FreeDATA/test/util_beacon_2.py
2022-06-15 19:42:16 -04:00

159 lines
5.4 KiB
Python

#!/usr/bin/env python3
# -*- coding: utf-8 -*-
"""
Created on Wed Dec 23 07:04:24 2020
@author: DJ2LS
"""
import time
from pprint import pformat
from typing import Callable
import data_handler
import helpers
import modem
import sock
import static
import structlog
def t_setup(
mycall: str,
dxcall: str,
lowbwmode: bool,
t_transmit,
t_process_data,
tmp_path,
):
# Disable data_handler testmode - This is required to test a conversation.
data_handler.TESTMODE = False
modem.RXCHANNEL = tmp_path / "hfchannel2"
modem.TESTMODE = True
modem.TXCHANNEL = tmp_path / "hfchannel1"
static.HAMLIB_RADIOCONTROL = "disabled"
static.LOW_BANDWIDTH_MODE = lowbwmode
static.MYGRID = bytes("AA12aa", "utf-8")
static.RESPOND_TO_CQ = True
static.SSID_LIST = [0, 1, 2, 3, 4, 5, 6, 7, 8, 9]
mycallsign = helpers.callsign_to_bytes(mycall)
mycallsign = helpers.bytes_to_callsign(mycallsign)
static.MYCALLSIGN = mycallsign
static.MYCALLSIGN_CRC = helpers.get_crc_24(static.MYCALLSIGN)
dxcallsign = helpers.callsign_to_bytes(dxcall)
dxcallsign = helpers.bytes_to_callsign(dxcallsign)
static.DXCALLSIGN = dxcallsign
static.DXCALLSIGN_CRC = helpers.get_crc_24(static.DXCALLSIGN)
# Create the TNC
tnc = data_handler.DATA()
orig_rx_func = data_handler.DATA.process_data
data_handler.DATA.process_data = t_process_data
tnc.log = structlog.get_logger("station2_DATA")
# Limit the frame-ack timeout
tnc.time_list_low_bw = [1, 1, 1]
tnc.time_list_high_bw = [1, 1, 1]
tnc.time_list = [1, 1, 1]
# Limit number of retries
tnc.rx_n_max_retries_per_burst = 4
# Create the modem
t_modem = modem.RF()
orig_tx_func = modem.RF.transmit
modem.RF.transmit = t_transmit
t_modem.log = structlog.get_logger("station2_RF")
return tnc, orig_rx_func, orig_tx_func
def t_beacon2(
parent_pipe,
freedv_mode: str,
n_frames_per_burst: int,
mycall: str,
dxcall: str,
message: str,
lowbwmode: bool,
tmp_path,
):
log = structlog.get_logger("station2")
orig_tx_func: Callable
orig_rx_func: Callable
log.info("t_beacon2:", TMP_PATH=tmp_path)
def t_transmit(self, mode, repeats: int, repeat_delay: int, frames: bytearray):
"""'Wrap' RF.transmit function to extract the arguments."""
nonlocal orig_tx_func, parent_pipe
t_frames = frames
parent_pipe.send(t_frames)
# log.info("S2 TX: ", frames=t_frames)
for item in t_frames:
frametype = int.from_bytes(item[:1], "big") # type: ignore
log.info("S2 TX: ", TX=frametype)
# Apologies for the Python "magic." "orig_func" is a pointer to the
# original function captured before this one was put in place.
orig_tx_func(self, mode, repeats, repeat_delay, frames) # type: ignore
def t_process_data(self, bytes_out, freedv, bytes_per_frame: int):
"""'Wrap' DATA.process_data function to extract the arguments."""
nonlocal orig_rx_func, parent_pipe
t_bytes_out = bytes(bytes_out)
parent_pipe.send(t_bytes_out)
log.debug(
"S2 RX: ",
bytes_out=t_bytes_out,
bytes_per_frame=bytes_per_frame,
)
frametype = int.from_bytes(t_bytes_out[:1], "big")
log.info("S2 RX: ", RX=frametype)
# Apologies for the Python "magic." "orig_func" is a pointer to the
# original function captured before this one was put in place.
orig_rx_func(self, bytes_out, freedv, bytes_per_frame) # type: ignore
tnc, orig_rx_func, orig_tx_func = t_setup(
mycall, dxcall, lowbwmode, t_transmit, t_process_data, tmp_path
)
log.info("t_beacon2:", RXCHANNEL=modem.RXCHANNEL)
log.info("t_beacon2:", TXCHANNEL=modem.TXCHANNEL)
# Assure the test completes.
timeout = time.time() + 20 # 25
# Compare with the string conversion instead of repeatedly dumping
# the queue to an object for comparisons.
# while (
# '"arq":"transmission","status":"received"' not in str(sock.SOCKET_QUEUE.queue)
# or static.ARQ_STATE
# ):
while '"beacon":"received"' not in str(sock.SOCKET_QUEUE.queue):
# while '"cq":"received"' not in str(sock.SOCKET_QUEUE.queue):
if time.time() > timeout:
log.warning("station2 TIMEOUT", first=True)
break
time.sleep(0.5)
log.info("station2, first", arq_state=pformat(static.ARQ_STATE))
# Allow enough time for this side to receive the disconnect frame.
timeout = time.time() + 15 # 20
while '"arq":"session","status":"close"' not in str(sock.SOCKET_QUEUE.queue):
if time.time() > timeout:
log.error("station2", TIMEOUT=True)
break
time.sleep(0.5)
log.info("station2", arq_state=pformat(static.ARQ_STATE))
# log.info("S2 DQT: ", DQ_Tx=pformat(tnc.data_queue_transmit.queue))
# log.info("S2 DQR: ", DQ_Rx=pformat(tnc.data_queue_received.queue))
# log.info("S2 Socket: ", socket_queue=pformat(sock.SOCKET_QUEUE.queue))
# assert '"arq":"transmission","status":"received"' in str(sock.SOCKET_QUEUE.queue)
assert '"beacon":"received"' in str(sock.SOCKET_QUEUE.queue)
# assert '"cq":"received"' in str(sock.SOCKET_QUEUE.queue)
# assert '"qrv":"transmitting"' in str(sock.SOCKET_QUEUE.queue)
assert '"arq":"session","status":"close"' in str(sock.SOCKET_QUEUE.queue)
log.error("station2: Exiting!")