Add more pids from hvac
This commit is contained in:
parent
01df5e29bb
commit
1475aacf45
|
@ -101,7 +101,11 @@ static const OvmsVehicle::poll_pid_t renault_zoe_polls[] = {
|
|||
{ 0x18dadff1, 0x18daf1df, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x2004, { 0, 60, 3, 60 }, 0, ISOTP_EXTFRAME }, // Battery voltage sense
|
||||
{ 0x18dadff1, 0x18daf1df, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x7049, { 0, 60, 3, 60 }, 0, ISOTP_EXTFRAME }, // Current voltage sense
|
||||
|
||||
|
||||
//{ 0x744, 0x764, VEHICLE_POLL_TYPE_OBDIISESSION, SESSION_EXTDIAG, { 60, 60, 60, 60 }, 0, ISOTP_EXTADR }, // OBD Extended Diagnostic Session
|
||||
{ 0x744, 0x764, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x4361, { 0, 3, 10, 10 }, 0, ISOTP_EXTADR }, // Cabin temp
|
||||
{ 0x744, 0x764, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x4360, { 0, 3, 10, 10 }, 0, ISOTP_EXTADR }, // Cabin setpoint
|
||||
{ 0x744, 0x764, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x436B, { 0, 3, 10, 10 }, 0, ISOTP_EXTADR }, // Cabin FAN speed
|
||||
{ 0x744, 0x764, VEHICLE_POLL_TYPE_OBDIIEXTENDED, 0x43D8, { 0, 3, 10, 10 }, 0, ISOTP_EXTADR }, // Compressor speed
|
||||
POLL_LIST_END
|
||||
};
|
||||
|
||||
|
@ -151,6 +155,7 @@ OvmsVehicleRenaultZoePh2::OvmsVehicleRenaultZoePh2() {
|
|||
mt_inv_hv_voltage = MyMetrics.InitFloat("zph2.m.inverter.voltage", SM_STALE_MID, 0, Volts);
|
||||
mt_inv_hv_current = MyMetrics.InitFloat("zph2.m.inverter.current", SM_STALE_MID, 0, Amps);
|
||||
mt_bat_max_charge_power = MyMetrics.InitFloat("zph2.b.max.charge.power", SM_STALE_MID, 0, kW);
|
||||
mt_hvac_compressor_speed = MyMetrics.InitFloat("zph2.h.compressor.speed", SM_STALE_MID, 0);
|
||||
|
||||
// init commands:
|
||||
cmd_zoe = MyCommandApp.RegisterCommand("zoe-ph2", "Renault Zoe Ph2");
|
||||
|
@ -234,9 +239,9 @@ void OvmsVehicleRenaultZoePh2::IncomingPollReply(canbus* bus, uint16_t type, uin
|
|||
case 0x18daf1db:
|
||||
IncomingLBC(type, pid, rxbuf.data(), rxbuf.size());
|
||||
break;
|
||||
// ****** UCH *****
|
||||
case 0x765:
|
||||
IncomingUCH(type, pid, rxbuf.data(), rxbuf.size());
|
||||
// ****** HVAC *****
|
||||
case 0x764:
|
||||
IncomingHVAC(type, pid, rxbuf.data(), rxbuf.size());
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
@ -518,18 +523,28 @@ void OvmsVehicleRenaultZoePh2::IncomingLBC(uint16_t type, uint16_t pid, const ch
|
|||
}
|
||||
|
||||
/**
|
||||
* Handle incoming polls from the UCH Computer
|
||||
* Handle incoming polls from the ClimBox HVAC controller
|
||||
*/
|
||||
void OvmsVehicleRenaultZoePh2::IncomingUCH(uint16_t type, uint16_t pid, const char* data, uint16_t len) {
|
||||
void OvmsVehicleRenaultZoePh2::IncomingHVAC(uint16_t type, uint16_t pid, const char* data, uint16_t len) {
|
||||
switch (pid) {
|
||||
case 0x4B7C: {
|
||||
// Todo
|
||||
// //+"7bc,28,39,1,4094,0,N·m,4B7C,624B7C,ff,Electric brake wheels torque request\n" // Brake Torque
|
||||
case 0x4361: { //Cabin temperature
|
||||
StandardMetrics.ms_v_env_cabintemp->SetValue(float(CAN_UINT(0) - 40), Celcius);
|
||||
ESP_LOGD(TAG, "4361 HVAC ms_v_env_cabintemp: %d", (CAN_UINT(0) - 40));
|
||||
break;
|
||||
}
|
||||
case 0x4B7D: {
|
||||
//"7bc,28,39,1,4094,0,N·m,4B7D,624B7D,ff,Total Hydraulic brake wheels torque request\n"
|
||||
//m_v_hydraulic_brake_power->SetValue(float(CAN_12NIBL(28) -4094)*StdMetrics.ms_v_pos_speed->AsFloat()/3.6/1.28*2*3.141 );
|
||||
case 0x4360: { //Cabin setpoint
|
||||
StandardMetrics.ms_v_env_cabinsetpoint->SetValue(float(((CAN_UINT(0) + 32) / 2)), Celcius);
|
||||
ESP_LOGD(TAG, "4360 HVAC ms_v_env_cabinsetpoint: %d", (CAN_UINT(0) + 32) / 2);
|
||||
break;
|
||||
}
|
||||
case 0x436B: { //Cabin FAN speed
|
||||
StandardMetrics.ms_v_env_cabinfan->SetValue(float(CAN_UINT(0)), Percentage);
|
||||
ESP_LOGD(TAG, "436B HVAC ms_v_env_cabinfan: %d", CAN_UINT(0));
|
||||
break;
|
||||
}
|
||||
case 0x43D8: { //Compressor speed
|
||||
mt_hvac_compressor_speed->SetValue(float(CAN_UINT(0)));
|
||||
ESP_LOGD(TAG, "43D8 HVAC mt_hvac_compressor_speed: %d", CAN_UINT(0));
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
|
|
@ -83,7 +83,7 @@ class OvmsVehicleRenaultZoePh2 : public OvmsVehicle {
|
|||
void IncomingLBC(uint16_t type, uint16_t pid, const char* data, uint16_t len);
|
||||
void IncomingUCH(uint16_t type, uint16_t pid, const char* data, uint16_t len);
|
||||
void IncomingPEB(uint16_t type, uint16_t pid, const char* data, uint16_t len);
|
||||
void IncomingUCC(uint16_t type, uint16_t pid, const char* data, uint16_t len);
|
||||
void IncomingHVAC(uint16_t type, uint16_t pid, const char* data, uint16_t len);
|
||||
void car_on(bool isOn);
|
||||
virtual void Ticker1(uint32_t ticker);
|
||||
virtual void Ticker10(uint32_t ticker);
|
||||
|
@ -108,7 +108,8 @@ class OvmsVehicleRenaultZoePh2 : public OvmsVehicle {
|
|||
OvmsMetricFloat *mt_inv_hv_voltage; //Battery voltage sense
|
||||
OvmsMetricFloat *mt_inv_hv_current; //Battery current sense
|
||||
OvmsMetricFloat *mt_bat_max_charge_power; //Battery max charge power
|
||||
|
||||
OvmsMetricFloat *mt_hvac_compressor_speed; //Compressor speed
|
||||
|
||||
public:
|
||||
void WebInit();
|
||||
void WebDeInit();
|
||||
|
|
Loading…