Commit graph

44 commits

Author SHA1 Message Date
lly bc1722260f ble_mesh: Group resends in proxy nodes [Zephyr]
Resend transport segments for groups on the advertiser interface, even
if a connected proxy node holds the group.
2020-05-13 03:40:30 +00:00
lly 968772d18a ble_mesh: Typo in condition in comp_add_elem of cfg_srv [Zephyr]
Vendor model IDs take up four (not two) bytes in the composition
2020-05-13 03:40:30 +00:00
lly a45406fe6e ble_mesh: GATT Proxy Spec 1.0.1 changes [Zephyr]
Backport of https://github.com/apache/mynewt-nimble/pull/724

Mesh spec 1.0.1 changes proxy disabling behavior to only affect the
relaying from proxy nodes. Previously, disabling proxy would shut down
all proxy and node activity.

Tweaks from the original commit:
- Removed redundant call to bt_mesh_adv_update() in gatt_proxy_set()
- Removed invalid ref to 4.2.11.1 in node_identity_set()

---

According to Mesh Profile Spec 1.0.1, Section 4.2.11:
"If the Proxy feature is disabled, a GATT client device can connect
over GATT to that node for configuration and control. Messages from
the GATT bearer are not relayed to the advertising bearer."

Moreover some notes have been removed from the spec compared to
version 1.0:

Mesh Profile Spec 1.0, Section 4.2.11:

"Upon transition from GATT Proxy state 0x01 to GATT Proxy state 0x00
the GATT Bearer Server shall disconnect all GATT Bearer Clients."

"The Configuration Client should turn off the Proxy state as the last
step in the configuration process."

Mesh Profile Spec 1.0, Section 4.2.11.1:

"When the GATT Proxy state is set to 0x00, the Node Identity state
for all subnets shall be set to 0x00 and shall not be changed."
2020-05-13 03:40:30 +00:00
lly 10f2ed14eb ble_mesh: Support reliable sending when publishing [Zephyr]
Until now the choice of reliable sending (segmented messages with
acks) was implicitly dependent on the size of the payload. Add a new
member to the bt_mesh_model_pub to force using segment acks even when
the payload would fit a single unsegmented message.
2020-05-13 03:40:30 +00:00
lly cd19f6faf1 ble_mesh: Check device uuid when init provisioning 2020-05-13 03:40:30 +00:00
lly abcfcc47ec ble_mesh: Fix provisioning buffer initialization [Zephyr]
When PB-GATT support has been enabled the provisioning code "borrows"
the buffer from the proxy code. However, the way that initialization
was happening the proxy buffers were initialized only after
provisioning initialization, resulting in a corrupted buffer with
buf->data pointing to NULL. Reorder the initialization calls so that
proxy is done first and provisioning only after it.
2020-05-13 03:40:30 +00:00
lly e580f98b44 ble_mesh: Skip publish if update fails [Zephyr]
Allow models to skip a periodic publish interval by returning an error
from the publish update callback.

Previously, an error return from publish update would cancel periodic
publishing. This can't be recovered from, and as such, no valid model
implementation could return an error from this callback, and there was
no way to skip a periodic publish.
2020-05-13 03:40:30 +00:00
lly 50b4bea45c ble_mesh: Enable Segmented Control Messages [Zephyr]
The function bt_mesh_ctl_send() used to support maximum length of
11 bytes. The segmentation complies with the BLE Mesh Standard.
The ack is disabled in case of non unicast address.
2020-05-13 03:40:30 +00:00
Island 2c1c87b37d Merge branch 'bugfix/ble_mesh_add_missing_cpp_v3.3' into 'release/v3.3'
ble_mesh: Add missing #ifdef __cplusplus (v3.3)

See merge request espressif/esp-idf!8615
2020-05-06 18:16:20 +08:00
Island 4ac84bca8b Merge branch 'bugfix/ble_mesh_compile_error_o2_v3.3' into 'release/v3.3'
ble_mesh: Fix compile error when -O2 (performance) is chosen (v3.3)

See merge request espressif/esp-idf!8618
2020-05-06 18:15:28 +08:00
Island 5a53e67c7e Merge branch 'bugfix/ble_mesh_provisioner_check_key_v3.3' into 'release/v3.3'
ble_mesh: Check if appkey exist before deleting it (v3.3)

See merge request espressif/esp-idf!8619
2020-05-06 18:09:32 +08:00
lly 745aecb03d ble_mesh: Fix node not erase info completely
Previously only mesh node info is supported to be stored
in flash. So when trying to reset the node, we only need
to judge if the BLE_MESH_VALID flag is set.
Currently we support storing both node & Provisioner info
in flash, when trying to erase the node info from flash,
the BLE_MESH_NODE flag will be checked. So we need to set
bt_mesh.flags to 0 when all the erase operations are done.
2020-05-06 11:45:02 +08:00
lly e36d1d2f8a ble_mesh: Check if appkey exist before deleting it 2020-05-06 11:37:03 +08:00
lly 1432daf4c6 ble_mesh: Add length check for some mesh operations 2020-05-06 11:33:41 +08:00
lly 6e7d43dd89 ble_mesh: Fix compile error when -O2 (performance) is chosen 2020-05-06 11:33:08 +08:00
lly 3b9e0657d8 ble_mesh: Add missing #ifdef __cplusplus 2020-05-06 11:19:05 +08:00
Island 53a0b3f951 Merge branch 'feat/ble_mesh_ble_adv_simultaneously_v3.3' into 'release/v3.3'
ble_mesh: Support BLE advertising simultaneously (v3.3)

See merge request espressif/esp-idf!8486
2020-05-06 11:14:52 +08:00
lly eedaf45f43 ble_mesh: Continue node info restore even if failure happens
During BLE Mesh Provisioner initialization, the stack will restore
the nodes information if settings storage is enabled.
Previously when a failure happens (e.g. found the same uuid) during
the restore procedure, the information of the following nodes will
not be restored and error will be directly returned.
But this will introduce some problem with user experience, because
some newly provisioned nodes information will not be restored and
Provisioner will not be able to control those nodes.
So we change the operation here, when a failure happens during the
restore procedure, Provisioner will only ignore the information of
the current node and continue restoring other nodes information.
2020-04-30 11:47:12 +00:00
lly eabf436a23 ble_mesh: Remove some redundant functions 2020-04-30 11:47:12 +00:00
lly 63ab37d721 ble_mesh: Notify unprovisioned device beacon to application layer
With this change, if a Provisioner has provisioned the maximum
number of nodes, it can still report the unprovisioned device
beacon from other nodes to the application layer. And this will
be more reasonable compared with the previous implementation.
Previously when the node array of Provisioner is full, no beacon
from unprovisioned devices will be reported, only some warning
logs will be given.
2020-04-30 11:47:12 +00:00
lly 77cf16e337 ble_mesh: Check if assigned node address is duplicated
Previously only check the node address when it is assigned by the
application layer. Here we also check the address when the address
is allocated internally. And this will be useful when some mesh
internal tests are performed.
2020-04-30 11:47:12 +00:00
lly 80feb4e70a ble_mesh: Update next alloc address when node info is added 2020-04-30 11:47:12 +00:00
lly 9cb7faf4bd ble_mesh: Fix Provisioner provisioning deadlock 2020-04-30 11:47:12 +00:00
lly fecfd754d9 ble_mesh: Remove BLE_MESH_MAX_STORED_NODES option
Previously the BLE_MESH_MAX_STORED_NODES option is added for
internal mesh test, which will be a little confusing for the
users to understand.
Here we remove this option, instead the BLE_MESH_MAX_PROV_NODES
will be used for all the cases. For mesh internal test, when
the test function is called to add some nodes info, the info
will be stored in the array of provisioned nodes directly.
2020-04-30 11:47:12 +00:00
lly 9b1b2f9b5d ble_mesh: Support BLE advertising simultaneously 2020-04-30 08:23:24 +00:00
lly 012b810d29 ble_mesh: Add ble mesh white list test function
Using the ble mesh white list test functions, a node can choose to
only receive mesh messages from a specific node and relay the
messages for it. Messages from other nodes will be ignored.
2020-04-26 06:44:45 +00:00
lly cc07e9d203 ble_mesh: Fix ble mesh nimble host deinit 2020-03-17 14:42:46 +08:00
Jiang Jiang Jian bf568f2eb4 Merge branch 'bugfix/ble_mesh_miscellaneous_fix_v3.3' into 'release/v3.3'
Bugfix/ble mesh miscellaneous fix (v3.3)

See merge request espressif/esp-idf!7971
2020-03-16 13:27:35 +08:00
lly a8763e6517 ble_mesh: Move dev_role to the end of model_pub 2020-03-13 19:53:26 +08:00
lly de022501b7 ble_mesh: Use the right netkey during iv update 2020-03-13 19:53:23 +08:00
lly 0d6dd36af9 ble_mesh: Use the right net_idx & app_idx for publish 2020-03-13 19:53:19 +08:00
lly 68dba56ac8 ble_mesh: Check buf->ref before unref the buffer 2020-03-13 19:53:16 +08:00
lly 9f32f4b405 ble_mesh: Fix mesh memory use-after-free issue 2020-03-13 19:53:12 +08:00
lly c19a01d100 ble_mesh: Add ble mesh deinit in btc task 2020-03-13 19:53:08 +08:00
lly 2ae6eedb30 ble_mesh: Free beacon timer when deinit mesh 2020-03-13 19:53:02 +08:00
lly 0e2c77b185 ble_mesh: Calc incomplete timeout based on msg info 2020-02-27 15:47:26 +08:00
lly 49fc8c86b3 ble_mesh: Unify client application and lower transport layer timeout 2020-02-27 15:46:19 +08:00
lly 9fa5c14d58 ble_mesh: Reset transport info when node is removed 2020-02-27 15:45:46 +08:00
lly cc19e1da9b ble_mesh: Provisioner ignores msg from removed node 2020-02-27 15:45:15 +08:00
gengyuchao 53664c80ff component/bt: Fix the issue with pointer type conversion in gattc. Unified att(db_sizedb_size) count pointer type in bta and btc, change pointer type in bta from int to uint16_t. 2020-02-20 19:16:01 +08:00
Hrishikesh Dhayagude cf6f1e8246 Add support of NimBLE host in ESP-BLE-Mesh - v3.3 2020-02-13 12:33:23 +05:30
Hrishikesh Dhayagude a03b9c7465 Add NimBLE files in ESP-BLE-Mesh again
Revert "ble_mesh: Remove NimBLE implementation for ESP-BLE-MESH"

This reverts commit 925f93614c.
2020-02-05 13:37:54 +05:30
lly 925f93614c ble_mesh: Remove NimBLE implementation for ESP-BLE-MESH 2020-02-03 12:04:00 +08:00
lly b19671e0d4 ble_mesh: Add ESP BLE Mesh implementation
1. BLE Mesh Core

    * Provisioning: Node Role
        * PB-ADV and PB-GATT
        * Authentication OOB

    * Provisioning: Provisioner Role
        * PB-ADV and PB-GATT
        * Authentication OOB

    * Networking
        * Relay
        * Segmentation and Reassembly
        * Key Refresh
        * IV Update

    * Proxy Support

    * Multiple Client Models Run Simultaneously
        * Support multiple client models send packets to different nodes simultaneously
        * No blocking between client model and server

    * NVS Storage
        * Store BLE Mesh node related information in flash
        * Store BLE Mesh Provisioner related information in flash

2. BLE Mesh Models

    * Foundation Models
        * Configuration Server Model
        * Configuration Client Model
        * Health Server Model
        * Health Client Model

    * Generic
        * Generic OnOff Server
        * Generic OnOff Client
        * Generic Level Server
        * Generic Level Client
        * Generic Default Transition Time Server
        * Generic Default Transition Time Client
        * Generic Power OnOff Server
        * Generic Power OnOff Setup Server
        * Generic Power OnOff Client
        * Generic Power Level Server
        * Generic Power Level Setup Server
        * Generic Power Level Client
        * Generic Battery Server
        * Generic Battery Client
        * Generic Location Server
        * Generic Location Setup Server
        * Generic Location Client
        * Generic Admin Property Server
        * Generic Manufacturer Property Server
        * Generic User Property Server
        * Generic Client Property Server
        * Generic Property Client

    * Sensor Server Model
        * Sensor Server
        * Sensor Setup Server
        * Sensor Client

    * Time and Scenes
        * Time Server
        * Time Setup Server
        * Time Client
        * Scene Server
        * Scene Setup Server
        * Scene Client
        * Scheduler Server
        * Scheduler Setup Server
        * Scheduler Client

    * Lighting
        * Light Lightness Server
        * Light Lightness Setup Server
        * Light Lightness Client
        * Light CTL Server
        * Light CTL Setup Server
        * Light CTL Client
        * Light CTL Temperature Server
        * Light HSL Server
        * Light HSL Setup Server
        * Light HSL Client
        * Light HSL Hue Server
        * Light HSL Saturation Server
        * Light xyL Server
        * Light xyL Setup Server
        * Light xyL Client
        * Light LC Server
        * Light LC Setup Server
        * Light LC Client

3. BLE Mesh Applications

    * BLE Mesh Node
        * OnOff Client Example
        * OnOff Server Example

    * BLE Mesh Provisioner
        * Example

    * Fast Provisioning
        * Vendor Fast Prov Server Model
        * Vendor Fast Prov Client Model
        * Examples

    * Wi-Fi & BLE Mesh Coexistence
        * Example

    * BLE Mesh Console Commands
        * Examples
2020-02-03 12:03:36 +08:00