OVMS3-idf/components/freemodbus/common/include/esp_modbus_master.h

250 lines
11 KiB
C
Raw Normal View History

freemodbus: Fix bug with incorrect coils read mask Contains two different component folders per each implementation (serial_master and serial_slave) with concrete ports. Added common public api for master and slave and common interface for master and slave implementation. Add support of cmake system (added cmake files). Added sdkconfig.defaults files for slave and master modbus examples. Updated make file and KConfig for freemodbus component Update according to review and fix doxygen warnings Fix Doxyfile to pass documentation build Update headers and change interface file names as per review comments Merge branch feature/freemodbus_move_rs485_mode_control Update after review: The stack modbus folder updated to support master and slave ports together and moved into freemodbus/modbus Stack and port files updated to remove duplicated simbols Make file, KConfig and CMakeLists.txt updated to compile master and slave stacks, common interface and concrete implementations of ports Stack callback functions execute callbacks using interface pointer from concrete port implementation User can instantiate any of concrete port using common API (only one concrete port at a time) and it does not require to select port by KConfig Port pins and mode configuration moved into example files from port files to allow user select pins and port mode (customer request) Changes tested using pymodbus, ModbusPoll and communication between two boards Updated DoxyFile according to public include path Fix maximum instance size for slave (merge from master of customer issue) Fix critical section issue TW#28622 (change spin lock based critical section to semaphore) Move serial port files into component port folder for master and slave accordingly Fix example issue showed in the log when IO slave is not configured correctly Fix conflicts while merging from origin/master Fix errors handling in modbus controller interface + some final corrections according to review Update maximum allowed number of slaves in the network segment Fix bug with incorrect coils read mask Closes https://github.com/espressif/esp-idf/issues/858
2018-10-19 13:51:27 +00:00
/* Copyright 2018 Espressif Systems (Shanghai) PTE LTD
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
#ifndef _ESP_MB_MASTER_INTERFACE_H
#define _ESP_MB_MASTER_INTERFACE_H
#include <stdint.h> // for standard int types definition
#include <stddef.h> // for NULL and std defines
#include "soc/soc.h" // for BITN definitions
#include "esp_modbus_common.h" // for common types
#ifdef __cplusplus
extern "C" {
#endif
freemodbus: Fix bug with incorrect coils read mask Contains two different component folders per each implementation (serial_master and serial_slave) with concrete ports. Added common public api for master and slave and common interface for master and slave implementation. Add support of cmake system (added cmake files). Added sdkconfig.defaults files for slave and master modbus examples. Updated make file and KConfig for freemodbus component Update according to review and fix doxygen warnings Fix Doxyfile to pass documentation build Update headers and change interface file names as per review comments Merge branch feature/freemodbus_move_rs485_mode_control Update after review: The stack modbus folder updated to support master and slave ports together and moved into freemodbus/modbus Stack and port files updated to remove duplicated simbols Make file, KConfig and CMakeLists.txt updated to compile master and slave stacks, common interface and concrete implementations of ports Stack callback functions execute callbacks using interface pointer from concrete port implementation User can instantiate any of concrete port using common API (only one concrete port at a time) and it does not require to select port by KConfig Port pins and mode configuration moved into example files from port files to allow user select pins and port mode (customer request) Changes tested using pymodbus, ModbusPoll and communication between two boards Updated DoxyFile according to public include path Fix maximum instance size for slave (merge from master of customer issue) Fix critical section issue TW#28622 (change spin lock based critical section to semaphore) Move serial port files into component port folder for master and slave accordingly Fix example issue showed in the log when IO slave is not configured correctly Fix conflicts while merging from origin/master Fix errors handling in modbus controller interface + some final corrections according to review Update maximum allowed number of slaves in the network segment Fix bug with incorrect coils read mask Closes https://github.com/espressif/esp-idf/issues/858
2018-10-19 13:51:27 +00:00
/*!
* \brief Modbus descriptor table parameter type defines.
*/
typedef enum {
PARAM_TYPE_U8 = 0x00, /*!< Unsigned 8 */
PARAM_TYPE_U16 = 0x01, /*!< Unsigned 16 */
PARAM_TYPE_U32 = 0x02, /*!< Unsigned 32 */
PARAM_TYPE_FLOAT = 0x03, /*!< Float type */
PARAM_TYPE_ASCII = 0x04 /*!< ASCII type */
} mb_descr_type_t;
/*!
* \brief Modbus descriptor table parameter size in bytes.
*/
typedef enum {
PARAM_SIZE_U8 = 0x01, /*!< Unsigned 8 */
PARAM_SIZE_U16 = 0x02, /*!< Unsigned 16 */
PARAM_SIZE_U32 = 0x04, /*!< Unsigned 32 */
PARAM_SIZE_FLOAT = 0x04, /*!< Float size */
PARAM_SIZE_ASCII = 0x08, /*!< ASCII size */
PARAM_SIZE_ASCII24 = 0x18, /*!< ASCII24 size */
PARAM_MAX_SIZE
} mb_descr_size_t;
/*!
* \brief Modbus parameter options for description table
*/
typedef union {
struct {
int opt1; /*!< Parameter option1 */
int opt2; /*!< Parameter option2 */
int opt3; /*!< Parameter option3 */
};
struct {
int min; /*!< Parameter minimum value */
int max; /*!< Parameter maximum value */
int step; /*!< Step of parameter change tracking */
};
} mb_parameter_opt_t;
/**
* @brief Permissions for the characteristics
*/
typedef enum {
PAR_PERMS_READ = 1 << BIT0, /**< the characteristic of the device are readable */
PAR_PERMS_WRITE = 1 << BIT1, /**< the characteristic of the device are writable*/
PAR_PERMS_TRIGGER = 1 << BIT2, /**< the characteristic of the device are triggerable */
PAR_PERMS_READ_WRITE = PAR_PERMS_READ | PAR_PERMS_WRITE, /**< the characteristic of the device are readable & writable */
PAR_PERMS_READ_TRIGGER = PAR_PERMS_READ | PAR_PERMS_TRIGGER, /**< the characteristic of the device are readable & triggerable */
PAR_PERMS_WRITE_TRIGGER = PAR_PERMS_WRITE | PAR_PERMS_TRIGGER, /**< the characteristic of the device are writable & triggerable */
PAR_PERMS_READ_WRITE_TRIGGER = PAR_PERMS_READ_WRITE | PAR_PERMS_TRIGGER, /**< the characteristic of the device are readable & writable & triggerable */
} mb_param_perms_t;
/**
* @brief Characteristics descriptor type is used to describe characteristic and
* link it with Modbus parameters that reflect its data.
*/
typedef struct {
uint16_t cid; /*!< Characteristic cid */
const char* param_key; /*!< The key (name) of the parameter */
const char* param_units; /*!< The physical units of the parameter */
uint8_t mb_slave_addr; /*!< Slave address of device in the Modbus segment */
mb_param_type_t mb_param_type; /*!< Type of modbus parameter */
uint16_t mb_reg_start; /*!< This is the Modbus register address. This is the 0 based value. */
uint16_t mb_size; /*!< Size of mb parameter in registers */
uint16_t param_offset; /*!< Parameter name (OFFSET in the parameter structure) */
mb_descr_type_t param_type; /*!< Float, U8, U16, U32, ASCII, etc. */
mb_descr_size_t param_size; /*!< Number of bytes in the parameter. */
mb_parameter_opt_t param_opts; /*!< Parameter options used to check limits and etc. */
mb_param_perms_t access; /*!< Access permissions based on mode */
} mb_parameter_descriptor_t;
/**
* @brief Modbus register request type structure
*/
typedef struct {
uint8_t slave_addr; /*!< Modbus slave address */
uint8_t command; /*!< Modbus command to send */
uint16_t reg_start; /*!< Modbus start register */
uint16_t reg_size; /*!< Modbus number of registers */
} mb_param_request_t;
// Master interface public functions
/**
* @brief Initialize Modbus controller and stack
*
* @param[out] handler handler(pointer) to master data structure
* @param[in] port_type the type of port
* @return
* - ESP_OK Success
* - ESP_ERR_NO_MEM Parameter error
*/
esp_err_t mbc_master_init(mb_port_type_t port_type, void** handler);
/**
* @brief Destroy Modbus controller and stack
*
* @return
* - ESP_OK Success
* - ESP_ERR_INVALID_STATE Parameter error
*/
esp_err_t mbc_master_destroy(void);
/**
* @brief Start Modbus communication stack
*
* @return
* - ESP_OK Success
* - ESP_ERR_INVALID_ARG Modbus stack start error
*/
esp_err_t mbc_master_start(void);
/**
* @brief Set Modbus communication parameters for the controller
*
* @param comm_info Communication parameters structure.
*
* @return
* - ESP_OK Success
* - ESP_ERR_INVALID_ARG Incorrect parameter data
*/
esp_err_t mbc_master_setup(void* comm_info);
/***************************** Specific interface functions ********************************************
* Interface functions below provide basic methods to read/write access to slave devices in Modbus
* segment as well as API to read specific supported characteristics linked to Modbus parameters
* of devices in Modbus network.
*******************************************************************************************************/
/**
* @brief Assign parameter description table for Modbus controller interface.
*
* @param[in] descriptor pointer to parameter description table
* @param num_elements number of elements in the table
*
* @return
* - esp_err_t ESP_OK - set descriptor successfully
* - esp_err_t ESP_ERR_INVALID_ARG - invalid argument in function call
*/
esp_err_t mbc_master_set_descriptor(const mb_parameter_descriptor_t* descriptor, const uint16_t num_elements);
/**
* @brief Send data request as defined in parameter request, waits response
* from slave and returns status of command execution. This function provides standard way
* for read/write access to Modbus devices in the network.
*
* @param[in] request pointer to request structure of type mb_param_request_t
* @param[in] data_ptr pointer to data buffer to send or received data (dependent of command field in request)
*
* @return
* - esp_err_t ESP_OK - request was successful
* - esp_err_t ESP_ERR_INVALID_ARG - invalid argument of function
* - esp_err_t ESP_ERR_INVALID_RESPONSE - an invalid response from slave
* - esp_err_t ESP_ERR_TIMEOUT - operation timeout or no response from slave
* - esp_err_t ESP_ERR_NOT_SUPPORTED - the request command is not supported by slave
* - esp_err_t ESP_FAIL - slave returned an exception or other failure
*/
esp_err_t mbc_master_send_request(mb_param_request_t* request, void* data_ptr);
/**
* @brief Get information about supported characteristic defined as cid. Uses parameter description table to get
* this information. The function will check if characteristic defined as a cid parameter is supported
* and returns its description in param_info. Returns ESP_ERR_NOT_FOUND if characteristic is not supported.
*
* @param[in] cid characteristic id
* @param param_info pointer to pointer of characteristic data.
*
* @return
* - esp_err_t ESP_OK - request was successful and buffer contains the supported characteristic name
* - esp_err_t ESP_ERR_INVALID_ARG - invalid argument of function
* - esp_err_t ESP_ERR_NOT_FOUND - the characteristic (cid) not found
* - esp_err_t ESP_FAIL - unknown error during lookup table processing
*/
esp_err_t mbc_master_get_cid_info(uint16_t cid, const mb_parameter_descriptor_t** param_info);
/**
* @brief Read parameter from modbus slave device whose name is defined by name and has cid.
* The additional data for request is taken from parameter description (lookup) table.
*
* @param[in] cid id of the characteristic for parameter
* @param[in] name pointer into string name (key) of parameter (null terminated)
* @param[out] value pointer to data buffer of parameter
* @param[out] type parameter type associated with the name returned from parameter description table.
*
* @return
* - esp_err_t ESP_OK - request was successful and value buffer contains
* representation of actual parameter data from slave
* - esp_err_t ESP_ERR_INVALID_ARG - invalid argument of function
* - esp_err_t ESP_ERR_INVALID_RESPONSE - an invalid response from slave
* - esp_err_t ESP_ERR_INVALID_STATE - invalid state during data processing or allocation failure
* - esp_err_t ESP_ERR_TIMEOUT - operation timed out and no response from slave
* - esp_err_t ESP_ERR_NOT_SUPPORTED - the request command is not supported by slave
* - esp_err_t ESP_ERR_NOT_FOUND - the parameter is not found in the parameter description table
* - esp_err_t ESP_FAIL - slave returned an exception or other failure
*/
esp_err_t mbc_master_get_parameter(uint16_t cid, char* name, uint8_t* value, uint8_t *type);
/**
* @brief Set characteristic's value defined as a name and cid parameter.
* The additional data for cid parameter request is taken from master parameter lookup table.
*
* @param[in] cid id of the characteristic for parameter
* @param[in] name pointer into string name (key) of parameter (null terminated)
* @param[out] value pointer to data buffer of parameter (actual representation of json value field in binary form)
* @param[out] type pointer to parameter type associated with the name returned from parameter lookup table.
*
* @return
* - esp_err_t ESP_OK - request was successful and value was saved in the slave device registers
* - esp_err_t ESP_ERR_INVALID_ARG - invalid argument of function
* - esp_err_t ESP_ERR_INVALID_RESPONSE - an invalid response from slave during processing of parameter
* - esp_err_t ESP_ERR_INVALID_STATE - invalid state during data processing or allocation failure
* - esp_err_t ESP_ERR_TIMEOUT - operation timed out and no response from slave
* - esp_err_t ESP_ERR_NOT_SUPPORTED - the request command is not supported by slave
* - esp_err_t ESP_FAIL - slave returned an exception or other failure
*/
esp_err_t mbc_master_set_parameter(uint16_t cid, char* name, uint8_t* value, uint8_t *type);
#ifdef __cplusplus
}
#endif
freemodbus: Fix bug with incorrect coils read mask Contains two different component folders per each implementation (serial_master and serial_slave) with concrete ports. Added common public api for master and slave and common interface for master and slave implementation. Add support of cmake system (added cmake files). Added sdkconfig.defaults files for slave and master modbus examples. Updated make file and KConfig for freemodbus component Update according to review and fix doxygen warnings Fix Doxyfile to pass documentation build Update headers and change interface file names as per review comments Merge branch feature/freemodbus_move_rs485_mode_control Update after review: The stack modbus folder updated to support master and slave ports together and moved into freemodbus/modbus Stack and port files updated to remove duplicated simbols Make file, KConfig and CMakeLists.txt updated to compile master and slave stacks, common interface and concrete implementations of ports Stack callback functions execute callbacks using interface pointer from concrete port implementation User can instantiate any of concrete port using common API (only one concrete port at a time) and it does not require to select port by KConfig Port pins and mode configuration moved into example files from port files to allow user select pins and port mode (customer request) Changes tested using pymodbus, ModbusPoll and communication between two boards Updated DoxyFile according to public include path Fix maximum instance size for slave (merge from master of customer issue) Fix critical section issue TW#28622 (change spin lock based critical section to semaphore) Move serial port files into component port folder for master and slave accordingly Fix example issue showed in the log when IO slave is not configured correctly Fix conflicts while merging from origin/master Fix errors handling in modbus controller interface + some final corrections according to review Update maximum allowed number of slaves in the network segment Fix bug with incorrect coils read mask Closes https://github.com/espressif/esp-idf/issues/858
2018-10-19 13:51:27 +00:00
#endif // _ESP_MB_MASTER_INTERFACE_H