98 lines
2.8 KiB
Text
98 lines
2.8 KiB
Text
|
00,Device and failure type ODB codding
|
||
|
01,General Electrical Failure
|
||
|
02,General signal failure
|
||
|
03,FM (Frequency Modulated) - PWM (Pulse Width Modulated) Failures
|
||
|
04,System Internal Failures
|
||
|
05,System Programming Failures
|
||
|
06,Algorithm Based Failures
|
||
|
07,Mechanical Failures
|
||
|
08,Bus Signal / Message Failures
|
||
|
09,Component Failures
|
||
|
11,circuit short to ground
|
||
|
12,circuit short to battery
|
||
|
13,circuit open
|
||
|
14,circuit short to ground or open
|
||
|
15,circuit short to battery or open
|
||
|
16,circuit voltage below threshold
|
||
|
17,circuit voltage above threshold
|
||
|
18,circuit current below threshold
|
||
|
19,circuit current above threshold
|
||
|
1A,circuit resistance below threshold
|
||
|
1B,circuit resistance above threshold
|
||
|
1C,circuit voltage out of range
|
||
|
1D,circuit current out of range
|
||
|
1E,circuit resistance out of range
|
||
|
1F,circuit intermittent
|
||
|
21,signal amplitude < minimum
|
||
|
22,signal amplitude > maximum
|
||
|
23,signal stuck low
|
||
|
24,signal stuck high
|
||
|
25,signal shape / waveform failure
|
||
|
26,signal rate of change below threshold
|
||
|
27,signal rate of change above threshold
|
||
|
28,signal bias level out of range / zero adjustment failure
|
||
|
29,signal signal invalid
|
||
|
2F,signal erratic
|
||
|
31,no signal
|
||
|
32,signal low time < minimum
|
||
|
33,signal low time > maximum
|
||
|
34,signal high time < minimum
|
||
|
35,signal high time > maximum
|
||
|
36,signal frequency too low
|
||
|
37,signal frequency too high
|
||
|
38,signal frequency incorrect
|
||
|
39,incorrect has too few pulses
|
||
|
3A,incorrect has too many pulses
|
||
|
41,general checksum failure
|
||
|
42,general memory failure
|
||
|
43,special memory failure
|
||
|
44,data memory failure
|
||
|
45,program memory failure
|
||
|
46,calibration / parameter memory failure
|
||
|
47,watchdog / safety µC failure
|
||
|
48,supervision software failure
|
||
|
49,internal electronic failure
|
||
|
4A,incorrect component installed
|
||
|
4B,over temperature
|
||
|
51,not programmed
|
||
|
52,not activated
|
||
|
53,deactivated
|
||
|
54,missing calibration
|
||
|
55,not configured
|
||
|
61,signal calculation failure
|
||
|
62,signal compare failure
|
||
|
63,circuit / component protection time-out
|
||
|
64,signal plausibility failure
|
||
|
65,signal has too few transitions / events
|
||
|
66,signal has too many transitions / events
|
||
|
67,signal incorrect after event
|
||
|
68,event information
|
||
|
71,actuator stuck
|
||
|
72,actuator stuck open
|
||
|
73,actuator stuck closed
|
||
|
74,actuator slipping
|
||
|
75,emergency position not reachable
|
||
|
76,wrong mounting position
|
||
|
77,commanded position not reachable
|
||
|
78,alignment or adjustment incorrect
|
||
|
79,mechanical linkage failure
|
||
|
7A,fluid leak or seal failure
|
||
|
7B,low fluid level
|
||
|
81,invalid serial data received
|
||
|
82,alive / sequence counter incorrect / not updated
|
||
|
83,value of signal protection calculation incorrect
|
||
|
84,signal below allowable range
|
||
|
85,signal above allowable range
|
||
|
86,signal invalid
|
||
|
87,missing message
|
||
|
88,bus off
|
||
|
8F,erratic
|
||
|
91,parametric
|
||
|
92,performance or incorrect operation
|
||
|
93,no operation
|
||
|
94,unexpected operation
|
||
|
95,incorrect assembly
|
||
|
96,component internal failure
|
||
|
97,Component or system operation obstructed or blocked
|
||
|
98,component or system over temperature
|