menu "Example Configuration" menu "I2C Master" config I2C_MASTER_SCL int "SCL GPIO Num" default 19 help GPIO number for I2C Master clock line. config I2C_MASTER_SDA int "SDA GPIO Num" default 18 help GPIO number for I2C Master data line. config I2C_MASTER_PORT_NUM int "Port Number" default 1 help Port number for I2C Master device. config I2C_MASTER_FREQUENCY int "Master Frequency" default 100000 help I2C Speed of Master device. endmenu menu "I2C Slave" config I2C_SLAVE_SCL int "SCL GPIO Num" default 26 help GPIO number for I2C Slave clock line. config I2C_SLAVE_SDA int "SDA GPIO Num" default 25 help GPIO number for I2C Slave data line. config I2C_SLAVE_PORT_NUM int "Port Number" default 0 help Port number for I2C Slave device. config I2C_SLAVE_ADDRESS hex "ESP Slave Address" default 0x28 help Hardware Address of I2C Slave Port. endmenu menu "BH1750 Sensor" choice BH1750_ADDR prompt "BH1750 I2C Address" default BH1750_I2C_ADDRESS_LOW help Hardware address of BH1750, which is 2 types, and determined by ADDR terminal. config BH1750_I2C_ADDRESS_LOW bool "BH1750 I2C Address(ADDR=0)" help I2C Address of BH1750 Sensor according to your schemetic configuration. config BH1750_I2C_ADDRESS_High bool "BH1750 I2C Address(ADDR=1)" help I2C Address of BH1750 Sensor according to your schemetic configuration. endchoice config BH1750_ADDR hex default 0x5C if BH1750_I2C_ADDRESS_High default 0x23 if BH1750_I2C_ADDRESS_LOW choice BH1750_MODE prompt "BH1750 Operation Mode" default BH1750_ONETIME_L_RESOLUTION help Operation Mode of BH1750. Different mode means different resolution and measurement time. config BH1750_CONTINU_H_RESOLUTION bool "Continuously H-Resolution Mode" help Resolution is 1lx, measurement time is typically 120ms. config BH1750_CONTINU_H_RESOLUTION2 bool "Continuously H-Resolution Mode2" help Resolution is 0.5lx, measurement time is typically 120ms. config BH1750_CONTINU_L_RESOLUTION bool "Continuously L-Resolution Mode" help Resolution is 4lx, measurement time is typically 16ms. config BH1750_ONETIME_H_RESOLUTION bool "One Time H-Resolution Mode" help Resolution is 1lx, measurement time is typically 120ms. It is automatically set to Power Down mode after measurement. config BH1750_ONETIME_H_RESOLUTION2 bool "One Time H-Resolution Mode2" help Resolution is 0.5lx, measurement time is typically 120ms. It is automatically set to Power Down mode after measurement. config BH1750_ONETIME_L_RESOLUTION bool "One Time L-Resolution Mode" help Resolution is 4lx, measurement time is typically 16ms. It is automatically set to Power Down mode after measurement. endchoice config BH1750_OPMODE hex default 0x10 if BH1750_CONTINU_H_RESOLUTION default 0x11 if BH1750_CONTINU_H_RESOLUTION2 default 0x13 if BH1750_CONTINU_L_RESOLUTION default 0x20 if BH1750_ONETIME_H_RESOLUTION default 0x21 if BH1750_ONETIME_H_RESOLUTION2 default 0x23 if BH1750_ONETIME_L_RESOLUTION endmenu endmenu