Original project changes: Add commonly used power consumption units to Metrics

This commit is contained in:
Carsten Schmiemann 2022-11-18 23:26:11 +01:00
parent c761ec774c
commit 901371a989

View file

@ -1504,6 +1504,9 @@ const char* OvmsMetricUnitLabel(metric_unit_t units)
case Percentage: return "%";
case WattHoursPK: return "Wh/km";
case WattHoursPM: return "Wh/mi";
case kWhP100K: return "kWh/100km";
case KPkWh: return "km/kWh";
case MPkWh: return "mi/kWh";
case Nm: return "Nm";
default: return "";
}
@ -1573,15 +1576,48 @@ int UnitConvert(metric_unit_t from, metric_unit_t to, int value)
switch (to)
{
case WattHoursPM: return pkm_to_pmi(value);
case kWhP100K: return value / 10;
case KPkWh: return value ? static_cast<int>(1000.0 / value) : 0;
case MPkWh: return value ? static_cast<int>(km_to_mi(1000.0 / value)) : 0;
default: break;
}
case WattHoursPM:
switch (to)
{
case WattHoursPK: return pmi_to_pkm(value);
case kWhP100K: return pmi_to_pkm(value) / 10;
case KPkWh: return value ? static_cast<int>(mi_to_km(1000.0 / value)) : 0;
case MPkWh: return value ? static_cast<int>(1000.0 / value) : 0;
default: break;
}
break;
case kWhP100K:
switch (to)
{
case WattHoursPM: return pkm_to_pmi(value * 10);
case WattHoursPK: return value * 10;
case KPkWh: return value ? static_cast<int>(100.0 / value) : 0;
case MPkWh: return value ? static_cast<int>(km_to_mi(100.0 / value)) : 0;
default: break;
}
case KPkWh:
switch (to)
{
case WattHoursPM: return value ? static_cast<int>(1000.0 / km_to_mi(float(value))) : 0;
case WattHoursPK: return value ? static_cast<int>(1/(1000.0 * value)) : 0;
case kWhP100K: return value ? static_cast<int>(100.0/value) : 0;
case MPkWh: return km_to_mi(value);
default: break;
}
case MPkWh:
switch (to)
{
case WattHoursPM: return value ? 1000/value : 0;
case WattHoursPK: return value ? static_cast<int>(1000 / mi_to_km(float(value))) : 0;
case kWhP100K: return value ? static_cast<int>(100.0/mi_to_km(float(value))) : 0;
case KPkWh: return mi_to_km(value);
default: break;
}
case Celcius:
if (to == Fahrenheit) return ((value*9)/5) + 32;
break;
@ -1632,10 +1668,10 @@ int UnitConvert(metric_unit_t from, metric_unit_t to, int value)
if (to == Kph) return mi_to_km(value);
break;
case dbm:
if (to == sq) return (value <= -51)?((value + 113)/2):0;
if (to == sq) return (value <= -51) ? ((value + 113)/2) : 0;
break;
case sq:
if (to == dbm) return (value <= 31)?(-113 + (value*2)):0;
if (to == dbm) return (value <= 31) ? (-113 + (value*2)) : 0;
break;
default:
return value;
@ -1707,15 +1743,30 @@ float UnitConvert(metric_unit_t from, metric_unit_t to, float value)
switch (to)
{
case WattHoursPM: return pkm_to_pmi(value);
case kWhP100K: return value / 10;
case KPkWh: return value ? 1000.0 / value : 0;
case MPkWh: return value ? (km_to_mi(1000.0 / value)) : 0;
default: break;
}
case WattHoursPM:
switch (to)
{
case WattHoursPK: return pmi_to_pkm(value);
case kWhP100K: return pmi_to_pkm(value) / 10;
case KPkWh: return value ? (mi_to_km(1000.0 / value)) : 0;
case MPkWh: return value ? (1000.0 / value) : 0;
default: break;
}
break;
case kWhP100K:
switch (to)
{
case WattHoursPM: return pkm_to_pmi(value * 10);
case WattHoursPK: return value * 10;
case KPkWh: return value ? (100.0 / value) : 0;
case MPkWh: return value ? km_to_mi(100.0 / value) : 0;
default: break;
}
case Celcius:
if (to == Fahrenheit) return ((value*9)/5) + 32;
break;
@ -1753,10 +1804,10 @@ float UnitConvert(metric_unit_t from, metric_unit_t to, float value)
if (to == Kph) return mi_to_km(value);
break;
case dbm:
if (to == sq) return int((value <= -51)?((value + 113)/2):0);
if (to == sq) return int((value <= -51) ? ((value + 113)/2) : 0);
break;
case sq:
if (to == dbm) return int((value <= 31)?(-113 + (value*2)):0);
if (to == dbm) return int((value <= 31) ? (-113 + (value*2)) : 0);
break;
default:
return value;