Merge branch 'docs/add_note_for_ulp_set_wakeup_period' into 'master'

ulp: add note regarding limitation of ulp_set_wakeup_period in deep sleep mode

See merge request idf/esp-idf!3796
This commit is contained in:
Ivan Grokhotkov 2018-12-07 14:07:14 +08:00
commit 8b885fb935
3 changed files with 5 additions and 2 deletions

View file

@ -898,6 +898,9 @@ esp_err_t ulp_run(uint32_t entry_point);
* i.e. period number 0. ULP program code can use SLEEP instruction to select
* which of the SENS_ULP_CP_SLEEP_CYCx_REG should be used for subsequent wakeups.
*
* However, please note that SLEEP instruction issued (from ULP program) while the system
* is in deep sleep mode does not have effect, and sleep cycle count 0 is used.
*
* @param period_index wakeup period setting number (0 - 4)
* @param period_us wakeup period, us
* @note The ULP FSM requires two clock cycles to wakeup before being able to run the program.

View file

@ -152,7 +152,7 @@ ULP program flow
ULP coprocessor is started by a timer. The timer is started once ``ulp_run`` is called. The timer counts a number of RTC_SLOW_CLK ticks (by default, produced by an internal 150kHz RC oscillator). The number of ticks is set using ``SENS_ULP_CP_SLEEP_CYCx_REG`` registers (x = 0..4). When starting the ULP for the first time, ``SENS_ULP_CP_SLEEP_CYC0_REG`` will be used to set the number of timer ticks. Later the ULP program can select another ``SENS_ULP_CP_SLEEP_CYCx_REG`` register using ``sleep`` instruction.
The application can set ULP timer period values (SENS_ULP_CP_SLEEP_CYCx_REG, x = 0..4) using ``ulp_wakeup_period_set`` function.
The application can set ULP timer period values (SENS_ULP_CP_SLEEP_CYCx_REG, x = 0..4) using ``ulp_set_wakeup_period`` function.
.. doxygenfunction:: ulp_set_wakeup_period

View file

@ -151,7 +151,7 @@ ULP program flow
ULP coprocessor is started by a timer. The timer is started once ``ulp_run`` is called. The timer counts a number of RTC_SLOW_CLK ticks (by default, produced by an internal 150kHz RC oscillator). The number of ticks is set using ``SENS_ULP_CP_SLEEP_CYCx_REG`` registers (x = 0..4). When starting the ULP for the first time, ``SENS_ULP_CP_SLEEP_CYC0_REG`` will be used to set the number of timer ticks. Later the ULP program can select another ``SENS_ULP_CP_SLEEP_CYCx_REG`` register using ``sleep`` instruction.
The application can set ULP timer period values (SENS_ULP_CP_SLEEP_CYCx_REG, x = 0..4) using ``ulp_wakeup_period_set`` function.
The application can set ULP timer period values (SENS_ULP_CP_SLEEP_CYCx_REG, x = 0..4) using ``ulp_set_wakeup_period`` function.
.. doxygenfunction:: ulp_set_wakeup_period