bold="1" Italic="0" Color="0"/>
</Label>
<Label Text="LID $07 - Static test" Color="11468799" Alignment="0">
<Rectangle Left="150" Top="3300" Height="300" Width="2700"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="LID $13 - Position sensor learning" Color="11468799" Alignment="0">
<Rectangle Left="150" Top="3000" Height="300" Width="2700"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="LID $21 - Monitool" Color="11468799" Alignment="0">
<Rectangle Left="150" Top="3600" Height="300" Width="2700"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Routine entry status" Color="11468799" Alignment="0">
<Rectangle Left="5760" Top="2670" Height="300" Width="2250"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="1" Italic="0" Color="0"/>
</Label>
<Label Text="LID $02 - Complete and OK" Color="11468799" Alignment="0">
<Rectangle Left="5760" Top="2970" Height="300" Width="2250"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="LID $01 - In progress" Color="11468799" Alignment="0">
<Rectangle Left="5760" Top="3270" Height="300" Width="2250"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="LID $03 - Complete and not OK" Color="11468799" Alignment="0">
<Rectangle Left="5760" Top="3570" Height="300" Width="2250"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Routine entry option" Color="11468799" Alignment="0">
<Rectangle Left="3135" Top="2685" Height="300" Width="2250"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="1" Italic="0" Color="0"/>
</Label>
<Label Text="LID $00 - Start" Color="11468799" Alignment="0">
<Rectangle Left="3135" Top="2985" Height="300" Width="2250"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="LID $01 - Status" Color="11468799" Alignment="0">
<Rectangle Left="3135" Top="3285" Height="300" Width="2250"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="FOR ROTOR POSITION LEARNING (LID 13)" Color="65280" Alignment="2">
<Rectangle Left="720" Top="6480" Height="300" Width="6960"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="- mettre le +APC forcé : Levier de vitesse en N, appuyer plus de 10 secondes sur le bouton Start." Color="16777215" Alignment="0">
<Rectangle Left="720" Top="7680" Height="360" Width="7800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="- réveil du véhicule + APC présent (badge dans le lecteur) : les relais HT sont fermés" Color="16777215" Alignment="0">
<Rectangle Left="720" Top="7320" Height="360" Width="7800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="- laisser le levier de vitesse en position N" Color="16777215" Alignment="0">
<Rectangle Left="720" Top="8040" Height="360" Width="7800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="- lancer la routine : les roues tournent légèrement pendant quelques dizaines de secondes" Color="16777215" Alignment="0">
<Rectangle Left="720" Top="8400" Height="360" Width="7800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="- une fois la procédure terminée, vérifié l'angle appris" Color="16777215" Alignment="0">
<Rectangle Left="720" Top="8760" Height="360" Width="7800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="- endormir le véhicule pour mémoriser la valeur apprise" Color="16777215" Alignment="0">
<Rectangle Left="720" Top="9120" Height="360" Width="7800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="- lever les roues avant du véhicule qui ne doivent pas toucher le sol" Color="16777215" Alignment="0">
<Rectangle Left="720" Top="6960" Height="360" Width="7800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Button Text="Start routine">
<Rectangle Left="5880" Top="1200" Height="750" Width="1920"/>
<Font Name="MS Sans Serif" Size=" 12" Bold="0" Italic="0"/>
<Message Text=""/>
<Send Delay="0" RequestName="StartDiagnosticSession.ExtendedDiagnosticSession"/>
<Send Delay="0" RequestName="StartRoutineByLocalIdentifier"/>
</Button>
<Button Text="Stop routine">
<Rectangle Left="5880" Top="4500" Height="750" Width="1920"/>
<Font Name="MS Sans Serif" Size=" 12" Bold="0" Italic="0"/>
<Message Text=""/>
<Send Delay="0" RequestName="StopRoutineByLocalIdentifier"/>
</Button>
<Input Width="2570" Color="11468799" DataName="RoutineLocalIdentifierStart" RequestName="StartRoutineByLocalIdentifier">
<Rectangle Left="150" Top="1200" Height="300" Width="5520"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Input Width="2570" Color="11599792" DataName="RoutineLocalIdentifierStop" RequestName="StopRoutineByLocalIdentifier">
<Rectangle Left="150" Top="4500" Height="300" Width="5520"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Input Width="2555" Color="11599792" DataName="RoutineExitOption" RequestName="StopRoutineByLocalIdentifier">
<Rectangle Left="150" Top="4950" Height="300" Width="5520"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Display Width="2570" Color="11599792" DataName="RoutineExitStatus" RequestName="StopRoutineByLocalIdentifier">
<Rectangle Left="150" Top="5400" Height="300" Width="5520"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="2570" Color="11468799" DataName="RoutineEntryStatus" RequestName="StartRoutineByLocalIdentifier">
<Rectangle Left="150" Top="2100" Height="300" Width="5520"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Input Width="2585" Color="11468799" DataName="RoutineEntryOption" RequestName="StartRoutineByLocalIdentifier">
<Rectangle Left="150" Top="1650" Height="300" Width="5520"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
</Screen>
</Category>
<Category Name="Functionnal">
<Screen Name="Sensor I/O" Color="16777215" WindowState="0" Width="18660" Height="11580">
<Display Width="4835" Color="16777215" DataName="($7007) Measured stator current on phase U" RequestName="DataRead.($7007) Measured stator current on phase U">
<Rectangle Left="360" Top="1080" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4835" Color="16777215" DataName="($7008) Measured stator current on phase V" RequestName="DataRead.($7008) Measured stator current on phase V">
<Rectangle Left="360" Top="1440" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4835" Color="16777215" DataName="($7009) Measured stator current on phase W" RequestName="DataRead.($7009) Measured stator current on phase W">
<Rectangle Left="360" Top="1800" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4850" Color="16777215" DataName="($7003) Measured rotor current (sensor 1)" RequestName="DataRead.($7003) Measured rotor current (sensor 1)">
<Rectangle Left="360" Top="2520" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4850" Color="16777215" DataName="($7004) Measured rotor current (sensor 2)" RequestName="DataRead.($7004) Measured rotor current (sensor 2)">
<Rectangle Left="360" Top="2880" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4865" Color="16777215" DataName="($700D) MICRO temperature" RequestName="DataRead.($700D) MICRO temperature">
<Rectangle Left="360" Top="3480" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4865" Color="16777215" DataName="($700E) PCB temperature" RequestName="DataRead.($700E) PCB temperature">
<Rectangle Left="360" Top="3840" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4865" Color="16777215" DataName="($700C) Inverter temperature sensor 1" RequestName="DataRead.($700C) Inverter temperature sensor 1">
<Rectangle Left="360" Top="4200" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4865" Color="16777215" DataName="($700B) Excitation temperature" RequestName="DataRead.($700B) Excitation temperature">
<Rectangle Left="360" Top="4560" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4865" Color="16777215" DataName="($708E) Spare signal for driver board temperature" RequestName="DataRead.($708E) Spare signal for driver board temperature">
<Rectangle Left="360" Top="4920" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4880" Color="16777215" DataName="($700F) Stator temperature sensor 1" RequestName="DataRead.($700F) Stator temperature sensor 1">
<Rectangle Left="360" Top="5640" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="4880" Color="16777215" DataName="($7010) Stator temperature sensor 2" RequestName="DataRead.($7010) Stator temperature sensor 2">
<Rectangle Left="360" Top="6000" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3350" Color="16777215" DataName="($2004) Battery voltage sensor" RequestName="DataRead.($2004) Battery voltage sensor">
<Rectangle Left="11656" Top="1200" Height="300" Width="6265"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3345" Color="16777215" DataName="($7006) Wire frame APC state" RequestName="DataRead.($7006) Wire frame APC state">
<Rectangle Left="11656" Top="1800" Height="300" Width="6265"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="3360" Color="16777215" DataName="($708F) Opening relays wire request" RequestName="DataRead.($708F) Opening relays wire request">
<Rectangle Left="11656" Top="2400" Height="300" Width="6265"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6255" Color="16777215" DataName="($2001) Rotor mechanical rotation speed" RequestName="DataRead.($2001) Rotor mechanical rotation speed">
<Rectangle Left="9120" Top="3360" Height="300" Width="9000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6260" Color="16777215" DataName="($7011) Raw rotor position resolver angular position measurement" RequestName="DataRead.($7011) Raw rotor position resolver angular position measurement">
<Rectangle Left="9120" Top="3720" Height="300" Width="9000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6260" Color="16777215" DataName="($7013) Raw rotor position resolver cosine voltage" RequestName="DataRead.($7013) Raw rotor position resolver cosine voltage">
<Rectangle Left="9120" Top="4320" Height="300" Width="9000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6260" Color="16777215" DataName="($7014) Raw rotor position resolver cosine voltage with 25µs delay" RequestName="DataRead.($7014) Raw rotor position resolver cosine voltage with 25µs delay">
<Rectangle Left="9120" Top="4680" Height="300" Width="9000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Traction-Charge" Color="16777215" WindowState="0" Width="15420" Height="11580">
<Display Width="7415" Color="16777215" DataName="($7083) INV Automation State" RequestName="DataRead.($7083) INV Automation State">
<Rectangle Left="1080" Top="840" Height="300" Width="12240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="7415" Color="16777215" DataName="($2003) Torque setpoint from EVC" RequestName="DataRead.($2003) Torque setpoint from EVC">
<Rectangle Left="1080" Top="1440" Height="300" Width="12240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="7415" Color="16777215" DataName="($7038) Rotor copper temperature raw estimation" RequestName="DataRead.($7038) Rotor copper temperature raw estimation">
<Rectangle Left="1080" Top="2040" Height="300" Width="12240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="7415" Color="16777215" DataName="($7088) Rotor copper temperature estimation" RequestName="DataRead.($7088) Rotor copper temperature estimation">
<Rectangle Left="1080" Top="2760" Height="300" Width="12240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="7415" Color="16777215" DataName="($7087) Observer estimation for stack rotor temperature" RequestName="DataRead.($7087) Observer estimation for stack rotor temperature">
<Rectangle Left="1080" Top="3480" Height="300" Width="12240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8015" Color="16777215" DataName="($7039) Combination of inverter, Excitation, PCB, MC and DRI temperatures, so in %" RequestName="DataRead.($7039) Combination of inverter, Excitation, PCB, MC and DRI temperatures, so in %">
<Rectangle Left="1080" Top="4200" Height="300" Width="12240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="7415" Color="16777215" DataName="($703A) Combination of rotor and stator temperatures, so in %" RequestName="DataRead.($703A) Combination of rotor and stator temperatures, so in %">
<Rectangle Left="1080" Top="4920" Height="300" Width="12240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Resistance-Zero angle" Color="16777215" WindowState="0" Width="15420" Height="11700">
<Label Text="ROTOR RESISTANCE" Color="65280" Alignment="2">
<Rectangle Left="4320" Top="480" Height="300" Width="3240"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="1" Italic="0" Color="0"/>
</Label>
<Label Text="ROTOR OFFSET" Color="65280" Alignment="2">
<Rectangle Left="4440" Top="5520" Height="300" Width="3240"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="1" Italic="0" Color="0"/>
</Label>
<Button Text="Write Rotor Resistance">
<Rectangle Left="8160" Top="2640" Height="480" Width="1800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0"/>
<Message Text=""/>
<Send Delay="0" RequestName="StartDiagnosticSession.ExtendedDiagnosticSession"/>
<Send Delay="0" RequestName="DataWrite.($703B) Resistance rotor learning + CRC written by diag tool"/>
</Button>
<Button Text="Write Rotor Position Offset">
<Rectangle Left="8520" Top="7920" Height="480" Width="1800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0"/>
<Message Text=""/>
<Send Delay="0" RequestName="StartDiagnosticSession.ExtendedDiagnosticSession"/>
<Send Delay="0" RequestName="DataWrite.($7037) Rotor position offset learning + CRC written by diag tool"/>
</Button>
<Display Width="6395" Color="16777215" DataName="($7050) Value for reference rotor resistance (for safety monitoring)" RequestName="DataRead.($7050) Value for reference rotor resistance (for safety monitoring)">
<Rectangle Left="1200" Top="1560" Height="480" Width="7920"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="5765" Color="16777215" DataName="($704C) Received rotor reference resistance CRC" RequestName="DataRead.($704C) Received rotor reference resistance CRC">
<Rectangle Left="1200" Top="3960" Height="300" Width="8160"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="5765" Color="16777215" DataName="($704D) Received value for reference rotor resistance" RequestName="DataRead.($704D) Received value for reference rotor resistance">
<Rectangle Left="1200" Top="3600" Height="300" Width="8160"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="5840" Color="16777215" DataName="($701C) Saved rotor position offset.value" RequestName="DataRead.($701C) Saved rotor position offset">
<Rectangle Left="1320" Top="6240" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="5660" Color="16777215" DataName="($704B) Received TETA position offset" RequestName="DataRead.($704B) Received TETA position offset">
<Rectangle Left="1320" Top="8880" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="5660" Color="16777215" DataName="($704A) TETA CRC received" RequestName="DataRead.($704A) TETA CRC received">
<Rectangle Left="1320" Top="9240" Height="300" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Input Width="5880" Color="16777215" DataName="($7037) Rotor position offset learning + CRC written by diag tool.1" RequestName="DataWrite.($7037) Rotor position offset learning + CRC written by diag tool">
<Rectangle Left="1320" Top="7440" Height="360" Width="8040"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Input Width="0" Color="16777215" DataName="($7037) Rotor position offset learning + CRC written by diag tool.2" RequestName="DataWrite.($7037) Rotor position offset learning + CRC written by diag tool">
<Rectangle Left="9600" Top="7440" Height="360" Width="675"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Input Width="6375" Color="16777215" DataName="($703B) Resistance rotor learning + CRC written by diag tool.1" RequestName="DataWrite.($703B) Resistance rotor learning + CRC written by diag tool">
<Rectangle Left="1200" Top="2160" Height="300" Width="7920"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Input Width="15" Color="16777215" DataName="($703B) Resistance rotor learning + CRC written by diag tool.2" RequestName="DataWrite.($703B) Resistance rotor learning + CRC written by diag tool">
<Rectangle Left="9240" Top="2160" Height="300" Width="720"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
<Display Width="15" Color="16777215" DataName="($7021) Saved resistance rotor.CRC" RequestName="DataRead.($7021) Saved resistance rotor">
<Rectangle Left="9240" Top="1200" Height="300" Width="720"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="6395" Color="16777215" DataName="($7021) Saved resistance rotor.value" RequestName="DataRead.($7021) Saved resistance rotor">
<Rectangle Left="1200" Top="1200" Height="300" Width="7920"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16777215" DataName="($701C) Saved rotor position offset.CRC" RequestName="DataRead.($701C) Saved rotor position offset">
<Rectangle Left="9600" Top="6240" Height="300" Width="675"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="5840" Color="16777215" DataName="($701C) Saved rotor position offset.value.physical" RequestName="DataRead.($701C) Saved rotor position offset">
<Rectangle Left="1320" Top="6720" Height="300" Width="7320"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Valeo vector" Color="16777215" WindowState="0" Width="15420" Height="11580">
<Display Width="10550" Color="16777215" DataName="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.4" RequestName="DataRead.($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="240" Height="300" Width="13782"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.3" RequestName="DataRead.($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="540" Height="300" Width="13782"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.2" RequestName="DataRead.($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="840" Height="300" Width="13782"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.1" RequestName="DataRead.($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="1140" Height="300" Width="13782"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem.0" RequestName="DataRead.($7052) Vector of 5 average dcdc temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="1440" Height="300" Width="13782"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.4" RequestName="DataRead.($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="1920" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.3" RequestName="DataRead.($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="2220" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.2" RequestName="DataRead.($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="2520" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.1" RequestName="DataRead.($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="2820" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem.0" RequestName="DataRead.($7053) Vector of 5 average driver board temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="3120" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.4" RequestName="DataRead.($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="3600" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.3" RequestName="DataRead.($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="3900" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.2" RequestName="DataRead.($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="4200" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.1" RequestName="DataRead.($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="4500" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem.0" RequestName="DataRead.($7054) Vector of 5 average excitation temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="4800" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.4" RequestName="DataRead.($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="5280" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.3" RequestName="DataRead.($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="5580" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.2" RequestName="DataRead.($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="5880" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.1" RequestName="DataRead.($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="6180" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem.0" RequestName="DataRead.($7055) Vector of 5 average inverter temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="6480" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.4" RequestName="DataRead.($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="6960" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.3" RequestName="DataRead.($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="7260" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.2" RequestName="DataRead.($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="7560" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.1" RequestName="DataRead.($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="7860" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem.0" RequestName="DataRead.($7056) Vector of 5 average pcb temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="8160" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.4" RequestName="DataRead.($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="8640" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.3" RequestName="DataRead.($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="8940" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.2" RequestName="DataRead.($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="9240" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.1" RequestName="DataRead.($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="9540" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="10550" Color="16777215" DataName="($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem.0" RequestName="DataRead.($7057) Vector of 5 average wtr temperature on 1s in the minute before break event for post mortem">
<Rectangle Left="480" Top="9840" Height="300" Width="13800"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Valeo others" Color="16777215" WindowState="0" Width="15540" Height="11700">
<Display Width="8195" Color="16777215" DataName="($7058) 1s average dcdc temperature on break event for post mortem" RequestName="DataRead.($7058) 1s average dcdc temperature on break event for post mortem">
<Rectangle Left="1200" Top="1200" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7059) 1s average driver board temperature on break event for post mortem" RequestName="DataRead.($7059) 1s average driver board temperature on break event for post mortem">
<Rectangle Left="1200" Top="1680" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($705A) Derating counter for post mortem" RequestName="DataRead.($705A) Derating counter for post mortem">
<Rectangle Left="1200" Top="2160" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($705B) Blocked rotor counter for post mortem" RequestName="DataRead.($705B) Blocked rotor counter for post mortem">
<Rectangle Left="1200" Top="2640" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($705C) Water overheat temperature counter for post mortem" RequestName="DataRead.($705C) Water overheat temperature counter for post mortem">
<Rectangle Left="1200" Top="3120" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($705D) 1s average excitation temperature on break event for post mortem" RequestName="DataRead.($705D) 1s average excitation temperature on break event for post mortem">
<Rectangle Left="1200" Top="3600" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($705E) 1s average inverter temperature on break event for post mortem" RequestName="DataRead.($705E) 1s average inverter temperature on break event for post mortem">
<Rectangle Left="1200" Top="4080" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($705F) 1s average pcb temperature on break event for post mortem" RequestName="DataRead.($705F) 1s average pcb temperature on break event for post mortem">
<Rectangle Left="1200" Top="4560" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7061) Maximum driver board temperature during last derating" RequestName="DataRead.($7061) Maximum driver board temperature during last derating">
<Rectangle Left="1200" Top="5040" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7062) Maximum excitation temperature during last derating" RequestName="DataRead.($7062) Maximum excitation temperature during last derating">
<Rectangle Left="1200" Top="5520" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7063) Maximum inverter temperature during last derating" RequestName="DataRead.($7063) Maximum inverter temperature during last derating">
<Rectangle Left="1200" Top="6000" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7064) Maximum pcb temperature during last derating" RequestName="DataRead.($7064) Maximum pcb temperature during last derating">
<Rectangle Left="1200" Top="6480" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7065) Maximum water temperature during last derating" RequestName="DataRead.($7065) Maximum water temperature during last derating">
<Rectangle Left="1200" Top="6960" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7066) Charge or non zero torque time counter for post mortem analysis" RequestName="DataRead.($7066) Charge or non zero torque time counter for post mortem analysis">
<Rectangle Left="1200" Top="7440" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7067) APC and zero torque time counter for post mortem analysis" RequestName="DataRead.($7067) APC and zero torque time counter for post mortem analysis">
<Rectangle Left="1200" Top="7920" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7068) Software overcurrent protection counter for post mortem analysis" RequestName="DataRead.($7068) Software overcurrent protection counter for post mortem analysis">
<Rectangle Left="1200" Top="8400" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($7069) Hardware (by the fpga) overcurrent protection counter for post mortem analysis" RequestName="DataRead.($7069) Hardware (by the fpga) overcurrent protection counter for post mortem analysis">
<Rectangle Left="1200" Top="8880" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="8195" Color="16777215" DataName="($706A) Hardware (by the fpga) overvoltage protection counter for post mortem analysis" RequestName="DataRead.($706A) Hardware (by the fpga) overvoltage protection counter for post mortem analysis">
<Rectangle Left="1200" Top="9360" Height="300" Width="13560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
<Screen Name="Sensor Type" Color="12566400" WindowState="0" Width="12060" Height="3420">
<Button Text="CONFIG $7051">
<Rectangle Left="9720" Top="1200" Height="480" Width="1800"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="1" Italic="0"/>
<Message Text=""/>
<Send Delay="0" RequestName="StartDiagnosticSession.ExtendedDiagnosticSession"/>
<Send Delay="0" RequestName="DataWrite.($7051) Position sensor type"/>
</Button>
<Display Width="2915" Color="14671839" DataName="($7051) Position sensor type" RequestName="DataRead.($7051) Position sensor type">
<Rectangle Left="240" Top="720" Height="360" Width="6960"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Input Width="0" Color="14671839" DataName="($7051) Position sensor type" RequestName="DataWrite.($7051) Position sensor type">
<Rectangle Left="7560" Top="720" Height="360" Width="3960"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Input>
</Screen>
<Screen Name="Apprentissage position Rotor" Color="12566463" WindowState="0" Width="12540" Height="9300">
<Label Text="&lt; 70% (Cxx_temp_rot_max_on)" Color="15724527" Alignment="0">
<Rectangle Left="7920" Top="960" Height="360" Width="3120"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text=" Vitesse nulle (voir l'écran &quot;Ident &amp; Reprog&quot; / &quot;Indications autorisation reprog &amp; lecture/effacm DTC&quot;)" Color="15724527" Alignment="0">
<Rectangle Left="480" Top="3120" Height="360" Width="10560"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text=" Relais HT fermés =&gt; nécessité +APC et Battery voltage sensor (V) &gt; 60V*" Color="16777215" Alignment="0">
<Rectangle Left="240" Top="3480" Height="1200" Width="12000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Vérification du lancement de l'apprentissage:" Color="15724527" Alignment="0">
<Rectangle Left="7440" Top="6960" Height="360" Width="3960"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="" Color="15724527" Alignment="0">
<Rectangle Left="240" Top="6360" Height="960" Width="12000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Conditions:" Color="16771515" Alignment="0">
<Rectangle Left="120" Top="120" Height="5880" Width="12240"/>
<Font Name="Arial" Size=" 14" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Conséquence:" Color="16756952" Alignment="0">
<Rectangle Left="120" Top="6000" Height="1560" Width="12240"/>
<Font Name="Arial" Size=" 14" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="/!\ : Besoin d'avoir appris la résistance rotor (sinon, Vxx_mot_norm_temp invalide) =&gt; Vérifier DID $7050" Color="16777215" Alignment="0">
<Rectangle Left="240" Top="1320" Height="960" Width="12000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="255"/>
</Label>
<Label Text="" Color="15724527" Alignment="0">
<Rectangle Left="240" Top="480" Height="840" Width="12000"/>
<Font Name="Arial Black" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="" Color="15724527" Alignment="0">
<Rectangle Left="240" Top="2280" Height="1200" Width="12000"/>
<Font Name="MS Sans Serif" Size=" 8.25" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="*Vxx_udc ($2004)" Color="16777215" Alignment="2">
<Rectangle Left="3000" Top="3840" Height="240" Width="2160"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="/!\ : Les relais doivent etre fermés ; si relais ouvert, la décharge active fait tomber la tension udc en dessous de 60V" Color="16777215" Alignment="0">
<Rectangle Left="240" Top="4320" Height="360" Width="11160"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="255"/>
</Label>
<Label Text="= 4: Rotor Position Learning" Color="15724527" Alignment="0">
<Rectangle Left="8040" Top="6600" Height="360" Width="3000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="Vxx_mot_norm_temp ($703A) " Color="15724527" Alignment="2">
<Rectangle Left="2280" Top="960" Height="300" Width="3000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="Combination of rotor and stator temperatures, so in % :" Color="15724527" Alignment="0">
<Rectangle Left="600" Top="600" Height="300" Width="5520"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Sxx_rot_r_ref_sfty ($7050)" Color="16777215" Alignment="2">
<Rectangle Left="2640" Top="1920" Height="300" Width="2640"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="Value for reference rotor resistance (for safety monitoring) (Ohm) :" Color="16777215" Alignment="0">
<Rectangle Left="600" Top="1560" Height="300" Width="8400"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Rotor mechanical rotation speed :" Color="15724527" Alignment="0">
<Rectangle Left="600" Top="2400" Height="300" Width="4920"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="Vxx_emot_n ($2001)" Color="15724527" Alignment="2">
<Rectangle Left="2640" Top="2760" Height="300" Width="2520"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="= 0" Color="15724527" Alignment="0">
<Rectangle Left="8040" Top="2760" Height="300" Width="600"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="&gt; 60V" Color="16777215" Alignment="0">
<Rectangle Left="8040" Top="3840" Height="300" Width="600"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="Roues motrices libres de tourner :" Color="15724527" Alignment="0">
<Rectangle Left="240" Top="4680" Height="1200" Width="12000"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Label Text="1 - Neutre engagé (pas de flag)" Color="15724527" Alignment="0">
<Rectangle Left="720" Top="5040" Height="240" Width="3960"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="2 - Frein à main desserré (pas de flag)" Color="15724527" Alignment="0">
<Rectangle Left="720" Top="5280" Height="240" Width="3960"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="3 - Roues motrices hors sol" Color="15724527" Alignment="0">
<Rectangle Left="720" Top="5520" Height="240" Width="3960"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="Vsx_invt_stt ($7083)" Color="15724527" Alignment="0">
<Rectangle Left="3240" Top="6600" Height="300" Width="1920"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="16711680"/>
</Label>
<Label Text="INV Automation State :" Color="15724527" Alignment="0">
<Rectangle Left="600" Top="6480" Height="300" Width="3120"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Label>
<Display Width="0" Color="15724527" DataName="($703A) Combination of rotor and stator temperatures, so in %" RequestName="DataRead.($703A) Combination of rotor and stator temperatures, so in %">
<Rectangle Left="5160" Top="960" Height="300" Width="2640"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16777215" DataName="($7050) Value for reference rotor resistance (for safety monitoring)" RequestName="DataRead.($7050) Value for reference rotor resistance (for safety monitoring)">
<Rectangle Left="5160" Top="1920" Height="300" Width="2760"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="15724527" DataName="($2001) Rotor mechanical rotation speed" RequestName="DataRead.($2001) Rotor mechanical rotation speed">
<Rectangle Left="5160" Top="2760" Height="300" Width="2760"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="16777215" DataName="($2004) Battery voltage sensor" RequestName="DataRead.($2004) Battery voltage sensor">
<Rectangle Left="5160" Top="3840" Height="300" Width="2760"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
<Display Width="0" Color="15724527" DataName="($7083) INV Automation State" RequestName="DataRead.($7083) INV Automation State">
<Rectangle Left="5280" Top="6600" Height="300" Width="2640"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
</Category>
<Category Name="Conditions for mesures Ratio capteur">
<Screen Name="Conditions for mesures Ratio capteur" Color="16777215" WindowState="0" Width="15180" Height="8220">
<Label Text="Conditions for mesures Ratio capteur" Color="16777215" Alignment="0">
<Rectangle Left="4200" Top="120" Height="300" Width="6720"/>
<Font Name="MS Sans Serif" Size=" 10" Bold="1" Italic="0" Color="0"/>
</Label>
<Display Width="3905" Color="16777215" DataName="($700F) Stator temperature sensor 1" RequestName="DataRead.($700F) Stator temperature sensor 1">
<Rectangle Left="240" Top="960" Height="300" Width="6240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
<Threshold Value="-40" Color="255"/>
<Threshold Value=" 9.9" Color="65280"/>
<Threshold Value=" 25" Color="255"/>
</Display>
<Display Width="3905" Color="16777215" DataName="($7010) Stator temperature sensor 2" RequestName="DataRead.($7010) Stator temperature sensor 2">
<Rectangle Left="240" Top="1320" Height="300" Width="6240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
<Threshold Value="-40" Color="255"/>
<Threshold Value=" 9.9" Color="65280"/>
<Threshold Value=" 25" Color="255"/>
</Display>
<Display Width="3905" Color="16777215" DataName="($7083) INV Automation State" RequestName="DataRead.($7083) INV Automation State">
<Rectangle Left="240" Top="1680" Height="300" Width="6240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
<Threshold Value=" 4" Color="65280"/>
</Display>
<Display Width="3905" Color="16777215" DataName="($70F2) Environment temperature" RequestName="DataRead.($70F2) Environment temperature">
<Rectangle Left="240" Top="2040" Height="300" Width="6240"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
<Threshold Value="-40" Color="255"/>
<Threshold Value=" 9.9" Color="65280"/>
<Threshold Value=" 25" Color="255"/>
</Display>
<Display Width="9755" Color="16777215" DataName="($70F1) Max ratio between the square of excitation sgnl and the sum of squares of rotor reslver cos and sin sgnl" RequestName="DataRead.($70F1) Max ratio between the square of excitation sgnl and the sum of squares of rotor reslver cos and sin sgnl">
<Rectangle Left="240" Top="2400" Height="300" Width="11760"/>
<Font Name="Arial" Size=" 10" Bold="0" Italic="0" Color="0"/>
</Display>
</Screen>
</Category>
</ds:Categories>
</ddt:Target>
</xml>