Metric name Example value Description
|
||
|
======================================== ======================== ============================================
|
||
|
xse.mybms.HW.rev 12,38,0 BMS hardware-revision year, week, patchlevel
|
||
|
xse.mybms.SW.rev 12,35,1 BMS soft-revision year, week, patchlevel
|
||
|
xse.mybms.adc.cvolts.max 4171 maximum cell voltages in mV, add offset +1500
|
||
|
xse.mybms.adc.cvolts.mean 4165 average cell voltage in mV, no offset
|
||
|
xse.mybms.adc.cvolts.min 4145 minimum cell voltages in mV, add offset +1500
|
||
|
xse.mybms.adc.volts.offset 103 calculated offset between RAW cell voltages and ADCref, about 90mV
|
||
|
xse.mybms.amps 65483A battery current in ampere (x/32) reported by by BMS
|
||
|
xse.mybms.amps2 2046.34A battery current in ampere read by live data on CAN or from BMS
|
||
|
xse.mybms.batt.vin WME4513901K661441 VIN stored in BMS
|
||
|
xse.mybms.dc.fault 0 Flag to show DC-isolation fault
|
||
|
xse.mybms.hv total voltage of HV system in V
|
||
|
xse.mybms.hv.contact.cycles.left 281991 counter related to ON/OFF cyles of the car
|
||
|
xse.mybms.hv.contact.cycles.max 300000 static, seems to be maxiumum of contactor cycles
|
||
|
xse.mybms.isolation 10239 Isolation in DC path, resistance in kOhm
|
||
|
xse.mybms.power 794.186kW power as product of voltage and amps in kW
|
||
|
xse.v.b.c.capacity 18491,18536,18536,... Cell capacity [As]
|
||
|
xse.v.b.c.capacity.dev.max 45.1,90.1,90.1,... Cell maximum capacity deviation observed [As]
|
||
|
xse.v.b.c.capacity.max 18491,18536,18536,... Cell maximum capacity [As]
|
||
|
xse.v.b.c.capacity.min 18491,18536,18536,... Cell minimum capacity [As]
|
||
|
xse.v.b.energy.used.reset 16.34kWh Energy used Reset (Dashbord)
|
||
|
xse.v.b.energy.used.start 16.9kWh Energy used Start (Dashbord)
|
||
|
xse.v.b.hv.active no HV Batterie Status
|
||
|
xse.v.b.p.capacity.as.average 18625 cell capacity statistics from BMS measurement cycle
|
||
|
xse.v.b.p.capacity.as.maximum 19193 cell capacity statistics from BMS measurement cycle
|
||
|
xse.v.b.p.capacity.as.minimum 18843 cell capacity statistics from BMS measurement cycle
|
||
|
xse.v.b.p.capacity.avg 18445.9 Cell capacity - pack average [As]
|
||
|
xse.v.b.p.capacity.combined.quality 0.515328 some sort of estimation factor??? constantly updated
|
||
|
xse.v.b.p.capacity.max 18670 Cell capacity - strongest cell in pack [As]
|
||
|
xse.v.b.p.capacity.max.cell 9 Cell capacity - number of strongest cell in pack
|
||
|
xse.v.b.p.capacity.min 18229 Cell capacity - weakest cell in pack [As]
|
||
|
xse.v.b.p.capacity.min.cell 59 Cell capacity - number of weakest cell in pack
|
||
|
xse.v.b.p.capacity.quality 0.742092 some sort of estimation factor??? after measurement cycle
|
||
|
xse.v.b.p.capacity.stddev 90.8 Cell capacity - current standard deviation [As]
|
||
|
xse.v.b.p.capacity.stddev.max 90.8 Cell capacity - maximum standard deviation observed [As]
|
||
|
xse.v.b.p.hv.lowcurrent 0Sec counter time of no current, reset e.g. with PLC heater or driving
|
||
|
xse.v.b.p.hv.off.time 0Sec HighVoltage contactor off time in seconds
|
||
|
xse.v.b.p.last.meas.days 13 days elapsed since last successful measurement
|
||
|
xse.v.b.p.ocv.timer 2676Sec counter time in seconds to reach OCV state
|
||
|
xse.v.b.p.voltage.max.cell 1 Cell volatage - number of strongest cell in pack
|
||
|
xse.v.b.p.voltage.min.cell 5 Cell volatage - number of weakest cell in pack
|
||
|
xse.v.b.real.soc 97.8% real state of charge
|
||
|
xse.v.bus.awake no CAN-Bus Status
|
||
|
xse.v.c.active no Charging Status
|
||
|
xse.v.display.time 738Min Dashbord Time
|
||
|
xse.v.display.trip.reset 2733.2km Dashbord Trip value at Reset
|
||
|
xse.v.display.trip.start 17.5km Dashbord Trip value at Start
|
||
|
xse.v.nlg6.amps.cablecode 0A Onboard Charger Ampere Cable
|
||
|
xse.v.nlg6.amps.chargingpoint 0A Onboard Charger Ampere ...
|
||
|
xse.v.nlg6.amps.setpoint 41A Onboard Charger Ampere setpoint
|
||
|
xse.v.nlg6.dc.current 0A Onboard Charger LV current Ampere
|
||
|
xse.v.nlg6.dc.hv 0V Onboard Charger HV Voltage
|
||
|
xse.v.nlg6.dc.lv 13.5V Onboard Charger LV Voltage
|
||
|
xse.v.nlg6.main.amps 0,0,0A Onboard Charger main Phasen Ampere
|
||
|
xse.v.nlg6.main.volts 0,0,0V Onboard Charger main Phasen Voltage
|
||
|
xse.v.nlg6.pn.hw 4519820621 Onboard Charger Hardware Serial No.
|
||
|
xse.v.nlg6.present no Onboard Charger OBL or NLG6 present
|
||
|
xse.v.nlg6.temp.coolingplate 0°C Onboard Charger coolingplate Temperature
|
||
|
xse.v.nlg6.temp.reported 0°C Onboard Charger reported Temperature
|
||
|
xse.v.nlg6.temp.socket 0°C Onboard Charger socket Temperature
|
||
|
xse.v.nlg6.temps Onboard Charger Temperatures
|
||
|
xse.v.pos.odometer.start 41940km Odo at last Ignition on. For Trip calc Value
|
||
|
xse.v.display.accel 89% Eco score on acceleration over last 6 hours
|
||
|
xse.v.display.const 18% Eco score on constant driving over last 6 hours
|
||
|
xse.v.display.coast 100% Eco score on coasting over last 6 hours
|
||
|
xse.v.display.ecoscore 69% Eco score shown on dashboard over last 6 hours
|
||
|
======================================== ======================== ============================================
|