Bugfix/collection of confirmed fixes from baidu project
Closes BT-826, BT-542, BCI-31, BCI-34, BT-840, and AUD-1857
See merge request espressif/esp-idf!8675
The transport segmented TX nack and seg_pending fields must be at least
6 bits to avoid overflow for 32 segment messages. This change rearranges
the seg_tx fields to gather all state flag fields in one byte, while
making the counter fields whole bytes.
Ensures that friend messages are enqueued, even if the packet is
received with an appkey is unknown to the friend. Previously, sdu_recv
would return EINVAL if the appkey was unknown, which would prevent the
lower transport layer from adding the packet to the friend queue. This
is irrelevant for the logic in lower transport, and should not be
returned as an error.
Device name will be reset when deinit mesh stack. If not
initializing device name during the next mesh stack init,
it will fail to set the device name when using bluedroid.
Since bt_mesh_friend_init() will only be invoked when
a device is provisioned or Provisioner is enabled, so
we add a flag to indicate if the friend functionality
is initialized in case deinit before initialization.
Old version of BLE Mesh has no device role storage, because
previously we only support storing mesh node info.
If the binary of the node is upgraded from old version to a
new version (support storing provisioner info), the mesh info
of the node will not be restored because mesh role does not
exist in the flash.
When fast provisioning is enabled, Provisioner shall not
ignore messages from the nodes whose addresses are not in
the provisioning database. Because other nodes which are
not provisioned by the Primary Provisioner will send node
address messages to the Primary Provisioner.
When using fast provisioning, the Provisioner functionality
will be enabled. Unicast addresses within the pre-allocated
range will be used for provisioning nodes. And during the
address assignment, the allocated unicast address will be
checked that if it's duplicated with other nodes addresses
and the Provisioner's own addresses.
So before starting using fast provisioning, we need to update
the Provisioner address.
Since the behavior of sending segmented messages has been
changed properly, the calculation of timeout value which
will be used when sending an acknowledged message by a
client model also needs to be updated.
Add mutex to protect some variables of the mesh segmented
messages.
Currently the timeout handler of mesh will be executed in
the btc task, while the received mesh messages will be
handled in the btu task. In case some variables are set to
NULL when handled in the btu task, meanwhile these variables
are also accessed in the timeout handler, so we add mutex to
protect these variables and related operations.