Update Detailed Control Menu
parent
a0f51ac3cd
commit
0f6784d879
1 changed files with 3 additions and 3 deletions
|
@ -3,7 +3,7 @@
|
||||||
The detailed control menu allows the operation of the heater to be monitored in close detail.
|
The detailed control menu allows the operation of the heater to be monitored in close detail.
|
||||||
Here the actual pump speed, fan RPM, heat exchanger temperature and glow plug activity can be observed.
|
Here the actual pump speed, fan RPM, heat exchanger temperature and glow plug activity can be observed.
|
||||||
|
|
||||||
The heater can be turned on or off by holding the Centre keypad button.
|
The heater can be turned on or off by holding the Centre keypad button.
|
||||||
The desired temperature, or fixed heat demand can be altered by pressing the Up / Down keys.
|
The desired temperature, or fixed heat demand can be altered by pressing the Up / Down keys.
|
||||||
|
|
||||||
With the heater idle, the menu will look something like below:
|
With the heater idle, the menu will look something like below:
|
||||||
|
@ -19,8 +19,8 @@ Shortly thereafter, the fan will begin spinning, and the glow plug will be gentl
|
||||||
It takes about a minute for the glow plug to receive full power, at which point the pump then starts:
|
It takes about a minute for the glow plug to receive full power, at which point the pump then starts:
|
||||||
![ScreenDetailedPumpOn](uploads/55de740283cf89c755995ef72fb98e7d/ScreenDetailedPumpOn.jpg)
|
![ScreenDetailedPumpOn](uploads/55de740283cf89c755995ef72fb98e7d/ScreenDetailedPumpOn.jpg)
|
||||||
|
|
||||||
the pump starts at a slow speed and steadily rises, along with fan speed to get the heater ignited.
|
The pump starts at a slow speed and steadily rises, along with fan speed to get the heater ignited.
|
||||||
Ignition tends to be sensed once the body temperature of the heat exchanger has risen by about 5-10 degrees Celcius:
|
Ignition tends to be sensed once the body temperature of the heat exchanger has risen by about 5-10 degC:
|
||||||
![ScreenDetailedIgnited](uploads/646d40e69e4aad7eaf434301110684e1/ScreenDetailedIgnited.jpg)
|
![ScreenDetailedIgnited](uploads/646d40e69e4aad7eaf434301110684e1/ScreenDetailedIgnited.jpg)
|
||||||
|
|
||||||
Once the body temperature rises over about 65 degrees or so, the glow plug is shut down, all the while the fuel pump is progressively starts running faster until at full speed.
|
Once the body temperature rises over about 65 degrees or so, the glow plug is shut down, all the while the fuel pump is progressively starts running faster until at full speed.
|
||||||
|
|
Loading…
Reference in a new issue