ULP: remove deprecated cycle_sel field from ADC instruction
Cycle_sel field was never used in binutils and was always set to zero. This change removes it from documentation and examples. Needs ULP binutils with this change: https://github.com/espressif/binutils-esp32ulp/commit/af79434
This commit is contained in:
parent
d718cbd873
commit
7abd9bc023
2 changed files with 7 additions and 7 deletions
|
@ -651,21 +651,21 @@ Similar considerations apply to ``LD`` and ``ST`` instructions. Consider the fol
|
|||
---------------------------------
|
||||
|
||||
**Syntax**
|
||||
**ADC** *Rdst, Sar_sel, Mux, Cycles*
|
||||
- **ADC** *Rdst, Sar_sel, Mux*
|
||||
|
||||
- **ADC** *Rdst, Sar_sel, Mux, 0* — deprecated form
|
||||
|
||||
**Operands**
|
||||
- *Rdst* – Destination Register R[0..3], result will be stored to this register
|
||||
- *Sar_sel* – selected ADC : 0=SARADC0, 1=SARADC1
|
||||
- *Rdst* – Destination Register R[0..3], result will be stored to this register
|
||||
- *Sar_sel* – Select ADC: 0 = SARADC1, 1 = SARADC2
|
||||
- *Mux* - selected PAD, SARADC Pad[Mux+1] is enabled
|
||||
- *Cycle* – number of cycles used to perform measurement
|
||||
|
||||
**Description**
|
||||
The instruction makes measurements from ADC.
|
||||
|
||||
**Examples**::
|
||||
|
||||
1: ADC R1, 0, 1, 100 // Measure value using ADC1 pad 2,
|
||||
// for 100 cycles and move result to R1
|
||||
1: ADC R1, 0, 1 // Measure value using ADC1 pad 2 and store result into R1
|
||||
|
||||
|
||||
**REG_RD** – read from peripheral register
|
||||
|
|
|
@ -72,7 +72,7 @@ entry:
|
|||
stage_rst
|
||||
measure:
|
||||
/* measure and add value to accumulator */
|
||||
adc r1, 0, adc_channel + 1, 0
|
||||
adc r1, 0, adc_channel + 1
|
||||
add r0, r0, r1
|
||||
/* increment loop counter and check exit condition */
|
||||
stage_inc 1
|
||||
|
|
Loading…