cleanup and improved logging

This commit is contained in:
dj2ls 2022-09-08 15:47:23 +02:00
parent b3595fb033
commit dba7f63de8

View file

@ -278,15 +278,15 @@ class DATA:
_valid1, _ = helpers.check_callsign(self.mycallsign, bytes(bytes_out[1:4]))
_valid2, _ = helpers.check_callsign(self.mycallsign, bytes(bytes_out[2:5]))
if (
_valid1
or _valid2
or frametype
in [
FR_TYPE.CQ.value,
FR_TYPE.QRV.value,
FR_TYPE.PING.value,
FR_TYPE.BEACON.value,
]
_valid1
or _valid2
or frametype
in [
FR_TYPE.CQ.value,
FR_TYPE.QRV.value,
FR_TYPE.PING.value,
FR_TYPE.BEACON.value,
]
):
# CHECK IF FRAMETYPE IS BETWEEN 10 and 50 ------------------------
@ -335,11 +335,11 @@ class DATA:
)
def enqueue_frame_for_tx(
self,
frame_to_tx: bytearray,
c2_mode=FREEDV_MODE.datac0.value,
copies=1,
repeat_delay=0,
self,
frame_to_tx: bytearray,
c2_mode=FREEDV_MODE.datac0.value,
copies=1,
repeat_delay=0,
) -> None:
"""
Send (transmit) supplied frame to TNC
@ -473,7 +473,7 @@ class DATA:
self.enqueue_frame_for_tx(disconnection_frame, copies=5, repeat_delay=250)
def arq_data_received(
self, data_in: bytes, bytes_per_frame: int, snr: float, freedv
self, data_in: bytes, bytes_per_frame: int, snr: float, freedv
) -> None:
"""
Args:
@ -571,8 +571,8 @@ class DATA:
# if we find data, replace it at this position with the new data and strip it
if get_position >= 0:
static.RX_FRAME_BUFFER = static.RX_FRAME_BUFFER[
: search_position + get_position
]
: search_position + get_position
]
static.RX_FRAME_BUFFER += temp_burst_buffer
self.log.warning(
"[TNC] ARQ | RX | replacing existing buffer data",
@ -587,9 +587,9 @@ class DATA:
# Check if we didn't receive a BOF and EOF yet to avoid sending
# ack frames if we already received all data
if (
not self.rx_frame_bof_received
and not self.rx_frame_eof_received
and data_in.find(self.data_frame_eof) < 0
not self.rx_frame_bof_received
and not self.rx_frame_eof_received
and data_in.find(self.data_frame_eof) < 0
):
self.frame_received_counter += 1
@ -649,8 +649,8 @@ class DATA:
if bof_position >= 0:
payload = static.RX_FRAME_BUFFER[
bof_position + len(self.data_frame_bof) : eof_position
]
bof_position + len(self.data_frame_bof): eof_position
]
frame_length = int.from_bytes(payload[4:8], "big") # 4:8 4bytes
static.TOTAL_BYTES = frame_length
compression_factor = int.from_bytes(payload[8:9], "big") # 4:8 4bytes
@ -662,9 +662,9 @@ class DATA:
)
if (
bof_position >= 0
and eof_position > 0
and None not in static.RX_BURST_BUFFER
bof_position >= 0
and eof_position > 0
and None not in static.RX_BURST_BUFFER
):
self.log.debug(
"[TNC] arq_data_received:",
@ -676,8 +676,8 @@ class DATA:
# Extract raw data from buffer
payload = static.RX_FRAME_BUFFER[
bof_position + len(self.data_frame_bof) : eof_position
]
bof_position + len(self.data_frame_bof): eof_position
]
# Get the data frame crc
data_frame_crc = payload[:4] # 0:4 = 4 bytes
# Get the data frame length
@ -850,12 +850,12 @@ class DATA:
# Assemble the data frame
data_out = (
self.data_frame_bof
+ frame_payload_crc
+ frame_total_size
+ compression_factor
+ data_out
+ self.data_frame_eof
self.data_frame_bof
+ frame_payload_crc
+ frame_total_size
+ compression_factor
+ data_out
+ self.data_frame_eof
)
# Initial bufferposition is 0
@ -924,7 +924,7 @@ class DATA:
else:
extended_data_out = data_out[bufferposition:]
extended_data_out += bytes([0]) * (
payload_per_frame - len(extended_data_out) - len(arqheader)
payload_per_frame - len(extended_data_out) - len(arqheader)
)
frame = arqheader + extended_data_out
@ -951,10 +951,10 @@ class DATA:
# burstacktimeout = time.time() + BURST_ACK_TIMEOUT_SECONDS + 100
while static.ARQ_STATE and not (
self.burst_ack
or self.burst_nack
or self.rpt_request_received
or self.data_frame_ack_received
self.burst_ack
or self.burst_nack
or self.rpt_request_received
or self.data_frame_ack_received
):
time.sleep(0.01)
@ -1125,7 +1125,7 @@ class DATA:
)
def frame_ack_received(
self, data_in: bytes # pylint: disable=unused-argument
self, data_in: bytes # pylint: disable=unused-argument
) -> None:
"""Received an ACK for a transmitted frame"""
# Process data only if we are in ARQ and BUSY state
@ -1145,7 +1145,7 @@ class DATA:
self.arq_session_last_received = int(time.time())
def frame_nack_received(
self, data_in: bytes # pylint: disable=unused-argument
self, data_in: bytes # pylint: disable=unused-argument
) -> None:
"""
Received a NACK for a transmitted frame
@ -1202,8 +1202,8 @@ class DATA:
missing_area = bytes(data_in[3:12]) # 1:9
for i in range(0, 6, 2):
if not missing_area[i : i + 2].endswith(b"\x00\x00"):
missing = missing_area[i : i + 2]
if not missing_area[i: i + 2].endswith(b"\x00\x00"):
missing = missing_area[i: i + 2]
self.rpt_request_buffer.insert(0, missing)
############################################################################################################
@ -1467,12 +1467,12 @@ class DATA:
# ARQ DATA CHANNEL HANDLER
##########################################################################################################
def open_dc_and_transmit(
self,
data_out: bytes,
mode: int,
n_frames_per_burst: int,
transmission_uuid: str,
mycallsign,
self,
data_out: bytes,
mode: int,
n_frames_per_burst: int,
transmission_uuid: str,
mycallsign,
) -> bool:
"""
Open data channel and transmit data
@ -1518,7 +1518,7 @@ class DATA:
return False
def arq_open_data_channel(
self, mode: int, n_frames_per_burst: int, mycallsign
self, mode: int, n_frames_per_burst: int, mycallsign
) -> bool:
"""
Open an ARQ data channel.
@ -1567,7 +1567,7 @@ class DATA:
+ "]>> <<["
+ str(static.DXCALLSIGN, "UTF-8")
+ "]",
attempt=f"{str(attempt+1)}/{str(self.data_channel_max_retries)}",
attempt=f"{str(attempt + 1)}/{str(self.data_channel_max_retries)}",
)
self.enqueue_frame_for_tx(connection_frame)
@ -1680,12 +1680,19 @@ class DATA:
self.time_list = self.time_list_low_bw
self.snr_list = self.snr_list_low_bw
# get mode which fits to given SNR
# initially set speed_level 0 in case of really bad SNR and no matching mode
self.speed_level = 0
for i in range(len(self.mode_list)):
if static.SNR >= self.snr_list[i]:
self.speed_level = i
self.log.debug("[TNC] calculated speed level", speed_level=self.speed_level, given_snr=static.SNR, min_snr=self.snr_list[self.speed_level])
self.log.debug(
"[TNC] calculated speed level",
speed_level=self.speed_level,
given_snr=static.SNR,
min_snr=self.snr_list[self.speed_level],
)
# Update modes we are listening to
self.set_listening_modes(self.mode_list[self.speed_level])
@ -1784,7 +1791,7 @@ class DATA:
# set speed level from session opener frame which is selected by SNR measurement
self.speed_level = int.from_bytes(bytes(data_in[8:9]), "big")
self.log.debug("[TNC] speed level selected for given SNR", speed_level=self.speed_level)
#self.speed_level = len(self.mode_list) - 1
# self.speed_level = len(self.mode_list) - 1
helpers.add_to_heard_stations(
static.DXCALLSIGN,
@ -1983,7 +1990,7 @@ class DATA:
self.arq_cleanup()
def received_stop_transmission(
self, data_in: bytes
self, data_in: bytes
) -> None: # pylint: disable=unused-argument
"""
Received a transmission stop
@ -2017,9 +2024,9 @@ class DATA:
time.sleep(0.5)
while static.BEACON_STATE:
if (
not static.ARQ_SESSION
and not self.arq_file_transfer
and not static.BEACON_PAUSE
not static.ARQ_SESSION
and not self.arq_file_transfer
and not static.BEACON_PAUSE
):
self.send_data_to_socket_queue(
freedata="tnc-message",
@ -2046,9 +2053,9 @@ class DATA:
interval_timer = time.time() + self.beacon_interval
while (
time.time() < interval_timer
and static.BEACON_STATE
and not static.BEACON_PAUSE
time.time() < interval_timer
and static.BEACON_STATE
and not static.BEACON_PAUSE
):
time.sleep(0.01)
@ -2226,7 +2233,7 @@ class DATA:
# ------------ CALUCLATE TRANSFER RATES
def calculate_transfer_rate_rx(
self, rx_start_of_transmission: float, receivedbytes: int
self, rx_start_of_transmission: float, receivedbytes: int
) -> list:
"""
Calculate transfer rate for received data
@ -2245,9 +2252,9 @@ class DATA:
static.ARQ_TRANSMISSION_PERCENT = min(
int(
(
receivedbytes
* static.ARQ_COMPRESSION_FACTOR
/ (static.TOTAL_BYTES)
receivedbytes
* static.ARQ_COMPRESSION_FACTOR
/ (static.TOTAL_BYTES)
)
* 100
),
@ -2290,7 +2297,7 @@ class DATA:
static.TOTAL_BYTES = 0
def calculate_transfer_rate_tx(
self, tx_start_of_transmission: float, sentbytes: int, tx_buffer_length: int
self, tx_start_of_transmission: float, sentbytes: int, tx_buffer_length: int
) -> list:
"""
Calculate transfer rate for transmission
@ -2440,16 +2447,16 @@ class DATA:
# TODO: We need to redesign this part for cleaner state handling
# Return if not ARQ STATE and not ARQ SESSION STATE as they are different use cases
if (
not static.ARQ_STATE
and static.ARQ_SESSION_STATE != "connected"
or not self.is_IRS
not static.ARQ_STATE
and static.ARQ_SESSION_STATE != "connected"
or not self.is_IRS
):
return
# We want to reach this state only if connected ( == return above not called )
if (
self.data_channel_last_received + self.time_list[self.speed_level]
<= time.time()
self.data_channel_last_received + self.time_list[self.speed_level]
<= time.time()
):
self.log.warning(
"[TNC] Frame timeout",
@ -2490,8 +2497,8 @@ class DATA:
if static.ARQ_STATE and static.TNC_STATE == "BUSY":
time.sleep(0.01)
if (
self.data_channel_last_received + self.transmission_timeout
> time.time()
self.data_channel_last_received + self.transmission_timeout
> time.time()
):
time.sleep(0.01)
# print(self.data_channel_last_received + self.transmission_timeout - time.time())
@ -2520,9 +2527,9 @@ class DATA:
ARQ SESSION
"""
if (
static.ARQ_SESSION
and static.TNC_STATE == "BUSY"
and not self.arq_file_transfer
static.ARQ_SESSION
and static.TNC_STATE == "BUSY"
and not self.arq_file_transfer
):
if self.arq_session_last_received + self.arq_session_timeout > time.time():
time.sleep(0.01)
@ -2549,10 +2556,10 @@ class DATA:
while True:
time.sleep(0.01)
if (
static.ARQ_SESSION
and self.IS_ARQ_SESSION_MASTER
and static.ARQ_SESSION_STATE == "connected"
and not self.arq_file_transfer
static.ARQ_SESSION
and self.IS_ARQ_SESSION_MASTER
and static.ARQ_SESSION_STATE == "connected"
and not self.arq_file_transfer
):
time.sleep(1)