@ -19,8 +19,8 @@ Shortly thereafter, the fan will begin spinning, and the glow plug will be gentl
It takes about a minute for the glow plug to receive full power, at which point the pump then starts:
![ScreenDetailedPumpOn](uploads/55de740283cf89c755995ef72fb98e7d/ScreenDetailedPumpOn.jpg)
the pump starts at a slow speed and steadily rises, along with fan speed to get the heater ignited.
Ignition tends to be sensed once the body temperature of the heat exchanger has risen by about 5-10 degrees Celcius:
The pump starts at a slow speed and steadily rises, along with fan speed to get the heater ignited.
Ignition tends to be sensed once the body temperature of the heat exchanger has risen by about 5-10 degC:
![ScreenDetailedIgnited](uploads/646d40e69e4aad7eaf434301110684e1/ScreenDetailedIgnited.jpg)
Once the body temperature rises over about 65 degrees or so, the glow plug is shut down, all the while the fuel pump is progressively starts running faster until at full speed.