2022-04-08 23:03:19 +00:00
|
|
|
/*
|
|
|
|
; Project: Open Vehicle Monitor System
|
2022-04-15 14:17:12 +00:00
|
|
|
; Date: 15th Apr 2022
|
2022-04-08 23:03:19 +00:00
|
|
|
;
|
2022-04-15 14:17:12 +00:00
|
|
|
; (C) 2022 Carsten Schmiemann
|
2022-04-08 23:03:19 +00:00
|
|
|
;
|
|
|
|
; Permission is hereby granted, free of charge, to any person obtaining a copy
|
|
|
|
; of this software and associated documentation files (the "Software"), to deal
|
|
|
|
; in the Software without restriction, including without limitation the rights
|
|
|
|
; to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
|
|
|
|
; copies of the Software, and to permit persons to whom the Software is
|
|
|
|
; furnished to do so, subject to the following conditions:
|
|
|
|
;
|
|
|
|
; The above copyright notice and this permission notice shall be included in
|
|
|
|
; all copies or substantial portions of the Software.
|
|
|
|
;
|
|
|
|
; THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
|
|
|
|
; IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
|
|
|
|
; FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
|
|
|
|
; AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
|
|
|
|
; LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
|
|
|
|
; OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN
|
|
|
|
; THE SOFTWARE.
|
|
|
|
*/
|
2022-04-10 18:30:54 +00:00
|
|
|
#include "vehicle_renaultzoe_ph2.h"
|
2022-04-08 23:03:19 +00:00
|
|
|
|
2022-04-15 14:17:12 +00:00
|
|
|
void OvmsVehicleRenaultZoePh2::IncomingHVAC(uint16_t type, uint16_t pid, const char* data, uint16_t len) {
|
|
|
|
switch (pid) {
|
|
|
|
case 0x4361: { //Cabin temperature
|
2022-04-17 21:17:42 +00:00
|
|
|
StandardMetrics.ms_v_env_cabintemp->SetValue(float((CAN_NIBL(0) - 40) * 0.1), Celcius);
|
|
|
|
ESP_LOGD(TAG, "4361 HVAC ms_v_env_cabintemp: %f", (CAN_NIBL(0) - 40) * 0.1);
|
2022-04-15 14:17:12 +00:00
|
|
|
break;
|
|
|
|
}
|
|
|
|
case 0x4360: { //Cabin setpoint
|
2022-04-17 12:25:03 +00:00
|
|
|
StandardMetrics.ms_v_env_cabinsetpoint->SetValue(float(((CAN_NIBL(0) + 32) / 2)), Celcius);
|
|
|
|
ESP_LOGD(TAG, "4360 HVAC ms_v_env_cabinsetpoint: %d", (CAN_NIBL(0) + 32) / 2);
|
2022-04-15 14:17:12 +00:00
|
|
|
break;
|
|
|
|
}
|
|
|
|
case 0x436B: { //Cabin FAN speed
|
2022-04-17 12:25:03 +00:00
|
|
|
StandardMetrics.ms_v_env_cabinfan->SetValue(float(CAN_UINT(0) * 0.5 * 0.1), Percentage);
|
|
|
|
ESP_LOGD(TAG, "436B HVAC ms_v_env_cabinfan: %f", CAN_UINT(0) * 0.5 * 0.1);
|
2022-04-15 14:17:12 +00:00
|
|
|
break;
|
|
|
|
}
|
|
|
|
case 0x43D8: { //Compressor speed
|
|
|
|
mt_hvac_compressor_speed->SetValue(float(CAN_UINT(0)));
|
|
|
|
ESP_LOGD(TAG, "43D8 HVAC mt_hvac_compressor_speed: %d", CAN_UINT(0));
|
|
|
|
break;
|
|
|
|
}
|
2022-04-18 00:16:56 +00:00
|
|
|
case 0x4402: { //Compressor state
|
|
|
|
if (CAN_NIBL(0) == 1) {
|
|
|
|
mt_hvac_compressor_mode->SetValue("AC mode");
|
|
|
|
StandardMetrics.ms_v_env_hvac->SetValue(true);
|
|
|
|
}
|
|
|
|
if (CAN_NIBL(0) == 2) {
|
|
|
|
mt_hvac_compressor_mode->SetValue("De-ICE mode");
|
|
|
|
StandardMetrics.ms_v_env_hvac->SetValue(true);
|
|
|
|
}
|
|
|
|
if (CAN_NIBL(0) == 4) {
|
|
|
|
mt_hvac_compressor_mode->SetValue("Heat pump mode");
|
|
|
|
StandardMetrics.ms_v_env_hvac->SetValue(true);
|
|
|
|
}
|
|
|
|
if (CAN_NIBL(0) == 6) {
|
|
|
|
mt_hvac_compressor_mode->SetValue("Demisting mode");
|
|
|
|
StandardMetrics.ms_v_env_hvac->SetValue(true);
|
|
|
|
}
|
|
|
|
if (CAN_NIBL(0) == 7) {
|
|
|
|
mt_hvac_compressor_mode->SetValue("idle");
|
|
|
|
StandardMetrics.ms_v_env_hvac->SetValue(false);
|
|
|
|
}
|
|
|
|
ESP_LOGD(TAG, "%d HVAC mt_hvac_compressor_mode: %d", pid, CAN_UINT(0));
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
case 0x4369: { //Compressor pressure
|
|
|
|
mt_hvac_compressor_pressure->SetValue(float(CAN_UINT(0) * 0.1));
|
|
|
|
ESP_LOGD(TAG, "%d HVAC mt_hvac_compressor_pressure: %f", pid, CAN_UINT(0) * 0.1);
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
case 0x4436: { //Compressor power
|
|
|
|
mt_hvac_compressor_power->SetValue(float(CAN_UINT(0) * 25.0 / 100.0));
|
|
|
|
ESP_LOGD(TAG, "%d HVAC mt_hvac_compressor_power: %f", pid, CAN_UINT(0) * 25.0 / 100.0);
|
|
|
|
break;
|
|
|
|
}
|
2022-04-16 02:51:35 +00:00
|
|
|
|
|
|
|
default: {
|
|
|
|
char *buf = NULL;
|
|
|
|
size_t rlen = len, offset = 0;
|
|
|
|
do {
|
|
|
|
rlen = FormatHexDump(&buf, data + offset, rlen, 16);
|
|
|
|
offset += 16;
|
|
|
|
ESP_LOGW(TAG, "OBD2: unhandled reply from HVAC [%02x %02x]: %s", type, pid, buf ? buf : "-");
|
|
|
|
} while (rlen);
|
|
|
|
if (buf)
|
|
|
|
free(buf);
|
|
|
|
break;
|
|
|
|
}
|
2022-04-15 14:17:12 +00:00
|
|
|
}
|
|
|
|
}
|