Merge branch 'doc/adc1_channel_config' into 'master'
adc: Add doc details about configure not needed before each read See merge request idf/esp-idf!2132
This commit is contained in:
commit
1a157279e0
1 changed files with 21 additions and 7 deletions
|
@ -147,11 +147,15 @@ esp_err_t adc1_config_width(adc_bits_width_t width_bit);
|
||||||
esp_err_t adc_set_data_width(adc_unit_t adc_unit, adc_bits_width_t width_bit);
|
esp_err_t adc_set_data_width(adc_unit_t adc_unit, adc_bits_width_t width_bit);
|
||||||
|
|
||||||
/**
|
/**
|
||||||
* @brief Configure the ADC1 channel, including setting attenuation.
|
* @brief Set the attenuation of a particular channel on ADC1, and configure its
|
||||||
|
* associated GPIO pin mux.
|
||||||
*
|
*
|
||||||
* @note This function also configures the input GPIO pin mux to
|
* @note For any given channel, this function must be called before the first time
|
||||||
* connect it to the ADC1 channel. It must be called before calling
|
* adc1_get_raw() is called for that channel.
|
||||||
* adc1_get_raw() for this channel.
|
*
|
||||||
|
* @note This function can be called multiple times to configure multiple
|
||||||
|
* ADC channels simultaneously. adc1_get_raw() can then be called for any configured
|
||||||
|
* channel.
|
||||||
*
|
*
|
||||||
* The default ADC full-scale voltage is 1.1V. To read higher voltages (up to the pin maximum voltage,
|
* The default ADC full-scale voltage is 1.1V. To read higher voltages (up to the pin maximum voltage,
|
||||||
* usually 3.3V) requires setting >0dB signal attenuation for that ADC channel.
|
* usually 3.3V) requires setting >0dB signal attenuation for that ADC channel.
|
||||||
|
@ -168,6 +172,15 @@ esp_err_t adc_set_data_width(adc_unit_t adc_unit, adc_bits_width_t width_bit);
|
||||||
*
|
*
|
||||||
* @note At 11dB attenuation the maximum voltage is limited by VDD_A, not the full scale voltage.
|
* @note At 11dB attenuation the maximum voltage is limited by VDD_A, not the full scale voltage.
|
||||||
*
|
*
|
||||||
|
* Due to ADC characteristics, most accurate results are obtained within the following approximate voltage ranges:
|
||||||
|
*
|
||||||
|
* - 0dB attenuaton (ADC_ATTEN_DB_0) between 100 and 950mV
|
||||||
|
* - 2.5dB attenuation (ADC_ATTEN_DB_2_5) between 100 and 1250mV
|
||||||
|
* - 6dB attenuation (ADC_ATTEN_DB_6) between 150 to 1750mV
|
||||||
|
* - 11dB attenuation (ADC_ATTEN_DB_11) between 150 to 2450mV
|
||||||
|
*
|
||||||
|
* For maximum accuracy, use the ADC calibration APIs and measure voltages within these recommended ranges.
|
||||||
|
*
|
||||||
* @param channel ADC1 channel to configure
|
* @param channel ADC1 channel to configure
|
||||||
* @param atten Attenuation level
|
* @param atten Attenuation level
|
||||||
*
|
*
|
||||||
|
@ -178,13 +191,14 @@ esp_err_t adc_set_data_width(adc_unit_t adc_unit, adc_bits_width_t width_bit);
|
||||||
esp_err_t adc1_config_channel_atten(adc1_channel_t channel, adc_atten_t atten);
|
esp_err_t adc1_config_channel_atten(adc1_channel_t channel, adc_atten_t atten);
|
||||||
|
|
||||||
/**
|
/**
|
||||||
* @brief Take an ADC1 reading on a single channel
|
* @brief Take an ADC1 reading from a single channel.
|
||||||
*
|
*
|
||||||
* @note Call adc1_config_width() before the first time this
|
* @note Call adc1_config_width() before the first time this
|
||||||
* function is called.
|
* function is called.
|
||||||
*
|
*
|
||||||
* @note For a given channel, adc1_config_channel_atten(channel)
|
* @note For any given channel, adc1_config_channel_atten(channel)
|
||||||
* must be called before the first time this function is called.
|
* must be called before the first time this function is called. Configuring
|
||||||
|
* a new channel does not prevent a previously configured channel from being read.
|
||||||
*
|
*
|
||||||
* @param channel ADC1 channel to read
|
* @param channel ADC1 channel to read
|
||||||
*
|
*
|
||||||
|
|
Loading…