Update Detailed Control Menu

Ray Jones 2019-01-23 09:09:41 +00:00
parent 6804b4f6af
commit 6411ec4806

@ -32,7 +32,7 @@ The heat exchanger temperature being reported in the right hand side "thermomete
![ScreenDetailedIgnited](uploads/646d40e69e4aad7eaf434301110684e1/ScreenDetailedIgnited.jpg) ![ScreenDetailedIgnited](uploads/646d40e69e4aad7eaf434301110684e1/ScreenDetailedIgnited.jpg)
Once the body temperature rises over about 65 degrees or so, the glow plug is shut down, all the while the fuel pump and fan speeds are progressively increased until at full speed. Once the body temperature rises over about 65 degrees or so, the glow plug is shut down, all the while the fuel pump and fan speeds are progressively increased until at full speed.
The heater runs in this state for quite a few minutes getting the internals nice and hot. The heater runs in this state for quite a few minutes getting the internals nice and hot.
![ScreenDetailedIgnitedGlowOff](uploads/e3eef473f0547203b173befd5a4b5ca7/ScreenDetailedIgnitedGlowOff.jpg) ![ScreenDetailedIgnitedGlowOff](uploads/e3eef473f0547203b173befd5a4b5ca7/ScreenDetailedIgnitedGlowOff.jpg)
After running at full speed for a while, the heater transitions to the running state, and now obeys the desired setting being ewither a thermostat setting, or a fixed heat demand. After running at full speed for a while, the heater transitions to the running state, and now obeys the desired setting being ewither a thermostat setting, or a fixed heat demand.