Commit graph

8 commits

Author SHA1 Message Date
Ray Jones 4986a4d741 Assortment of tweaks and fixes
New Features:
GPIO "Run" status output (not standby)
RSSI of STA connection
STA gatewayIP
Only run as "active" controller when changes to fuel mixture etc for a short while.
Timed moderation added for frequently changing JSON vars
Altitude & Humidity via JSON
JSON reboot (mainly for MQTT clients)

Bug Fixes:
Cyclic not enabled when frost start
LVC holdoff added for "starting car" situation
Better handling of string and float NV Storage defaults
FrostRise limits  1-30 now 0-30
Handle spaces in SPIFFS file uploads
2020-03-23 16:54:15 +11:00
Ray Jones 06d78860ca Bug fix: Factory default would not save 2020-01-15 07:55:57 +11:00
Ray Jones 7e1a4940ac Added BME280 humidity and altitude information
Can start heater if high humidity
Altitude reported to heater per BMP180 in OEM controllers.
lowered min Hz limit to 500
2020-01-13 19:48:32 +11:00
Ray Jones 88cf18bfcf BUG FIX: insufficient wait time after OEM controller data packet, bad calc of start time :-( 2020-01-07 12:30:13 +11:00
Ray Jones c9298656fa Tx gate now terminated via a HW timer callback. Using max priority task for SW watchdog. 2019-11-22 21:30:45 +11:00
Ray Jones 6fb7b9d608 Added UIEditScreen class to standardise the save&confirm behaviour.
Bug fix in body temperature sensor < 0
2019-11-21 19:25:14 +11:00
Ray Jones 10db95733f Added external thermostat via GPIO in 2. Want to change how GPIO pins are defined.
Modded code to only allow single DS18B20 - getting funny ROM SEARCH lock ups...
Set mini temp sample interval to 750ms, as per data sheet for 12bit DS18B20
2019-08-07 18:59:30 +10:00
Ray Jones 8ebf6dbf3e Refactored directory hierarchy to regain some linker command line space in PIO 2019-07-23 22:32:36 +10:00
Renamed from src/Afterburner/src/Protocol/TxManage.cpp (Browse further)