Added trap for skipping directly to suspend if already over temperature with cyclic mode enabled.
Otherwise heater starts then runs stop cycle immediately!
This commit is contained in:
parent
1c314e14f2
commit
e205119b24
|
@ -148,6 +148,7 @@ bool validateFrame(const CProtocol& frame, const char* name);
|
|||
void checkDisplayUpdate();
|
||||
void checkDebugCommands();
|
||||
void manageCyclicMode();
|
||||
bool preemptCyclicMode();
|
||||
void doStreaming();
|
||||
void heaterOn();
|
||||
void heaterOff();
|
||||
|
@ -882,6 +883,24 @@ void manageCyclicMode()
|
|||
}
|
||||
}
|
||||
|
||||
bool preemptCyclicMode()
|
||||
{
|
||||
const sCyclicThermostat& cyclic = NVstore.getUserSettings().cyclic;
|
||||
if(cyclic.Stop) { // cyclic mode enabled, and user has started heater
|
||||
int stopDeltaT = cyclic.Stop + 1; // bump up by 1 degree - no point invoking at 1 deg over!
|
||||
float deltaT = getTemperatureSensor() - getDemandDegC();
|
||||
|
||||
// check if over temp, skip straight to suspend
|
||||
if(deltaT > stopDeltaT) {
|
||||
DebugPort.printf("CYCLIC MODE: Skipping directly to suspend, deltaT > +%d\r\n", stopDeltaT);
|
||||
heaterOff(); // over temp - request heater stop
|
||||
return true;
|
||||
}
|
||||
}
|
||||
return false;
|
||||
}
|
||||
|
||||
|
||||
void initBlueWireSerial()
|
||||
{
|
||||
// initialize serial port to interact with the "blue wire"
|
||||
|
@ -915,8 +934,10 @@ bool validateFrame(const CProtocol& frame, const char* name)
|
|||
void requestOn()
|
||||
{
|
||||
if(bHasHtrData && (0 == SmartError.checkVolts(FilteredSamples.FastipVolts.getValue(), FilteredSamples.FastGlowAmps.getValue()))) {
|
||||
heaterOn();
|
||||
RTC_Store.setCyclicEngaged(true); // for cyclic mode
|
||||
if(!preemptCyclicMode()) { // only start if below cyclic threshold when enabled
|
||||
heaterOn();
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
|