FreeDATA/test/util_tnc_IRS.py

106 lines
3.1 KiB
Python

# -*- coding: utf-8 -*-
"""
Receive-side station emulator for connect frame tests over a high quality simulated audio channel.
Near end-to-end test for sending / receiving connection control frames through the
TNC and modem and back through on the other station. Data injection initiates from the
queue used by the daemon process into and out of the TNC.
Invoked from test_tnc.py.
@author: N2KIQ
"""
import signal
import sys
import time
from typing import Callable
import structlog
sys.path.insert(0, "../modem")
import data_handler
import helpers
import modem
import sock
import static
IRS_original_arq_cleanup: Callable
MESSAGE: str
log = structlog.get_logger("util_tnc_IRS")
def irs_arq_cleanup():
"""Replacement for modem.arq_cleanup to detect when to exit process."""
log.info(
"irs_arq_cleanup", socket_queue=sock.SOCKET_QUEUE.queue, message=MESSAGE.lower()
)
if '"arq":"transmission","status":"stopped"' in str(sock.SOCKET_QUEUE.queue):
# log.info("irs_arq_cleanup", socket_queue=sock.SOCKET_QUEUE.queue)
time.sleep(2)
if f'"{MESSAGE.lower()}":"receiving"' not in str(
sock.SOCKET_QUEUE.queue
) and f'"{MESSAGE.lower()}":"received"' not in str(sock.SOCKET_QUEUE.queue):
print(f"{MESSAGE} was not received.")
log.info("irs_arq_cleanup", socket_queue=sock.SOCKET_QUEUE.queue)
# sys.exit does not terminate threads, and os_exit doesn't allow coverage collection.
signal.raise_signal(signal.SIGKILL)
signal.raise_signal(signal.SIGTERM)
IRS_original_arq_cleanup()
def t_arq_irs(*args):
# pylint: disable=global-statement
global IRS_original_arq_cleanup, MESSAGE
MESSAGE = args[0]
tmp_path = args[1]
sock.log = structlog.get_logger("util_tnc_IRS_sock")
# enable testmode
data_handler.TESTMODE = True
modem.RXCHANNEL = tmp_path / "hfchannel2"
modem.TESTMODE = True
modem.TXCHANNEL = tmp_path / "hfchannel1"
static.HAMLIB_RADIOCONTROL = "disabled"
static.RESPOND_TO_CQ = True
log.info("t_arq_irs:", RXCHANNEL=modem.RXCHANNEL)
log.info("t_arq_irs:", TXCHANNEL=modem.TXCHANNEL)
mycallsign = bytes("DN2LS-2", "utf-8")
mycallsign = helpers.callsign_to_bytes(mycallsign)
static.MYCALLSIGN = helpers.bytes_to_callsign(mycallsign)
static.MYCALLSIGN_CRC = helpers.get_crc_24(static.MYCALLSIGN)
static.MYGRID = bytes("AA12aa", "utf-8")
static.SSID_LIST = [0, 1, 2, 3, 4, 5, 6, 7, 8, 9]
# start data handler
tnc = data_handler.DATA()
tnc.log = structlog.get_logger("util_tnc_IRS_DATA")
# Inject a way to exit the TNC infinite loop
IRS_original_arq_cleanup = tnc.arq_cleanup
tnc.arq_cleanup = irs_arq_cleanup
# start modem
t_modem = modem.RF()
t_modem.log = structlog.get_logger("util_tnc_IRS_RF")
# Set timeout
timeout = time.time() + 15
while time.time() < timeout:
time.sleep(0.1)
log.warning("queue:", queue=sock.SOCKET_QUEUE.queue)
assert not "TIMEOUT!"
if __name__ == "__main__":
print("This cannot be run as an application.")
sys.exit(1)