OVMS3/Reference/ZOE/TDB_Tests.csv

98 lines
2.8 KiB
Plaintext
Raw Normal View History

2022-04-10 18:32:02 +00:00
47,watchdog / safety µC failure
76,wrong mounting position
83,value of signal protection calculation incorrect
05,System Programming Failures
04,System Internal Failures
48,supervision software failure
43,special memory failure
23,signal stuck low
24,signal stuck high
29,signal signal invalid
25,signal shape / waveform failure
26,signal rate of change below threshold
27,signal rate of change above threshold
64,signal plausibility failure
33,signal low time > maximum
32,signal low time < minimum
86,signal invalid
67,signal incorrect after event
35,signal high time > maximum
34,signal high time < minimum
66,signal has too many transitions / events
65,signal has too few transitions / events
36,signal frequency too low
37,signal frequency too high
38,signal frequency incorrect
2F,signal erratic
62,signal compare failure
61,signal calculation failure
28,signal bias level out of range / 0 adjust failure
84,signal below allowable range
22,signal amplitude > maximum
21,signal amplitude < minimum
85,signal above allowable range
45,program memory failure
92,performance or incorrect operation
91,parametric
4B,over temperature
51,not programmed
55,not configured
52,not activated
31,no signal
93,no operation
87,missing message
54,missing calibration
79,mechanical linkage failure
07,Mechanical Failures
7B,low fluid level
81,invalid serial data received
49,internal electronic failure
3A,incorrect has too many pulses
39,incorrect has too few pulses
4A,incorrect component installed
94,unexpected operation
02,General signal failure
42,general memory failure
01,General Electrical Failure
41,general checksum failure
03,FM (Frequency Modulated) / PWM Failures
7A,fluid leak or seal failure
68,event information
8F,erratic
75,emergency position not reachable
00,Device and failure type ODB codding
53,deactivated
44,data memory failure
95,incorrect assembly
97,Component or system operation obstructed or blocke
96,component internal failure
09,Component Failures
77,commanded position not reachable
1C,circuit voltage out of range
16,circuit voltage below threshold
17,circuit voltage above threshold
14,circuit short to ground or open
11,circuit short to ground
15,circuit short to battery or open
12,circuit short to battery
1E,circuit resistance out of range
1A,circuit resistance below threshold
1B,circuit resistance above threshold
13,circuit open
1F,circuit intermittent
1D,circuit current out of range
18,circuit current below threshold
19,circuit current above threshold
63,circuit / component protection time-out
46,calibration / parameter memory failure
08,Bus Signal / Message Failures
88,bus off
82,alive / sequence counter incorrect / not updated
78,alignment or adjustment incorrect
06,Algorithm Based Failures
72,actuator stuck open
73,actuator stuck closed
71,actuator stuck
74,actuator slipping
98,component or system over temperature