test cases: - ID: BTSTK_MISC_0101 SDK: ESP32_IDF Test App: SSC_BLE auto test: 'Yes' category: Function test point 1: basic function test point 2: bt init and enable summary: correct init and deinit flow steps: '1. disable and deinit bt 2. init bt 3. deinit bt 4. init and enable bt 5. disable and deinit bt' expected result: '1. succeed 2. succeed 3. succeed 4. succeed 5. succeed' initial condition: BLE_DEINIT1 test environment: SSC_T1_1 execution time: 0 module: BT Stack sub module: Misc version: v1 (2016-12-31) CI ready: 'Yes' level: Integration allow fail: '' cmd set: - "" - - "SSC SSC1 bt -D -z stop" - ["R SSC1 C +BT"] - - "SSC SSC1 bt -D -z init" - ["R SSC1 C +BT:OK"] - - "SSC SSC1 bt -D -z deinit" - ["R SSC1 C +BT:OK"] - - "SSC SSC1 bt -D -z start" - ["R SSC1 C +BT:OK"] - - "SSC SSC1 bt -D -z stop" - ["R SSC1 C +BT:OK"] - ID: BTSTK_MISC_0102 SDK: ESP32_IDF Test App: SSC_BLE auto test: 'Yes' category: Function test point 1: basic function test point 2: bt init and enable summary: incorrect deinit disable flow steps: '1. disable and deinit bt 2. init and enable bt 3. deinit bt 4. disable bt 5. disable bt 6. deinit bt 7. deinit bt 8. disable bt' expected result: '1. succeed 2. succeed 3. fail 4. succeed 5. fail 6. succeed 7. fail 8. fail' initial condition: BLE_DEINIT1 test environment: SSC_T1_1 execution time: 0 module: BT Stack sub module: Misc version: v1 (2016-12-31) CI ready: 'Yes' level: Integration allow fail: '' cmd set: - "" - - "SSC SSC1 bt -D -z stop" - ["R SSC1 C +BT"] - - "SSC SSC1 bt -D -z start" - ["R SSC1 C +BT:OK"] - - "SSC SSC1 bt -D -z deinit" - ["R SSC1 C +BT:ERROR"] - - "SSC SSC1 bt -D -z disable" - ["R SSC1 C +BT:OK"] - - "SSC SSC1 bt -D -z disable" - ["R SSC1 C +BT:ERROR"] - - "SSC SSC1 bt -D -z deinit" - ["R SSC1 C +BT:OK"] - - "SSC SSC1 bt -D -z deinit" - ["R SSC1 C +BT:ERROR"] - - "SSC SSC1 bt -D -z disable" - ["R SSC1 C +BT:ERROR"] - ID: BTSTK_MISC_0103 SDK: ESP32_IDF Test App: SSC_BLE auto test: 'Yes' category: Function test point 1: basic function test point 2: bt init and enable summary: incorrect init enable flow steps: '1. disable and deinit bt 2. enable bt 3. init bt 4. init bt 5. enable bt 6. enable bt 7. init bt' expected result: '1. succeed 2. fail 3. succeed 4. fail 5. succeed 6. fail 7. fail' initial condition: BLE_DEINIT1 test environment: SSC_T1_1 execution time: 0 module: BT Stack sub module: Misc version: v1 (2016-12-31) CI ready: 'Yes' level: Integration allow fail: '' cmd set: - "" - - "SSC SSC1 bt -D -z stop" - ["R SSC1 C +BT"] - - "SSC SSC1 bt -D -z enable" - ["R SSC1 C +BT:ERROR"] - - "SSC SSC1 bt -D -z init" - ["R SSC1 C +BT:OK"] - - "SSC SSC1 bt -D -z init" - ["R SSC1 C +BT:ERROR"] - - "SSC SSC1 bt -D -z enable" - ["R SSC1 C +BT:OK"] - - "SSC SSC1 bt -D -z enable" - ["R SSC1 C +BT:ERROR"] - - "SSC SSC1 bt -D -z init" - ["R SSC1 C +BT:ERROR"]