ESP32_ChinaDieselHeater_Con.../src/Protocol/SmartError.h
Ray Jones 97f3433158 BIG FIXES: External thermostat start denied if internal thermostat too high
Pump priming from web page only worked once - was because prime command was never released from heater.
2020-05-06 10:41:26 +10:00

42 lines
1.4 KiB
C++

/*
* This file is part of the "bluetoothheater" distribution
* (https://gitlab.com/mrjones.id.au/bluetoothheater)
*
* Copyright (C) 2018 Ray Jones <ray@mrjones.id.au>
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <https://www.gnu.org/licenses/>.
*
*/
#include "Protocol.h"
class CSmartError {
uint8_t _prevRunState;
uint8_t _prevPumpHz;
uint8_t _Error;
bool _bInhibit;
void _monitorPriming(uint8_t runState, uint8_t pumpHz);
void _monitor(uint8_t runstate);
public:
CSmartError();
void reset();
void inhibit(bool reseterror=false);
void monitor(const CProtocol& heaterFrame);
int checkVolts(float volts, float plugI, bool throwfault=true); // 0 = OK, 1 = within 0.5V of LVC, 2 = under LVC
int checkfuelUsage(bool throwfault=true);
uint8_t getError();
};
extern CSmartError SmartError;