OVMS3/Reference/ZOE_Ph2/WCGS_Tests.csv

98 lines
2.8 KiB
Text
Raw Normal View History

2022-04-10 18:32:02 +00:00
00,Device and failure type ODB codding
01,General Electrical Failure
02,General signal failure
03,FM / PWM Failures
04,System Internal Failures
05,System Programming Failures
06,Algorithm Based Failures
07,Mechanical Failures
08,Bus Signal / Message Failures
09,Component Failures
11,circuit short to ground
12,circuit short to battery
13,circuit open
14,circuit short to ground or open
15,circuit short to battery or open
16,circuit voltage below threshold
17,circuit voltage above threshold
18,circuit current below threshold
19,circuit current above threshold
1A,circuit resistance below threshold
1B,circuit resistance above threshold
1C,circuit voltage out of range
1D,circuit current out of range
1E,circuit resistance out of range
1F,circuit intermittent
21,signal amplitude < minimum
22,signal amplitude > maximum
23,signal stuck low
24,signal stuck high
25,signal shape / waveform failure
26,signal rate of change below threshold
27,signal rate of change above threshold
28,signal level out of range/zero adjustment failure
29,signal signal invalid
2F,signal erratic
31,no signal
32,signal low time < minimum
33,signal low time > maximum
34,signal high time < minimum
35,signal high time > maximum
36,signal frequency too low
37,signal frequency too high
38,signal frequency incorrect
39,incorrect has too few pulses
3A,incorrect has too many pulses
41,general checksum failure
42,general memory failure
43,special memory failure
44,data memory failure
45,program memory failure
46,calibration / parameter memory failure
47,watchdog / safety µC failure
48,supervision software failure
49,internal electronic failure
4A,incorrect component installed
4B,over temperature
51,not programmed
52,not activated
53,deactivated
54,missing calibration
55,not configured
61,signal calculation failure
62,signal compare failure
63,circuit / component protection time-out
64,signal plausibility failure
65,signal has too few transitions / events
66,signal has too many transitions / events
67,signal incorrect after event
68,event information
71,actuator stuck
72,actuator stuck open
73,actuator stuck closed
74,actuator slipping
75,emergency position not reachable
76,wrong mounting position
77,commanded position not reachable
78,alignment or adjustment incorrect
79,mechanical linkage failure
7A,fluid leak or seal failure
7B,low fluid level
81,invalid serial data received
82,alive / sequence counter incorrect / not updated
83,value of signal protection calculation incorrect
84,signal below allowable range
85,signal above allowable range
86,signal invalid
87,missing message
88,bus off
8F,erratic
91,parametric
92,performance or incorrect operation
93,no operation
94,unexpected operation
95,incorrect assembly
96,component internal failure
97,Component | system operation obstructed or blocked
98,component or system over temperature