How to detect and identify CANopen nodes
|
||
|
================================================================================
|
||
|
|
||
|
So you've got a CAN bus with some devices, but you don't know which of them
|
||
|
speaks "CANopen", if any? The OVMS v3 will help you to detect them and open
|
||
|
their CANs ;)
|
||
|
|
||
|
|
||
|
Before you begin
|
||
|
----------------
|
||
|
|
||
|
…you need to activate the CAN bus(es) you're going to use. As a CANopen master
|
||
|
needs to write to the network, you need to start the interfaces in active mode,
|
||
|
i.e. …::
|
||
|
|
||
|
OVMS# can can1 start active 500000
|
||
|
OVMS# can can2 start active 125000
|
||
|
|
||
|
… and then start the CANopen master for the bus(es), i.e.::
|
||
|
|
||
|
OVMS# copen can1 start
|
||
|
OVMS# copen can2 start
|
||
|
|
||
|
|
||
|
Detecting CANopen nodes
|
||
|
-----------------------
|
||
|
|
||
|
The "open" in "CANopen" means any implementation can decide how much of the
|
||
|
standard it implements. There are some few mandatory features though, a CANopen
|
||
|
slave has to implement, if it wants to comply with the standard.
|
||
|
|
||
|
The mandatory features helping to detect and identify CANopen nodes on a CAN
|
||
|
bus are:
|
||
|
|
||
|
- NMT (network management), especially RESET and PREOP
|
||
|
- NMT bootup event messages
|
||
|
- Standard SDO access in pre-operational mode
|
||
|
|
||
|
If you've got CANopen nodes on a bus, even silent ones, issuing ``copen … nmt reset``
|
||
|
will tell all of them to reboot, and as bootup messages are mandatory,
|
||
|
you will see them in the OVMS log output like this::
|
||
|
|
||
|
I (162904) canopen: can1 node 1 new state: Booting
|
||
|
|
||
|
The OVMS CANopen master continously monitors the network for NMT and EMCY
|
||
|
messages. After bootup of all nodes, you can get a list of all nodes that have
|
||
|
been detected by issuing ``metrics list co.``::
|
||
|
|
||
|
OVMS# metrics list co.
|
||
|
co.can1.nd1.emcy.code
|
||
|
co.can1.nd1.emcy.type
|
||
|
co.can1.nd1.state Operational
|
||
|
|
||
|
.. note:: if you request a reset, nodes may decide to boot into pre-operational
|
||
|
state. That may produce some error messages. Don't worry, you can resolve this
|
||
|
anytime by issuing ``copen … nmt start``.
|
||
|
|
||
|
|
||
|
Identifying CANopen nodes
|
||
|
-------------------------
|
||
|
|
||
|
In pre-operational state, a CANopen node must be accessible at the CANopen
|
||
|
default IDs. That means if the node supports SDO access, we can query some
|
||
|
standard attributes from it.
|
||
|
|
||
|
That's what ``copen … info`` and ``copen … scan`` do:
|
||
|
|
||
|
- ``copen … info`` queries the standard device attributes from a specific node,
|
||
|
- ``copen … scan`` queries all 127 node IDs.
|
||
|
|
||
|
.. caution:: There may be non-CANopen devices on the bus producing regular data
|
||
|
frames at CANopen response IDs and/or reading and possibly misinterpreting
|
||
|
CANopen requests sent to node IDs not planned by the manufacturer. Chances are
|
||
|
low this triggers problems, but you should be ready to switch off the vehicle
|
||
|
when doing a scan -- just in case.
|
||
|
|
||
|
A complete scan takes about 20 seconds. A typical scan could look like this::
|
||
|
|
||
|
OVMS# level debug canopen
|
||
|
OVMS# copen can1 scan
|
||
|
Scan #1-127...
|
||
|
Node #1:
|
||
|
Device type: 0x00000000
|
||
|
Error state: 0x00
|
||
|
Vendor ID: 0x0000001e
|
||
|
Product: 0x0712302d
|
||
|
Revision: 0x00010019
|
||
|
S/N: 0x47c5…………
|
||
|
Device name: Gen4 (Renault Twizy)11 November 2011 12
|
||
|
HW version: 0x00000003
|
||
|
SW version: 0712.0001
|
||
|
Node #23: SDO access failed
|
||
|
Node #25: SDO access failed
|
||
|
Node #27: SDO access failed
|
||
|
Node #30: SDO access failed
|
||
|
Node #87: SDO access failed
|
||
|
Done.
|
||
|
D (227994) canopen: ReadSDO #23 0x1000.00: InitUpload failed, CANopen error code 0xffffffff
|
||
|
D (228194) canopen: ReadSDO #25 0x1000.00: InitUpload failed, CANopen error code 0xffffffff
|
||
|
D (228444) canopen: ReadSDO #27 0x1000.00: InitUpload failed, CANopen error code 0xffffffff
|
||
|
D (228844) canopen: ReadSDO #30 0x1000.00: InitUpload failed, CANopen error code 0xffffffff
|
||
|
D (238384) canopen: ReadSDO #87 0x1000.00: InitUpload failed, CANopen error code 0xffffffff
|
||
|
|
||
|
This means one CANopen node was found, and some non-CANopen frames were
|
||
|
received on IDs 0x580 +23, +25, +27, +30 and +87.
|
||
|
|
||
|
|
||
|
Great! What now?
|
||
|
----------------
|
||
|
|
||
|
As you now know there's a CANopen node, you can look for documentation on it.
|
||
|
You can also try to access more default SDOs to see if you can control and
|
||
|
configure the node.
|
||
|
|
||
|
* If you're lucky, the device will provide its own EDS file at SDO 1021.00. You
|
||
|
can check that by issuing…::
|
||
|
|
||
|
OVMS# copen <bus> readsdo <nodeid> 1021 0
|
||
|
|
||
|
* Check out the `CiA specifications <https://www.can-cia.org/standardization/specifications/>`_,
|
||
|
for CANopen standards, for example…
|
||
|
|
||
|
- DS301 for details on general standard SDOs
|
||
|
- DS401 for the generic I/O device class definition
|
||
|
- DS402 for motor controller SDOs
|
||
|
|
||
|
* Look up the manufacturer of your device by it's vendor ID:
|
||
|
|
||
|
https://www.can-cia.org/services/canopen-vendor-id/
|
||
|
|
||
|
* Contact the manufacturer of your device for specific documentation and EDS files.
|
||
|
|