Commit graph

64 commits

Author SHA1 Message Date
Ray Jones 4eddcd0f1e STA only mode
Fixed MQTT topic prefix
2020-04-08 07:51:52 +10:00
Ray Jones 9c100f1954 Added Fuel Reset GPIO input option 2020-03-31 19:46:25 +11:00
Ray Jones 8ec438e02a Added excess fuel usage shutdown feature 2020-03-30 16:17:54 +11:00
Ray Jones 8b8aaf0024 Timer Temperature support added
Desired temperature requests are now managed via TimerManager to allow timer override of desired temperature.
Bug fix: crash checking for new firmware if no STA connection
Suppression of GPIO JSON if no or limited GPIO capability is installed.
2020-03-29 13:59:13 +11:00
Ray Jones 87b1704335 Added OLED and JSON Web Content Update functionality 2020-03-25 20:28:12 +11:00
Ray Jones 4986a4d741 Assortment of tweaks and fixes
New Features:
GPIO "Run" status output (not standby)
RSSI of STA connection
STA gatewayIP
Only run as "active" controller when changes to fuel mixture etc for a short while.
Timed moderation added for frequently changing JSON vars
Altitude & Humidity via JSON
JSON reboot (mainly for MQTT clients)

Bug Fixes:
Cyclic not enabled when frost start
LVC holdoff added for "starting car" situation
Better handling of string and float NV Storage defaults
FrostRise limits  1-30 now 0-30
Handle spaces in SPIFFS file uploads
2020-03-23 16:54:15 +11:00
Ray Jones 3ca3e633ae Added getch the to our TelnetSpy overload. This adds the logic to add a LF if only CR is sent by a terminal package 2020-01-15 17:52:43 +11:00
Ray Jones 7e1a4940ac Added BME280 humidity and altitude information
Can start heater if high humidity
Altitude reported to heater per BMP180 in OEM controllers.
lowered min Hz limit to 500
2020-01-13 19:48:32 +11:00
Ray Jones 194cc08ac9 Case Sensitive issue "ABmqtt"/"ABMqtt" -> "ABMQTT.h" 2020-01-05 08:46:46 +11:00
Ray Jones f5d72e2ac8 Using asyncHTTPrequest for version update check, synchronous method for actual update.
Released and tagged as V3.1.7.4 BETA
2020-01-04 18:13:40 +11:00
Ray Jones 69155f8e45 Stabilise using AsyncTCP to scrape FOTA JSON file.
Need to establish WTF "closed_slots" in AsyncTCP are all about, especially the bad indexes that fly about leading to LWIP crashes.
2019-12-15 17:58:11 +11:00
Ray Jones c76490481d Bug fixes:
Telnet spy would not work in AP only mode
LVC would not allow start when in warning mode, and LVC warning always started at 12/24V
Added "No GPIO" option for new boards with C6 fitted as a 0R
2019-12-06 21:12:56 +11:00
Ray Jones 6fb7b9d608 Added UIEditScreen class to standardise the save&confirm behaviour.
Bug fix in body temperature sensor < 0
2019-11-21 19:25:14 +11:00
Ray Jones 7081391f63 Added core frost functionality 2019-11-01 09:24:58 +11:00
Ray Jones f2af9c3fda Added under/over temperature threshold for GPIO outputs 2019-10-30 21:48:25 +11:00
Ray Jones 96b3cecdb0 Updated AsyncTCP library - had bad DNS handling if name not resolvable (null pointer dereference) 2019-10-28 17:32:16 +11:00
Ray Jones b1cee63ec3 Added ABTelnetSpy derived class modules 2019-10-27 16:37:12 +11:00
Ray Jones 5efce879ce Quietened down debug reporting when MQTT or Bluetooth debug menus active.
Single debug report of one wire searches (init only typ.)
2019-10-27 14:25:40 +11:00
Ray Jones 8893abb575 tidy up 2019-10-20 20:19:27 +11:00
Ray Jones 2e25ad3da4 Fixed role ordering in NV for DS18B20 probe offsets
Replaced ` with clean degree symbol in standard font & arial 8
Removed temp offset from fuel cal screen
GUI alignment tweaks to avoid cutoffs
Better handling of single DS18B20 with BME280
Added bounds limits to Exponential Mean
Sorted inheritance from CSensor properly
2019-10-19 09:58:19 +11:00
Ray Jones aabe6a54b3 Stabilised BME280 with DS18B20 coexistence 2019-10-18 12:55:16 +11:00
Ray Jones ab246244c9 Merge branch 'Branch_V3BoardDetect' 2019-09-25 19:39:02 +10:00
Ray Jones af34331401 Dig Only V3 PCB, Fixed Hz setting reporting bug fix 2019-09-25 19:38:19 +10:00
Ray Jones 112628f103 Tidy up 2019-09-25 17:27:43 +10:00
Ray Jones 573ebf3e3b Added auto save of single DS18B20 serial number 2019-09-22 14:46:39 +10:00
Ray Jones 8fb1981552 Added Temp Probe selection screen, mapping sensors to user preferences 2019-09-22 09:03:42 +10:00
Ray Jones de9417ff73 Tidied JSON/MQTT topic command decode into UtilClasses.cpp 2019-09-21 09:58:51 +10:00
Ray Jones 6e86571a19 Merged branch 'VerboseMQTTout'
Resolved Conflicts:
	src/Afterburner.cpp
	src/Utility/BTC_JSON.cpp
2019-09-21 08:11:36 +10:00
Ray Jones bf537d1ac5 MQTT can now accept any cmd topic that matches the JSON names 2019-09-20 23:00:27 +10:00
Ray Jones c51b18dd36 Added password hold option 2019-09-17 20:07:57 +10:00
Ray Jones 3a70970356 Added menu mode selection menu 2019-09-17 08:30:49 +10:00
Ray Jones f93e5d7628 Add basic menu Modes 2019-09-15 12:51:51 +10:00
Ray Jones ac5fdc5dfd V3.1.2 -
AM/PM selection in clock setup menu.
Extra MQTT JSON IDs added.

Filtered No Heater JSON.
2019-09-08 10:14:36 +10:00
Ray Jones 583a4881cd Added AM/PM annunciators to clock for 12hr mode
Added last will to MQTT connection
Condensed no heater timeouts with default screen
2019-09-07 23:48:46 +10:00
Ray Jones 9fbb6e8dfc Shifted MQTT telnet setup into a separate module.
Fixed addCRC script for > V3 python
2019-09-07 18:28:21 +10:00
Ray Jones 77dada9d6b BUG FIX: Fuel gauge reset via web page
NEW FEATURE: MQTT status screen
2019-09-04 20:59:01 +10:00
Ray Jones 8a237059fd Added JSON driven watchdog 2019-09-01 17:35:12 +10:00
Ray Jones 61e246f6f1 telnet menu to setup MQTT. JSON now pushed over MQTT - typ. topic name: Afterburner/JSONout 2019-08-31 17:34:56 +10:00
Ray Jones 253bc3f728 Added MQTT topic for controller to NV store.
Found PubSubClient is blocking, causing WD reboots
2019-08-30 20:08:54 +10:00
Ray Jones c79522233c Added Stop function to GPIO input #1 (eg CO sensor with Ext Thermostat 2019-08-27 20:35:21 +10:00
Ray Jones 08a39a26f7 Added countdown to detailed GUI for external thermostat shutdown feature 2019-08-27 06:13:01 +10:00
Ray Jones e7bac339b5 Implemented functionality to start & stop heater according to external thermostat input 2019-08-26 06:37:41 +10:00
Ray Jones f5a8c3c11e BUG FIX: GPIO2 set for external thermostat sent dT as the Greek 'd' in the JSON - BAD - broke websocket 2019-08-19 05:33:07 +10:00
Ray Jones 79b6c06a2a Added AP SSID/password configuration via debug port 2019-08-10 21:45:28 +10:00
Ray Jones d7e083b837 Board detect bug fix. New icons for GPIO setup/status 2019-08-10 15:57:46 +10:00
Ray Jones 4873fa8c71 Split GPIO so each pin's function is defined individually.
Adjusted DS18B20 timing to match Maxim's recommended values.
2019-08-09 06:13:02 +10:00
Ray Jones 48a0254f13 Can now define the operation mode for each GPIO line individually.
Need to test actual functionality, GUI OK.
2019-08-07 22:04:20 +10:00
Ray Jones 10db95733f Added external thermostat via GPIO in 2. Want to change how GPIO pins are defined.
Modded code to only allow single DS18B20 - getting funny ROM SEARCH lock ups...
Set mini temp sample interval to 750ms, as per data sheet for 12bit DS18B20
2019-08-07 18:59:30 +10:00
Ray Jones 1c314e14f2 removed debug prints of TempCurrent - grrrrr 2019-08-04 08:23:54 +10:00
Ray Jones 2a788cb2d0 Fixed rounding issue of TempCurrent in JSON data, always 0.1 low 2019-08-04 08:19:59 +10:00